turntable erratic and noisy
Removed 6 screws from bottom cover and 2 from motor cover. Unplugged motor and installed new motor. Plugged in new, Installed cover. Done
Parts Used:
Turntable Motor - 60 Hz.
  • michael from montgomery, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven would not start when closing door.
Removed some cosmetic panels. Removed the assembly with micro switches. Examined the faulty switch by checking the clicking action of switch. Two others were ok by this method. Replaced the switch with new one. Works fine so far. Thanks to web site and YouTube videos.
Parts Used:
Micro Switch
  • Raymond from DEPEW, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the turn table no turn and no heat the food. but the bottom oven worked
well I unplugged the microwave one day prior to working on it. shock precaution smart way to do this job. very easy pullout the screws behind the unit pull off the outer casing. minor screws inside the unit you have to remove a couple things out of the way. unplug the magnetron and remove first gives you more room to work on the side panel to replace the micro switches. I only replaced one the bottom micro switch. only one bad, but since I was in there I clean the bulb and changed the magnetron any ways. I read other reviews and made my choice to do so. it works perfectly now. Thanks PartSelect for having parts.
Parts Used:
Magnetron Micro Switch
  • mark from SANBORN, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not heat and made a buzzing or popping sound
Unplug the microwave. Remove the Philips head and safety Torx head screws along the bottom of the sides and rear of the microwave which hold the black cover on. Lift the cover up at the rear and slide it backwards to disengage the tabs on the front top. Remove the cover. Discharge the capacitor by shorting the terminals to each other and then ground. Do this with a well insulated object and be aware there may be a pop when you do this. Keep hands, etc. on the insulated part of the object (screwdriver handle, etc). There's a lot of stored energy in that capacitor. I'd advise first checking the diode to make sure its not bad. Replace it if it is. The Magnatron is held in with a couple of screws on the top and sides. Unplug the connector and remove the screws. Remove the Magnatron. Installation is the reverse of removal.
Parts Used:
Magnetron
  • Thomas from NEWARK, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Glass Cooking Tray Broke
Opened Box and Replaced Part......No Problem!
Parts Used:
Glass Cooking Tray
  • Mitchell from Henderson, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave not heating
removed a dozen screws-discarded large cap-replaced diode-replaced a dozen screws(took longer to replace them than remove for some unknown reason). Microwave now works(wife happy).
Parts Used:
Black Sleeve Diode
  • Mark from GREENSBURG, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave Oven Light Burned Out
There were two hard parts for me to work through.

The first was breaking off the two screws that need a special head screwdriver to remove. None of my special special head screwdrivers worked (I have a few), so I used a hammer to force them off.

The second hardest part for me was finding the correct replacement bulb on-line. My Amana Microwave is a combo Microwave/Convection type, and it's a strange little bulb - almost tube like.

Once I did find the right bulb on this PartSelect.com website it was a breeze. The part was delivered in just a couple of days (even during this Covid-19 pandemic). Once I had the replacement bulb in hand it barely took 5 minutes to install.

Thanks PartSelect!!
Parts Used:
Light Bulb
  • Norbert from BROUSSARD, LA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave Timer would count down, but unit would not heat. Turntable not turning.
Replaced entire door latch assembly with the three micro switches. Easier to replace entire latch assembly as individual switches do not remove easily from latch assembly. Had trouble removing front panel assembly. Parts ordered solved this problem.
Parts Used:
Micro Switch Micro Switch
  • William from CLERMONT, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave oven ran but stopped heating
I had to unmount the over-the-range microwave oven to be able to gain access to the interior of the oven. Complicating removal (and re-installation) was the fact that there is a "pot-filler" faucet installed directly underneath the oven. In retrospect, I should've removed the faucet before doing the repair, but "c'est la vie."

After I got the microwave down, removing the case was also "interesting." I get bonus points for the fact that the previous owner must've had to replace the same diode before - and then re-assembled the microwave case incorrectly - thereby adding to the confusion (BTW, the service manual that I found online said nothing about how to remove the oven's case).

