ice maker did not make ice
The ice maker was not getting water. I hotwired the water valve by switching the connectors for the water dispenser and ice maker water valves and water flowed into the icemaker when the water dispenser lever was pushed. I wronly assumed the water valve was good. I removed the icemaker and determined that the gear motor was not getting power in the position the icemaker had stopped.In this position, the thermostat determines when the motor gets power so I replaced the thermostat. The icemaker still would not get water! As it turns out, the water solenoid was sticking due to a deteriorated rubber washer which let the solenoid plunger get too far out of the magnetic field. I replaced the water solenoid assy and all is well. Don't get fooled by hotwiring the valve. If it isn't getting water, the solenoid probably is the culprit.
Parts Used:
Cycling thermostat
  • DAVID from TINLEY PARK, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
47 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water and ice dispenser won't shut off immediately (sticks "on")
Shut off power, removed the torx screws that hold the dispenser assembly to the freezer door, disconnected "ribbon cable" from keypad and removed the dispenser assembly to counter. Unhooked sides and removed rubber actuator pad, unscrewed limit switch, removed and disconnected 2 wires. Reversed the above with new actuator pad and limit switch. Total time about 20 minutes.
Parts Used:
Limit Switch - 2 Terminal Ice and Water Dispenser Actuator Pad Dispenser Grill
  • Roger from Northborough, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
39 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noisy fan motor
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, close up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
Parts Used:
Condenser Fan Motor Kit
  • robert from nashotah, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
37 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Plastic Tray which holds the ice depenser motor broke
The motor had broken loose from the plastic enclosure, so I first unplugged the motor from the power supply in the rear of the freezer compartment in order to remove it from the freezer. I then removed the four screws which held the motor against the plastic enclosure. I also removed the screws which hold the plastic enclosure to the freezer compartment.

The most difficult part of the repair was removing the 2 pronged fork from the shaft of the motor as it was reversed threaded on the motor. I held the motor in place on while using two pair of pliers to remove the fork from the end of the motor shaft. I used one pair of pliers to hold the shaft in place while using the other pair of pliers to turn the fitting in the opposite direction.

Once this was off, it took only 5 minutes to reattach the motor to the new enclosure and place it back into the freezer. Total repair time was about 30 minutes because I had to figure out how to get the fork off of the motor shaft. Everything else went very smooth. The new part fit perfectly.
Parts Used:
Ice Bucket Housing
  • Michael from Alpharetta, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Wrench set
27 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator warmed up and freezer became colder
After removing all shelves, I removed the 2 screws holding the 2 panels in front of the evaporator and heater. The heater is located at the bottom of the evaporator coils and is held on by a simple wire clip. After removing the heater and thermostat, is very easy to replace the new unit and reconnect the wire harness.
Parts Used:
Defrost Heater and Thermostat Assembly
  • John from Cambria, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
27 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had to replace a hose connector at the base of my refrig/frreezer
Perhaps a helpful hint:

When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.

LG
Parts Used:
Water Tube Connector/Union - 5/16 to 5/16
  • Leo from Salem, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
43 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker arm was broken
The tiny piece of plastic that holds the wire that shuts off the icemaker, broke early on with our fridge (after just a few months.) We superglued it, but last week it bit the dust for good.

Once I got this part, I removed the freezer door and trays, and pulled the icemaker out by removing 3 flathead screws and unplugging the cables. Laying in the freezer on the floor was a bit unconfortable, but not too bad.

Then I inspected the icemaker. There was no obvious way to remove the part without disassembling the front of the unit (where the motor is) to release the spindle and free the part, so I did that - 3 or 4 nuts was all that held it together. Once that was out, I removed the spindle, swapped out the part, and put it all back together and back in the freezer. Plugged it in and waited.

