If your air conditioner is not blowing cold air, the problem may be in the capacitor. If the capacitor fails, the compressor will not start and the fan will only blow warm air. The compressor and capa...
Remove the main power disconnect. Remove the top cover and the fan-side side panel. Disconnect the thermister from the main circuit board located under top panel. Remove the two thermister sensors from the holders attached to suction piping. Install the new thermisters and reconnect the harness to the circuit board. Reinstall top cover an
... Read mored side panel. Reinstall main power disconnect. Verify that error code has cleared. Operate the system normally.
Download PDF Multi Air Conditioner SVC Manual for LMU187HV,,, Disconnect the Power,,, Remove cover of the Outdoor Compressor, Remove black cover to the electronics board.. Find the Red Plug-in to the existing Suction Pipe Thermistor, replace with the new one, match each sensor (2) follow the leads one by one, remove the old attach the new
... Read more ones... Replace covers then the Disconnect & Waa-Laa,,, Fixed