Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always

  • Customer: JAMES from Middleboro MA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 5 of 7 people found this instruction helpful
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels

Freezer too warm; noticed sides of refrigertor were warm

  • Customer: W from Nellysford VA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
  • 3 of 4 people found this instruction helpful
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.

Refrigerator quit cooling and the freezer wasn't freezing anything

  • Customer: Tonya from Grand Prairie TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set
  • 3 of 4 people found this instruction helpful
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.

The threads on the yoke shaft stripped.

  • Customer: Steven from Crossville TN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Wrench set
  • 6 of 14 people found this instruction helpful
I had to cut off the old yoke since the threads had stripped and it would not come off. Once I did that all I had to do was to remove 4 screws on the auger motor and replace it with the new auger motor. Then I put the yoke on the new auger motor shaft and then put the unit back in the freezer. Work time was less than 15 minutes with no problems.

condenser fan stopped working

  • Customer: Steven from Brigham City UT
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 3 of 5 people found this instruction helpful
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.

Condenser fan making noise

  • Customer: Richard from North Easton MA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Wrench set
  • 2 of 3 people found this instruction helpful
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.

Condenser Fan Motor seized up

  • Customer: Peter from Herndon VA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 2 of 3 people found this instruction helpful
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!

Condenser Fan Failure

  • Customer: Al from Tonka Bay MN
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 2 of 3 people found this instruction helpful
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great!

Bad fan motor

  • Customer: Mark from Farmington Hills MI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 2 of 3 people found this instruction helpful
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.

There was no light on in refrig area

  • Customer: Lori from Chuluota FL
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 3 of 6 people found this instruction helpful
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.

Replace broken ice cube trays

  • Customer: C MARTIN from TAMPA FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 2 of 3 people found this instruction helpful
No repair needed. I had only to wash the new ones and use them.

light inside fridge was flickering and clicking

  • Customer: bill from escondido CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 3 of 6 people found this instruction helpful
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok

Door light switch disintegrated

  • Customer: Thomas from Roseville CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 1 of 1 people found this instruction helpful
Very simple fix, remove 3 screws, two connectors to the old switch

missing clips

  • Customer: Gaylon from Auburndale FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 2 of 4 people found this instruction helpful
I had to find a couple screws that would match the clips and kickplate. I screwed on the clips. The kickplate snapped on perfectly.

The switch broke...absolutely fell apart.

  • Customer: Duncan from Metairie LA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 1 of 1 people found this instruction helpful
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service!
Duncan Quaid
All Instructions for the ICNF17E8