It took a while to start making ice. Like 5 hours. Now it's going pretty slow (much slower than before.) Haven't had time to look into it, but my suspicion is the rubber hose that feeds water into the icemaker is blocked with ice or kinked. In any case, we have ice now (but not a lot), and the unit shuts itself off properly. However, we went from having too much ice (thing never shut off) to too little (thing makes ice too slow), so I need to shoot for somewhere in the middle ;)
Parts Used:
Water Fill Cup and Bearing
  • Jason from Austin, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
32 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was a chattering Noise from Adeptive Defrost Assy
I first dropped the Cover Assy, which covers lites and controls, this was done by pulling it forward and it drops down, did not remove top shelf so It was a bit difficult to tilt cover assy. for removal. There is a srew located close to filter assy. in back use nut driver 1/4"located to remove this screw, there are then 2 screws located to the rear and side of light holders, both phillips head, the one on the left side is a bit tricky to remove but I use a thin bladed scredriver, Next there are 2 screws located on both ends od the slides that control temp, both again removed witn1/4 " nut driver, the whole upper assy drops down and forward the Adeptive Defrost assy is located in the back right corner of this assy, unplug the wires and unit snaps out, I foud it easier to pop off top cover of new unit so I could see connector assy when I reattached the wires, then replaced the top assy and snapped new unit it place, Reassymbly was reverse of removal, before placing cover assy back in place I replaced both lamps as 1 was out .
Parts Used:
Adaptive Defrost Board Light Bulb - 120V 25W
  • Herman from Hughesville, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
27 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The drive ring broke which kept the bin from despensing ice.
First I removed the screws from the front of the ice bin which freed up the drive mechanism. I then removed the drice ring and replaced it with the part from Parts Select and then replaced the screws on the front. A very simple procedure.
The chill department door was an easy snap in replacement..

I would like to add that I was very pleased with Parts Select. Locating the parts I needed was very easy and I received them the next day. When The door first broke I was told I would have to replace
the whole assembly which I was not willing to do
at a quoted price of about $350.00. Needless to say I was very happy to locate Parts Select and was very pleased with everything. I have since told family and friends about Parts Select.
Parts Used:
Chill Department Door Ice Bin Drive Ring
  • Robert from Groveport, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
24 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Parts Used:
Condenser Fan Motor Kit
  • Florentino from Windsor Locks, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
27 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Fridge wouldnt cool
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Parts Used:
Condenser Fan Motor Kit
  • Janet from Hillsboro, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker was leaking water and causing the ice to freeze into a block
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
Parts Used:
Replacement Ice Maker
  • Shelley from Katy, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
30 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Parts Used:
Condenser Fan Motor Kit
  • W from Nellysford, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Ice and Water Dispenser Would Run on After the Glass Was Removed
I am going to be completely honest here. This problem had persisted for months. I finally decided that I would buy all the associated parts and repair the unit hoping to cover the problem. Much to my surprise, after carrying out the repair, using the instructions provided by PartSelect, I still had the problem. I decided to remove and LUBRICATE the button which depresses the Limit Switch when you push a glass against the rubber membrane. Low and behold the problem was solved. The frig is nine years old, so I feel I may have prevented other problems in the future by replacing the three parts. It was a follow the directions sort of repair. I was very pleased with PartSelect response to my order (received it next day) with standard shipping.
Parts Used:
Limit Switch - 2 Terminal Dispenser Control Board Ice Dispenser Solenoid and Door Kit
  • Doug from Berkeley Springs, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
23 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would not defrost and was abnormally warm inside both compartments
The adaptive defrost assembly is located in the refrig compartment. This requires removing the panel which covers the temp controls and interior lighting. In the back right hand corner is the adaptive defrost circuit board. It has a six wire connector and is retained by two screws.

Remove the two screws and grip the connector making sure to disengage the locking tab with holds the connector in place.

Replace with the new assembly by plugging in the connector, replacing the two screws and then reinstalling the compartment cover.

Set the temperature lower than you normally would temporarily to make sure that the system is working properly (takes 30 - 45 minutes).

Once the unit begins to cool again, you can gradually readjust the temperature to it normal range in both the freezer and refrig compartments.

I used a flashlight and a mirror to check the coil in the freezer compartment for a couple of days to make sure that the defrost function was working correctly by looking up into the louvers and observing if there was any ice accumulation.

Easy repair and Partselect provided great on-line information. Also, I probably saved a bundle.
Parts Used:
Adaptive Defrost Board
  • Conrad from Northville, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
21 of 21 people found this instruction helpful.