If you know the microwave repair part you need, you can browse the list of all parts on the JMC8100ADB, or you can search by name or part description. You can also find your part by where it is located on the JMC8100ADB by selecting a section below. If you’re not sure which part you need, you can narrow your search by selecting a common symptom and we’ll show you the repair parts most likely to fix your microwave. Installation instructions provided by other do-it-yourselfers will help guide you through your repair.

$6.19

Bulb - 120v 25w

$3.22

Ceramic Fuse - 20 Amp

This ceramic microwave fuse is white in the center, while each end is made of metal. This is a twenty amp fuse.

$2.70

SCREW

$3.83

SCREW

$2.77

SCREW

TURNTABLE

$74.23

CAPACITOR

SCREW

$20.44

SWITCH- PR

RECEPTACLE, BULB

Common Symptoms of the JMC8100ADB [Viewing 1 of 32]

Search Instructions
Keep searches simple, eg. "belt" or "pump". Need help?

Blows main fuse when the microwave generator start, (cooking function).

  • Customer: Jay from Edwardsville IL
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 24 of 30 people found this instruction helpful
Remove microwave from oven cabinet. remove cover and check main fuse with ohm meter.
Tried fuse, it does not blow untill cooking starts.
Check capacitor with ohm meter, after properly performing capacitor dischagre procedure.
Order new capacitor, simple installation. another new fuse and all is good and cooking again. read more

microwave oven blew fuse

  • Customer: tad from tamarack MN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 16 of 22 people found this instruction helpful
First I removed upper front grill by removing two Philips head screws on top and pulling off. This exposed the Philips head screw which holds control panel in place. After removing screw I pushed up on panel and it came off to expose fuse. With needle nose pliers I removed old fuse and again with pliers held new fuse in position. With the help of a bladed s... read more

microve stopped working

  • Customer: Denice from Montgomery AL
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required:
  • 8 of 14 people found this instruction helpful
Jenn-Air Microwave would not turn on. Clock worked , light worked, timer worked and would count down .I changed' Part #0813140 Switch, Micr} cost $8.99 plus shippingNow it works Thank You for good advise read more