Models > JCD2289AES > Instructions

JCD2289AES Jenn-Air Refrigerator - Instructions

All installation instructions for JCD2289AES parts

These instructions have been submitted by other PartSelect customers and can help guide you through the refrigerator repair with useful information like difficulty of repair, length of repair, tools needed, and more.

All Instructions for the JCD2289AES
76-90 of 784
Search Instructions
Keep searches simple, eg. "belt" or "pump". Need help?

The ice maker stopped making ice.

  • Customer: Thomas from Cupertino, CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 5 of 5 people found this instruction helpful
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.

Needed to replace filter

  • Customer: Phyllis from University Place, WA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 6 of 8 people found this instruction helpful
1/4 turn of old filter. it popped out. Inserted new filter, 1/4 turn and it clicked in. Piece of cake. I'm a freakin' genius.

didn't eject icecubes

  • Customer: Ronald from Marion, IL
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 6 of 8 people found this instruction helpful
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic.
Very Satisfied,
Ron Martin

Ice maker not dispensing ice

  • Customer: Travis from Westchester, CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 6 of 8 people found this instruction helpful
Removed about 6 screws. Replaced the solenoid and door kit. Replaced the screws. These parts were easy to replace. They were also super easy to identify and order from the site. I received them two days after I placed my order.
Thanks partselect.com!

ice maker chute door not working

  • Customer: DOUGLAS from MILFORD, PA
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 6 of 8 people found this instruction helpful
removed outside water spill tray and removed exterior cover & interior cover exposing the door arm and solenoid. replaced with new parts including spring. Elontronics have a plug which is easy to disconnecct. & reconnect
old solenoid head would not have fit new door arm
and vice versa.
I strongly suggest using the kit.
A Torx type screw driver is required for all screws
on the Jenn-Air

The Shaft of the Auger Drive Motor Became Stripped

  • Customer: Anthony from Amenia, ND
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 7 of 11 people found this instruction helpful
I removed the one nut screw holding the Ice bucket shelf then removed the Ice Auger Container. Then I lifed the Part containing the Drive Motor. I removed the electrical connection which just plugs into the fridge. Once the Drive motor and container was out of the fridge I removed 4 screws and the Drive motor was out. I disconnected 3 electrical connectors and connected them to the new drive motor. Then replaced the motor and connected the 4 screws. I then installed the yolk on the drive shaft and then put the drive motor container back in the fridge and reconnected the electrical. Installed the nut screw and I was done.

Fridge stopped cooling, freezer still cold... Saved $250+

  • Customer: Cory from Birnamwood, WI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 5 of 5 people found this instruction helpful
First I hired a repairman to fix it who charged $125 to defrost the cooling coils then said the defrost heater would need to be replaced for $125+labor. He had the wrong part and was going to charge me >3x the price it would have been from Partselect.com too. I figure I saved a minimum of $250 vs having him do the work then charge me yet again for the right part.

Should have just done this myself from the start and saved another $125. Information about the cause, how to test and what parts would be needed were all easy to find online once I actually searched.

Unplugged fridge.

Using diagrams from PartSelect.com and other information online anb defrosted coils with hair-dryer. (This requires removing two screws in back of freezer compartment using nut-driver to remove the panels covering coils... literally a two minute job to expose coils!)

Then found and tested defrost heater.
Defrost heater was fine. Per information online problem then had to be Adaptive Frost Control (ADA) circuit board.

In refrigerator compartment:
1) Removed top housing cover (covers lights, temp controls, etc.) This required removing a single screw (with nut-driver) attaching it to back and depressing two locking tabs near the back on either side. Slide it forward and down. The only tricky part of this repair is getting the locking tabs positioned correctly to get the plastic cover off. I did break the left one although it cover is still firmly in place in this case.)

2) Removed entire assembly from roof of fridge. involves loosening two large headed screws above lights and removing two hex-head screws with nut-driver above either side of temp controls. Next slide slightly to the right to disengage the two large-headed screws (or remove them completely... it seemed easier to just leave them in place.) Dropped front end of control assembly down.

3) Opened plastic box surrounding ADA and pried open locking tab holding it to wiring. Connected new board and set ADA assembly back in place.

4) Put everything back together.

Plugged fridge in and all was well. Exposed the coils again a few days later and they were not frosted up at all.

Total time to replace the ADA was about 20 minutes. Total time for everything including defrosting coils, testing, replacing parts, etc. was an hour max.

The threads on the yoke shaft stripped.

  • Customer: Steven from Crossville, TN
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Wrench set
  • 10 of 20 people found this instruction helpful
I had to cut off the old yoke since the threads had stripped and it would not come off. Once I did that all I had to do was to remove 4 screws on the auger motor and replace it with the new auger motor. Then I put the yoke on the new auger motor shaft and then put the unit back in the freezer. Work time was less than 15 minutes with no problems.

fridge ouit cooling

  • Customer: danny from adelanto, CA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 8 of 14 people found this instruction helpful
where the wires crossed at the start relay, 20 years of vibration allowed them to short out and burn out the start relay ..since i have 2 identical fridges i switched the run capacitor to determine it was'nt bad too...ordered a start relay wednesday nite and got it friday morning...cold fridge by noon...good service and the part was exactly the same as the original....

Icemaker would not fill with water.

  • Customer: Linford from Cedarville, NJ
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 6 of 9 people found this instruction helpful
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.

Seal wouldn't seal on the freezer's right bottom. When you shut the refrigerator door with any force the freezer door would come open a tad.

  • Customer: Shannon from Chapin, SC
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 5 of 6 people found this instruction helpful
Removed all 50 screws and replaced the seal. The door still comes open a tad but now it seals all the way. This was my first and last Maytag.

My old icemaker lost some of the nonstick surface and the ice didn't want to come out

  • Customer: Thomas from Ruth, MI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 5 of 6 people found this instruction helpful
I unhooked the wire harness from the ref. and took out three screws and pulled the old unit out. I than changed a few parts from the old icemaker to the new and reattached the new ice maker to the ref. and plugged the wire back in. everything is working fine. No problems. Also I was very happy with the ordering process. Thank you!!

replacing thermostat did not help

  • Customer: John from Rocky River, OH
  • Difficulty: Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Pliers, Screw drivers, Socket set
  • 6 of 9 people found this instruction helpful
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed

The in-door water dispenser was dripping.

  • Customer: Denny from Westminster, CO
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench (Adjustable)
  • 5 of 6 people found this instruction helpful
I reasoned that the water-value was caked with hard water deposits, or perhaps just worn out. I traced the plastic water line to the back of unit, then found the double water valve. I was not "sure" that this was the problem, but I order the part any way and it fixed it!! The removal /installation was pretty easy. First turn off the water supply to the unit. Then loosen and remove the incoming copper pipe from the unit. Remove just two 1/4 in. hex head screws and carefully pull the unit out a bit. Then remove the electrical connectors and the plastic tubing connectors. Just do the reverse to install it. I am very happy with the item ordered from PartsSelect. Perfect. And shipping time was fast too. Thanks guys.

broken light switch

  • Customer: Richard from West Warwick, RI
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 6 of 9 people found this instruction helpful
followed the instructions provided and that's it!
All Instructions for the JCD2289AES
76-90 of 784