Ice maker leaking at first then quit making ice all together

  • Customer: Hootie from Joshua TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 370 of 378 people found this instruction helpful
unplugged refrigerator and shut off water, removed one screw and loosened two more, after removing one side of the ice bucket rail, unplugged electrical from old ice maker. Then I removed the bail and out on new one, reinstalled ice maker in reverse order from taking it out.

Water overflowed ice maker turnning ice bucket into solid mass of ice

  • Customer: Harry from Grand Ledge MI
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 185 of 255 people found this instruction helpful
My ice maker has been shedding its non-stick coating for over a year. Within the last month of so, it started pouring water into the ice bucket below, turning it into a solid mass of ice. So I purchased a new ice maker assembly. I encountered two problems not mentioned in the 21 or so do-it-yourselfer repair stories that precede this one. First problem: one of the three screws that hold the ice maker to the refrigerator wall is hidden behind the large (black) end of the ice maker and is difficult to access. Before trying to replace the ice maker, make sure you have the physical dexterity to remove that screw. Second problem: it is not apparent how to remove the wire harness that plugs into the ice maker assembly. BEFORE you can remove the wire harness, you MUST remove the large white cap that covers the black end of the ice maker assembly and then push in a retaining tab to release the wire harness. If you don't do this, the wire harness will not release. Other than those two problems, it was relatively easy to remove three screws, unplug the wire harness, transfer three small, metal parts from the old ice maker to the new, plug in the new wire harness, mount the ice maker assembly so that the water tube is in the proper position, and then re-install the three screws. The ice maker works fine now. (P.S. I was told by an expert that the real problem might be a malfunctioning fill valve. I would have replaced the fill valve if replacing the ice maker assembly had not fixed the problem.)

The compressor would not run.

  • Customer: Gilbert from Clinton MO
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 146 of 164 people found this instruction helpful
I removed the screws in the lower back panel where the compressor is located. Then I unplugged the capacitor and plugged the new one in. I then checked to see if the compressor would start. It wouldn't so I replaced the overload relay with capacitor and that fixed the problem. The capacitor just plugs into the relay then plugs into the compressor. There are several screws but all in all it is easy.

Freezer is cold, Refridgerator is not as cold as it should be

  • Customer: Russell from Hardinsburg KY
  • Difficulty: A Bit Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Screw drivers
  • 143 of 170 people found this instruction helpful
Having seen this problem before in other equipment so I had an idea where to look. Problem: the automatic defrost function was not operating. Looking through openings in the back panel of the freezer compartment, you could see the evaporator coils and fins were a solid chuck of ice. There are three logical components to check. Heater element, thermostat (located just above the evaporator) and a relay on the control board (located in the fridge control panel). Checked the heater with an ohm meter -- OK. The thermostat closes the circuit at around 20 degrees and opens at around 32 degrees. Pulled out the thermostat, wiring, fan unit. Everything unplugs, unscrews, and unclips, don't cut wires. Put the whole assembly in a friends freezer for an hour or so to see if the thermostat closes -- OK. Problem had to be with the control board. Replaced control board, reprogrammed it per included instruction. Everything is working again.

Removing the existing filter by rotating as directed and then dislodging from 'docking' station proved difficult. Turns out, the old filter is under a bit of vacuum pressure and getting the unit to separate or release was a challenge.

  • Customer: Jake from Novato CA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 168 of 251 people found this instruction helpful
I removed the drop-down outer housing by gently prying the sides of the two pivot pins at the rear. This gave me move 'room' to grip and slightly rotate then pull the old filter forward and away from the tight suction connection. I was concerned that I would be too forceful for the plastic assemblies and would break something; deliberate motions and a steady thought process on the problem helped disengage the darned old filter!

Needed to change water filter in refrigerator

  • Customer: Marilyn from Lilburn GA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 116 of 188 people found this instruction helpful
The switch-out of the water filter was simple with good instructions on the box.
The part was delivered very, very quickly!

water filter needed replacing

  • Customer: Kathryn from Cedar Springs MI
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 78 of 81 people found this instruction helpful
I unscrewed the old one and replaced it with the new one. The real benefit was I got the exact part I needed w/o a 30 minute drive and sales people that ignored me. I had gone to the local store the day before and come home with the wrong part because i could not get assistance and the part # I had did not match what was labled on the package. I used the same part # on the website and got exactly what was needed, less that 48 hrs after I ordered it. thanks for the prompt service. we will be a repeat customer

defroster mode was not working causing freezer to ice up and refrigerator to be warm. Also fan was running continuely