To remove the case, undo all the screws holding it on, and then rotate the case upwards from the back while also pulling the case backwards. There are crimped folds on the inside of the case that mate with the back edges of the front of the oven's chassis, and these folds have to be unclipped from the chassis in order to remove the case.

Replacing the diode itself was the easiest part of the job. The two connectors on the diode are of different types, making it impossible to install the diode with the wrong polarity.

BTW, the diode that had failed was not an OEM diode; I suspect it was a generic component that had been installed by a repairman sometime between 2004-2008 (when our home's original owners still owned the home). On the other hand, the new diode from PartSelect is an OEM part (it came packaged in a sealed Whirlpool bag).

The fact that the oven had stopped heating indicated that it was either the high-voltage diode or the magnetron that had failed. Since a replacement diode costs ~ 1/10th as much as a replacement magnetron, I figured it made sense to replace the cheaper part first. Fortunately, this fixed the problem.

One last thing: I tried testing both the old and new diodes for conductivity and polarity using my volt-ohm meter (VOM), but I was unable to get either diode to "turn on," even though my VOM is powered by a 9-v battery, and I used the 2-Mohm range setting. I guess the test voltage of my el-cheapo VOM isn't high enough to exceed the diode's threshold voltage, (even though I have successfully used this same VOM to test low-voltage diodes).
Parts Used:
Black Sleeve Diode
  • Forrest from Eugene, OR
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Bulb Out.
1. Order correct light bulb for unit and have it with you before removing old lightbulb.
My Microwave is built into cabinet.
2. Disconnect power (Either turn breaker off or unplug unit from wall)
3. Remove face cover on cabinet. (4 Phillips head screws)
I was able to reach in the opening in the cabinet and unplug from the wall.
4. Remove Phillip head screws holding microwave in cabinet.
5. Remove microwave from cabinet.
6. Remove Phillip head screws and torx screws holding outside cover on the back of unit and the side (1 on right side) and then remove cover.
Light bulb is on the top front right side.
7. Remove 1 philip head screw holding light bulb and unplug quick connector wires.
8. Plug quick connector into new light bulb same way it came out and place new light bulb in place and put the 1 philips head screw holding it back in place.
9. Put cover back on and all the screws. Temporary plug the unit in to test light bulb works before securing it back into cabinet.
10. Reverse order 5,4,Plug unit in wall before putting the face back on.
Done.
Parts Used:
Light Bulb
  • Mason from SUTTON, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No power to any microwave functions
Access is via RT. SIDE Panel as you face microwave. There are three screws on the bottom right edge to loosen. After that the side panel slips down and off. the fuse is located in the rear near where the power cord comes in. It is the white ceramic tube 1/4" in dia. and 1-1/2" long. Pull it out like any fuse and replace with new one. Reassemble and you are done!
Parts Used:
Ceramic Fuse - 20 amp
  • Richard from CALIFORNIA, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Tray got chipped on the corner
ordered a new tray
Parts Used:
Glass Cooking Tray
  • Mary Lee from LK FOREST PK, WA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave dish would not move back and forth
unscrewed the bottom of the microwave and unplugged old part then took the screw out and put new one in. Super easy!
Parts Used:
Motor, AC Synchronous
  • Susan from HENDERSON, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not start
Watched a you tube video prior to installing new switch. Followed the video which gave me confidence i was up to the task. After removing the touch pad I found my design was not exactly like the you tube model but I found the defective switch, replaced it and put the microwave back together. Works great. Again watch the videos
Parts Used:
Door Interlock Switch Kit
  • LENNARD from BURNSVILLE, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dead Light bulb
Required that i remove the built in frame and mounting. Required tamper proof socket to remove housing. I removed the old bulb and simply replaced and reverse installed the cabinet.
Parts Used:
Light Bulb
  • Andrea from Rockwall, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
5 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!