M1203R LG Air Conditioner - Overview
Sections of the M1203R
[Viewing 1 of 1]Keep searches simple, eg. "belt" or "pump".
FAN,AXIAL
PartSelect #: PS12747824
Manufacturer #: 5900A10009E
The condenser fan blade fits onto the air conditioner motor shaft. The fan blade helps circulate air over the condenser to cool the refrigerant before it enters in to the evaporator. This part is beig...
$48.05
In Stock
Room Air Conditioner Installation Kit
PartSelect #: PS7784777
Manufacturer #: 3127A20074Y
The installation kit contains the hardware you need to install the room air conditioner.
$48.05
On Order
CLAMP,SPRING
PartSelect #: PS16224004
Manufacturer #: MBU64446301
The fan blade clamp, also known as a clamp spring, are for air conditioners. The clamp supports the fan blade on the motor shaft. When the motor is running, it signals the shaft to turn and rotate, bu...
$6.37
In Stock
Questions And Answers for M1203R
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Symptoms of the M1203R
[Viewing 1 of 1]Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broken fan axial blade
Unscrewed the unit from the exterior case pulled out the unit unscrewed the 4 screw that hold the fan shroud carefully unscrewed the coil pulled back unclipped the axial fan clip gentlyhit with rubber mallet replacement of new fan replaced clip
15 minutes best investment of 20 bucks as apposed to 400 $
15 minutes best investment of 20 bucks as apposed to 400 $
Parts Used:
-
John from HARLINGEN, TX
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
6 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
window a/x unit fan broke
took apart the fan housing and replaced the fan saving me hundreds of dollars from buying a new unit
Parts Used:
-
margaret from CARRIERE, MS
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers
6 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor mount broke due to imbalance caused by mud dobber nests.
Pulled PTAC out of wall sleeve, unhook wire harness from control area, remove condenser shroud and motor and fan blade all at the same time. Replaced motor bracket and re-installed in reverse order.
Parts Used:
-
Travis from LOUISVILLE, IL
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!