  • Customer: James from Welches OR
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 70 of 78 people found this instruction helpful
The hard part for me was figuring out which part was causing the problem. I read what others had done and followed their test methods. I checked the defroster heater for continuity and the defroster thermostat to make sure it was closing. the defroster termostat has to be cold to check it. You will need to check it while it is in ice or take it out and put it in another freezer for 30 mins and then check it for continuity. Those items checked out ok so it had to be the control board. The control board is a 5 min job to replace but making sure that is your problem is the hard part. I think the control board was bad due to a power surge we had when the power went out and came back on. It might be a good idea to put a surge protector on your home to protect your fridge and all your other electronic stuff. Our refrigerator is now working like new again. Thank you for all your help, Jim

Top unit was not getting cold

  • Customer: Gregory from Lexington SC
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 68 of 73 people found this instruction helpful
First thing to do is take two screws off where the door closes.I removed the light sheild off by pushing it to back of refrig.The most hardest part is removing the complete panel,I took a small flat blade scraper to ply down to get small access than you need to put alot of pressure to start getting the panel to start coming off there are alot of pegs to free,the back panel has two hinges that slide towards the front.Once the panel drops remove the connectors and take entire unit out,very easy to replace the control board at this point.Installation is easy slide the two hinges on back in place and put pressure on unit to snap entire unit in place.Program unit with paperwork that came with part very easy to do.Frig is working great now.Just a note the paperwork on refrig is located in the front right corner the mf hids it ,this information will allow you to check all problems with refrig using the key pads for freezer/refrig.Good luck.

The refrigerator was not getting cold and the coils were not defrosting.

  • Customer: Cheryl K from Pinellas Park FL
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 51 of 57 people found this instruction helpful
Start by removing the freezer door and inner baskets so you have some space. Next, take out the ice maker by removing the 3 screws that attach it to the side and unplug it from the harness. Then the cover for the thermistor and the fan vent should be popped off carefully leaving the back cover only. The back cover is held on by 4 screws, one in each corner. Remove all 4 screws and carefully loosen the back cover by pulling the top forward and laying it level to pull it out. Behind the cover are the coils and other components. If the coils are covered with ice they should be defrosted by using a blow dryer. Once the ice is clear, the thermostat is located towards the top left clamped onto a copper pipe that circles up and around. Carefully pull it off the pipe and cut the wires making sure you leave enough to reattach the new ones with a butt connector. Strip about 1/4 inch of insulation off the wires and crimp both ends into the butt connector making sure they are tight. Heat shrink is highly recommended. Clamp the new thermostat to the copper pipe where the old one used to be and your almost done. Replace the back cover the opposite of the way it was pulled out by putting it in flat with the bottom part in front. Once it is all the way to where it needs to be, push the top upwards while sliding the bottom downwards, then push it in flat against the back. It can be bent slightly if needed. Put the screws back in that hold it on and replace the plastic covers. Then reinstall the ice maker being sure the hose for the water is correctly positioned so that the water goes into the ice maker. Turn it back on and put the baskets and door back on and you're done.

easy and quick

  • Customer: alvin from irmo SC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 79 of 144 people found this instruction helpful
unscrewed to removed old and screwed in new

Trickle to no water from dispenser / very little ice

  • Customer: Salvador from McAllen TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 46 of 53 people found this instruction helpful
Shutoff water and turn off fridge. Remove the main water hose from the fridge with pliers, then remove back bottom plate of fridge where the hose was at (about 5 screws) in order to disconnect the hoses going into the valve by pushing in on the plastic colored fastener(blue & white) while pulling on the hose at the same time. Do this for each of the hoses. Then disconnect the wires from the valve and unscrew the valve(1 screw) from the back plate. Replace with new valve which comes with brand new fasteners for the hoses so all you have to do is insert the hoses in the valve and reverse the above process to install the valve.

not making ice

  • Customer: Pat from Dallas TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 45 of 51 people found this instruction helpful
Installed new ice maker. It was easy - loosen two screws and unplug old wire harness. Put new unit in place. Did not realize new unit would not come with wire harness, but transferred old one to new ice maker (easy) and, "voila" some ice in 24 hours -- much ice since then. I am a 68 year old woman and it was "sort of fun" doing this job.

The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.

  • Customer: David from Chester CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 47 of 60 people found this instruction helpful
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.

Freezer cold, refrigerator warm

  • Customer: Gordon from Ben Wheeler TX
  • Difficulty: Easy
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 60 of 101 people found this instruction helpful
Overload relay accessible from back, by compressor unit. Very easy to change out. Diagram from your site placed defrost thermostat in same area.It wasn't. Found another diagram, showed it in refrigerator light area, took that apart, not there. Yet another diagram showed it in the duct work area at back of refrigerator cabinet. Not there. Finally removed back of freezer compartment, found thermistor and thermostat with the fins. Clipped wires, wired in parts, quick fix. Longest amount of time was spent finding the old parts to replace them. Actual replacement took less than 15 minutes. Refrigerator holding at 35 degrees set on 2 now, better than ever. Total cost, less than $120, doing iy ourselves....priceless.