condenser fan stopped working

  • Customer: Steven from Brigham City UT
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 7 of 9 people found this instruction helpful
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.

light inside fridge was flickering and clicking

  • Customer: bill from escondido CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 7 of 10 people found this instruction helpful
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok

Freezer too warm; noticed sides of refrigertor were warm

  • Customer: W from Nellysford VA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
  • 6 of 7 people found this instruction helpful
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.

The Shaft of the Auger Drive Motor Became Stripped

  • Customer: Anthony from Amenia ND
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 7 of 11 people found this instruction helpful
I removed the one nut screw holding the Ice bucket shelf then removed the Ice Auger Container. Then I lifed the Part containing the Drive Motor. I removed the electrical connection which just plugs into the fridge. Once the Drive motor and container was out of the fridge I removed 4 screws and the Drive motor was out. I disconnected 3 electrical connectors and connected them to the new drive motor. Then replaced the motor and connected the 4 screws. I then installed the yolk on the drive shaft and then put the drive motor container back in the fridge and reconnected the electrical. Installed the nut screw and I was done.

The threads on the yoke shaft stripped.

  • Customer: Steven from Crossville TN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Wrench set
  • 10 of 20 people found this instruction helpful
I had to cut off the old yoke since the threads had stripped and it would not come off. Once I did that all I had to do was to remove 4 screws on the auger motor and replace it with the new auger motor. Then I put the yoke on the new auger motor shaft and then put the unit back in the freezer. Work time was less than 15 minutes with no problems.

Refrigerator quit cooling and the freezer wasn't freezing anything

  • Customer: Tonya from Grand Prairie TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set
  • 4 of 5 people found this instruction helpful
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.

All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator

  • Customer: Antonio from San Antonio TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 5 of 8 people found this instruction helpful
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.

There was no light on in refrig area

  • Customer: Lori from Chuluota FL
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 5 of 9 people found this instruction helpful
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.

The switch broke...absolutely fell apart.

  • Customer: Duncan from Metairie LA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 3 of 3 people found this instruction helpful
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service!
Duncan Quaid

Condenser Fan Motor seized up

  • Customer: Peter from Herndon VA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 3 of 4 people found this instruction helpful
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!

Raplaced switch

  • Customer: Winston A from Brooklyn NY
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers
  • 3 of 4 people found this instruction helpful
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!

Light didnt go on

  • Customer: dorotea from staten island NY
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 3 of 5 people found this instruction helpful
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!

Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...

  • Customer: David from Hemet CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 2 of 3 people found this instruction helpful
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!

lights wouldn't come on/work in refrigerator

  • Customer: Jane from Albuquerque NM
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers, Socket set
  • 2 of 3 people found this instruction helpful
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!

Replace broken ice cube trays

  • Customer: C MARTIN from TAMPA FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 2 of 3 people found this instruction helpful
No repair needed. I had only to wash the new ones and use them.