Models > MHE10RXB0

MHE10RXB0 Roper Microwave - Overview

Get Parts and Repair Help for MHE10RXB0

If you know the microwave repair part you need, you can browse the list of all parts on the MHE10RXB0, or you can search by name or part description. You can also find your part by where it is located on the MHE10RXB0 by selecting a section below. If you’re not sure which part you need, you can narrow your search by selecting a common symptom and we’ll show you the repair parts most likely to fix your microwave. We’ve also included any installation videos we have for MHE10RXB0 parts. Installation instructions provided by other do-it-yourselfers will help guide you through your repair.

Search for parts
Keep searches simple, eg. "belt" or "pump". Need help?
$3.86

Light Bulb - 40W

Sold Individually.

$44.27

Door Interlock Switch Kit

This kit contains 2 switches - 15 Amp - 125/250 Volt with 3/16" terminals.

$51.28

Door Handle Assembly

$2.70

Cabinet Screw

This screw is sold individually.

$4.11

SCREW

$4.60

WASHER

$11.48

Grease Filter

$47.42

Door Handle Assembly

Screws are NOT included.

$51.13

Adapter - Exhaust

$21.83

DIODE

Common Symptoms of the MHE10RXB0 [Viewing 1 of 1]

Search Instructions
Keep searches simple, eg. "belt" or "pump". Need help?

Microwave worked intermittently depending on how door was closed

  • Customer: Robert from Bainbridge Island WA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 26 of 31 people found this instruction helpful
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and also took a while to ... read more

Microwave went dead while in use.

  • Customer: Keith from Georgetown TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 12 of 15 people found this instruction helpful
1. removed vent across the top to gain excess to Screw holding control in place. 2. Removed control panel to access Fuse. 3. Remover fuse after pulling plug. 4.Tested fuse for continuity with volt ohm meter noting no continuity.5. Orderd new fuse. 6. receeived new fuse and installed infuse holder.7. plugged microwave plug back in receptical and tested unit n... read more

Burned out light bulbs in microwave hood stove

  • Customer: Herbert from Norton MA
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 9 of 11 people found this instruction helpful
I had some difficulty removing the glass plate because of the awkward (upside down) position of the screw that retained it. After replacing the burned out bulbs and replacig the glass plate the problem of replacing the screw involved my dropping the thing several times before I got the screw threads to catch. I got a screw thread to catch enough to hold th... read more