Converted an over the range microwave from non vented ductless to outside vent.

  • Customer: Emanuel from Woodstock VA
  • Difficulty: A Bit Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Screw drivers
  • 0 of 0 people found this instruction helpful
Installation of the damper was effortless but removing the microwave, cutting holes vertically through an overhead cabinet then installing ducting with a ninety degree bend, through another cabinet, and then through outside wall consumed most of the time and effort.Your service, packaging, and timely (next day!) were extremely helpful.

Door handle broke off at bottom

  • Customer: James from Surprise AZ
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Pliers, Screw drivers
  • 0 of 0 people found this instruction helpful
First, if this happens to you,"DON'T TRY TO SUPER GLUE THE HANDLE BACK ON." Had I not done that repair would have only taken 30 minutes and that would be without knowing what I know now. Very easy repair. Remove upper screw,.Remove the the frame from around the inside of the window which will expose the lower screw. Be gentle as it fits tight and snaps off and back on. Put new handle in place and screw down until handle doesn't jiggle, don't over tighten. Replace inner window frame, it just snaps into place. You are finished. I ordered replacement screws also, they were not needed but I felt that $3.50 was cheap insurance in case they needed replaced.

Light out and socket broken

  • Customer: Charles from Alvaton KY
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 0 of 0 people found this instruction helpful
Fist I removed the 5 screws under the microwave. Then I dropped the panel and accessed the socket. I removed the socket by removing the one screw and disconnecting the wires. Replaced the wires on the new socket, installed the new bulb and reattached with the screw. replaced the panel with the 5 screws and I was done. Easy

Microwave fan would run when opening the door. Evenutally the mircowave would not run, but the electrical panel was still working

  • Customer: Julie from Elm Grove WI
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 0 of 0 people found this instruction helpful
Opened the microwave oven door, unscrewed two screws which held the control panel on, then I removed two of the door switches (each had two screws), and then used the continuity tester to see which one was not operating. It turned out to be the secondary door switch, replaced it and to my amazement, the microwave worked. I have never repaired an appliance before but I didn't want to replace our over-the-stove built in microwave. It was the best day ever when it was working again! The hardest part was getting myself to try the repair.

change microwave fan discharge from front to top

  • Customer: James from Newbern NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 0 of 0 people found this instruction helpful
damper plate was a snap-in part. rotated fan discharge to top of microwave. installed ducting to discharge food odors outside.

When opening door the microwave would turn on.

  • Customer: Clarence from Rocky Ridge OH
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 0 of 0 people found this instruction helpful
Watched How to repair a Microwave that turns on when the door is opened Video on the web. From this took a shot at the switch was the problem. When I removed the switch it was defective. The small button was in and when you turned the switch upside down the button would drop back into position. Ordered a switch for $25.oo , installed it and the microwave is working fine.

Bulbs blew and disintegrated when removal was attempted

  • Customer: Richard from Santa Maria CA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 0 of 0 people found this instruction helpful
Unplug appliance, Staring from the rear sides, remove the four side screws. Remove the left and right front screws and finally the front center screw. The bottom panel hinges down toward the rear . Unplug the input wires from the sockets . Unscrew the two retainer screws (one each) and pull the sockets out of the panel. Note that the retainer screws are shouldered. The shoulder fits through the elongated slot in the socket. Screw the bulb into the socket and insert through the mounting hole. Insert and tighten the mounting screws. Note that the sockets may appear to be a bit loose. That's OK because of the shouldered screw. Don't over tighten or you risk stripping the threads of the panel. Plug in the input sockets and install the panel screws in the reverse order of removal. Plug the appliance in and test the bulbs.

Surface light bulbs burnt out and heat welded to sockets

  • Customer: David from Lady Lake FL
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Screw drivers
  • 0 of 0 people found this instruction helpful
Since the job required replacing both the bulbs and sockets the unit was dropped from the wall. Used a towel and plywood to protect the range under the unit. Then these steps: Unplugged the power cable and placed a support board under the unit while removing three bolts from overhead cabinet. Next, removed support board and with a helper rotated the unit down and lifted it out of the rear wall mounting panel. Then turned the unit upside down, removed the bottom plate and unplugged the feed wires and two wires to each of the sockets. Next the single screws holding the sockets were removed and the sockets extracted from the mounting shells and new units were installed. When remounting the unit it was necessary to start all three bolts from the upper cabinet just a few turns and then tighten the center bolt completely first.