Microwave wouldn’t shut off when door was opened
Followed the online videos to enter the cavity to the switch holder. Noticed right away the dreaded capacitor was in back right corner behind where the touch pad had been removed. I isolated the capacitor with an old computer mouse pad for extra safety. Took some manipulations to get the switch mount out from behind the wire bundles. Once out front, easy to use small flat blade screwdriver to release each switch and replace with matching new switch. Only one switch was bad but replaced all three. Back together and working great.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • John from POWHATAN, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would run when door is opened
Two screws to remove upper from vent. Two screws to remove the didgit panel lift ip to remove and put aside remove the two screws that hold the door sensors. Depress the tab to remove the defective sensor disconnect the electrical connector and replace the new sensor snap it back into the holder install the two screws, install the didgital panel and vent panel to complete the job. Please be aware that there is a video of this procedure on Y tube
Parts Used:
Monitor Door Switch
  • Ernest from RIVERSIDE, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
2 rack holders broke
used the Dremel Osciilating tool with small blade to quickly cut/remove the old rack holder and then inserted new hold. Took less then 5 minutes total.
Parts Used:
Rack Holder
  • Nick from Edison, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
stove Lights on bottom of microwave burned out and glass cover broke
Just unscrewed the screw holding the cover in place, removed the broken glass wearing gloves and then removed both of the burned out lights. Replaced the bulbs while wearing gloves to avoid the commone problem of contaminating the halogen bulbs during installation which can shorten their life. Replaced glass into cover bent back short tabs to hold the glass in place and closed the cover. Reattached cover with screw and it was done 15 minutes tops
Parts Used:
Halogen Light Bulb - 120V 20W Glass Light Lens
  • Andrew from Park Ridge, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked Microwave Glass Plate
Odered replacement
Parts Used:
Glass Cooking Tray
  • marielen from newport, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lens Was Not Sized To Fit And Was Left Extremely Sharp
Had to take to a local glass shop for sizing and to remove sharp edges. Will never order again.
Parts Used:
Glass Light Lens
  • robert from salmon, ID
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave Rack Holders (Little plastic pieces) Broken
Found your site online, ordered parts needed. When parts arrived I just put them into the holes in the microwave and popped on the self. Worked like a charm! Thanks very much!
Parts Used:
Rack Holder
  • Janice from Summerville, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
6 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light burned out
removed screw that holds glass for light and replaced bulb.
Reinserted screw that holds glass.

Only down side was cost to ship small bulb.
Parts Used:
Halogen Light Bulb - 120V 20W
  • James from Orient, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Vent over top of microwave wouldn't close
I found the replacement parts by the drawings on the website. The drawings are excellent and very easy to follow. Ordered what I needed and read the previous comments to see how to dismantle the vent and replaced the part. It was slot simpler than expected. Thanks to part select for a great experience.
Parts Used:
Vent Grille Frame Grille Hinge - Left Side Grille Hinge - Right Side Louver Spring
  • Ronald from Murphys, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
6 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Halogen lamps did not light-burned out
Removed the light cover screw with a Phillips screwdriver. Removed the lamps from the packaging just enough to free up the 2 prongs for fitting in the socket. Make sure the power is in the "off position". Install the bulbs one at a time by lining up the 2 sockets (Very important not to touch the halogen bulb glass surface while installing them). Energize the light switch to check operation of the new bulbs.
Parts Used:
Halogen Light Bulb - 120V 20W
  • dennis from harbor springs, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
needed light bulb
The halogen light bulb took a little skill. The prongs were a little difficult to maneuver into place.
Parts Used:
Halogen Light Bulb
  • Susan from VAIL, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When door opened, microwave would turn on
Removed the outer cover to access the door switches. Turns out there were three switches, but I determined that only two were bad. When the small colored tab on the switch is pushed in it should make a clicking sound. The two bad switches had no resistance and did not make any noise when pressed. Removing the switch is relatively easy, you simply pull it away from a couple small tabs holding them in place. After reconnecting the wire leads, insert back into the holding tabs and install the cover.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • Tom from SUN PRAIRIE, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The microwave turntable rotates when the door is open.
This is sometimes described in other repair notes as "microwave 'runs' when door is open."
With power disconnected: Remove the microwave's metal grill surround. Three lower screws accessible with lower oven door open. Two screws accessible at top of microwave door opening with door open.
Remove microwave control panel: Remove two femaleTorx head screws (#27?) that secure the panel, accessible at right side of door opening. The right side of the control panel is secured by plastic tabs fitting into slots in the oven frame. Take good care to note how these tabs disengage from the slots (lift and shift). Tab breakage very possible! Once disengaged, the panel hinges outward and downward and is self-supported. It may be necessary to guide some of the wiring out of the way to fully lower.
There are three door switches, one "monitor" and two "secondary" switches. All switches are housed in a plastic frame, which must be lifted out of position for access, each switch is retained by flexible plastic, breakable-looking hooked fingers. Also note that the electrical connectors have tiny release tabs that must be depressed in order to pull them off of the switches. In my case the topmost switch, one of the "secondary" switches, was clearly bad since there was no "snap" or click when pressing the switch's button. Maybe you can determine which switch is bad before proceeding but I had ordered all three to avoid going through this exercise again any time soon.
Replace switch or switches, place switch carrier back into position and otherwise reverse the disassembly steps.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • DeWitt from Boulder, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Parts Used:
FUSE
  • Ronald from PONCA CITY, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Still runs even the door was open
Pulled it from the wall remove the front vent covers removed the control panel remove the door switches by a special screw driver bit which looks a star remove the electrical terminals pressed the plastic clip pulled the switch replaced it with new one then followed initial steps backward
Parts Used:
Monitor Door Switch Secondary Door Switch
  • Erwin from CONROE, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the JVM2070SK02
76 - 90 of 189