Broken tab that holds the pantry door on

  • Customer: Craig from Pueblo CO
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 5 of 6 people found this instruction helpful
I broke the left side end cap the holds the pantry door on.
I search the internet for the part and happened to run across part select. I order the part and received the part with in 3 business days. It took less than 30 minutes to replace the end cap.

The great reviews help me with my choice to order the part from part select. I will order parts from them again.

Thanks for helping me fix my fridge.

I put my frig. outside on my deck during a kitchen remodel and when I brought it back in a hooked up the water line again, I solenoid fill valve on the back of the unit leaked badly. I found a big crack in it and guessed it must have had a bit of water left in it when put outside in sub freezing, w

  • Customer: Jonathan from Plymouth MA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 5 of 6 people found this instruction helpful
I searched in line for a replacement fill valve and easily found it on your site w/ excellent diagrams. I turned off the frig., & the part came out simply and logically first removing the 5 screws that hold it in w/ a nut driver. Then remove the supply water line and the other quick connect lines that feed the ice maker and the chilled water dispenser. Then, disconnect the two wire harnesses that clip off easily by hand. They feed the two relays in the valve and are color coded. Remove the valve and reverse the procedure to hook it back up. Note: a little water will come out of the lines so be ready w/ a small bowl and a dish towel. After installing the new part, it was necessary to "bleed" the water lines of air by drawing a few glasses of water from the water dispenser to get the system operating normally again. One tool, common sense, 30 minutes. Probably saved $150 + on a repair man plus parts markup. Thanks very much!!

Pin for lid broke 2 Liter of pop fill on it

  • Customer: Tommy N from Tipton IN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 5 of 7 people found this instruction helpful
Removed drawers and glass top and support bars Two screws on slid bar two screws on end cap, Make sure you take time to remove air control it has two pivot points with small taps.
Then just replace parts as you had taken off very easy.

No ice or cold water from dispenser

  • Customer: RENE from SHERIDAN OR
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench(Adjustable)
  • 5 of 7 people found this instruction helpful
Diconnecting the hoses was a pain as there are no instructions. Draw a diagram of each hose and color of the connectors or better take a picture before starting. Make sure the water is off, have a bowl & towels ready to mop up the water that runs out of the hoses. You have to push each hose in along with the little top hat connector that the hose runs thru. With both pushed in, hold the top hat connector down and pull the hose up and out. I could not reconnect without a leak on the hose that has a spring in it if I slipped the hose thru the white bracket. I ran the hose outside of the bracket and it went right in with no leak.

Ice maker leaked water

  • Customer: Robert from Pennsylvania Furnace PA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 6 of 10 people found this instruction helpful
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.

didn't eject icecubes

  • Customer: Ronald from Marion IL
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 5 of 7 people found this instruction helpful
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin

Ice maker just stopped making ice

  • Customer: Thomas from Valencia PA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver
  • 4 of 4 people found this instruction helpful
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.

The ice maker stopped making ice.

  • Customer: Thomas from Cupertino CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 4 of 4 people found this instruction helpful
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.

Drain pan failed and had many leaks

  • Customer: Malcolm from Parrish FL
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 5 of 8 people found this instruction helpful
Took two times getting the correct part, however after getting the correct part it took about 10-minutes to replace. Had to take the fan out. When you put the new drip pan in make sure it is positioned so that the guides on the pan aligns with slots in the bottom refrig brace, otherwise back pannel will not align correctly. The fan is very easy getting aligned in the new tray. May take a little effort. I do not know why the pan on a refrighterator that is less than 5-years old could start breaking into many pieces.

My old icemaker lost some of the nonstick surface and the ice didn't want to come out

  • Customer: Thomas from Ruth MI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 4 of 5 people found this instruction helpful
I unhooked the wire harness from the ref. and took out three screws and pulled the old unit out. I than changed a few parts from the old icemaker to the new and reattached the new ice maker to the ref. and plugged the wire back in. everything is working fine. No problems. Also I was very happy with the ordering process. Thank you!!

Replacing the bulb in the freezer side

  • Customer: Yafa (and David) from Bothell WA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 4 of 5 people found this instruction helpful
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.

Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.

Center Crisper rail was broken and the drawers were not closing all the way

  • Customer: Edward from Lowell MA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 5 of 8 people found this instruction helpful
Just pulled out theold and squeezed in the new. I forced it and it went in.

Icemaker would not fill with water.

  • Customer: Linford from Cedarville NJ
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 5 of 8 people found this instruction helpful
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.

Glides easy to install, about 15 minutes

  • Customer: Mary Sue from Tinley Park IL
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 5 of 8 people found this instruction helpful
you need to take the deli drawer out, make sure your flat head screw driver is large enough for the head of the screw as screwing into the plastic is a bit difficult. Other than that there are 2 screws and its pretty easy.

ice maker stopped making ice

  • Customer: ROBERT from FLAGLER BEACH FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 9 of 20 people found this instruction helpful
I loosened the two top screws, removed the bottom screw, lifted up on ice maker and slid it off, unplugged the wire from refrig. I transfered the wire to the new icemaker, pluged it back in, placed it on the two screws, installed lower screw, tighten top screws. Total time spent less than 15 minutes. The ice maker cost $125.00 with freight. Sears wanted $374.00