No ice

  • Customer: James from Solon OH
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 72 of 89 people found this instruction helpful
Removed the plate on the back of the refrigerator, removed the bolt holding the water valve in place (didn't know you could cut the water line to get it off), Plugged in the new water valve and water lines, 15 minutes, very easy to do.
Removing the ice maker was easy, 2 bolts and a plug. Loosen 2 bolts, lift the ice maker off, unplug it. Put the water chute and ice guard on the new one, put it back on the bolts, spend 1/2 hr getting the plug back in (couldn't see past my own hand), Tighten the bolts and you're done.
Really not difficult, except that the plug was angled, and I had to go by feel.

Evaporator motor sounded like wind in the trees howling

  • Customer: DOUG from MARYSVILLE OH
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 61 of 65 people found this instruction helpful
I had to remove all of the shelves.....part of the ice maker.....the rear cover over the freezer coils.....There were two wires that came from the back of the freezer that were also incorporated with the fan motor plug from the factory....This caused me to cut all of the wires from the new motor and soider them to the existing plug and shrink wrap the connections. If GE would have supplied two new ends I could have cut only those wires added the ends and inserted them into the new motor plug thus eliminating an extra hour and a soildering iron,,,,In my case not a big deal however not a project for those who have trouble with repairs using these type of tools.

Repeatedly stick in defrost, raising temps in fridge and freezer for hours at a time, some times for days. Repair tech was called out twice to look into this problem, but the temps returned to normal both times before he arrived, therefore, he never could diagnose the problem with a certainity as wh

  • Customer: Jerry from Otisco IN
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 57 of 61 people found this instruction helpful
The main board is easy to get to behind the access plate. You will find seven different wire harness plugs, six which are white, that are impossible to remove without breaking the retaining clips which hold them in place....but that's OK.....you are throwing away the old board anyway, so nothing lost. The plugs will snap back into each of their respective terminal locations without a problem. Be sure to treat the four white, plastic pins that hold the board in place delicately....you will not want to mess those little dudes up!

Flapper Door Stuck Open Allowing Ice Tube To Frost Shut

  • Customer: Joe from Maryville TN
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 56 of 60 people found this instruction helpful
I read in a previous post how to do the job from outside fridge which saved me lots of time. No need to remove inner door lining. Here is my procedure:
1.Turned off power. 2.Snapped off outside trim ring. 3.Located three small holes inside lip just above ice tube. The center hole was not used. 4.Pushed rather firmly up through two remaining holes with small Allen wrench to release front control panel. 5.Removed (3) wire connectors from printed circuit board. Firmly pull/pry them straight out as lifting on retaining clip will break it off. I broke one & had to elect. tape it back in place later although I doubt it would have ever come off. 6.Release secondary panel by removing (4) screws. The problem was obvious as the solenoid had broken the crank arm off the flapper rod & trapped it open 7.Replaced solenoid, crank arm with flapper attached, spring & micro switch. Switch was okay but I changed anyway. 8.Cleaned all areas with 1/10 bleach water to sanitize. 9.Re-installed evrything in reverse order & all is okay. Thanks to someone for telling about those two small holes. Made job easy versus a very hard one.

Ice dispenser quit working and kept making a clicking sound

  • Customer: Ken from Gibson City IL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Pliers
  • 53 of 59 people found this instruction helpful
All you have to do is replace the circuit board which is really easy. Still kinda mad because the fridge is less than 2 years old. If you hear the clicking noise its coming from the circuit board.

My refrigerator began to overheat and the everything was thawing!!

  • Customer: Jeffrey from Tampa FL
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 54 of 65 people found this instruction helpful
My refrigerator began to overheat and the everything was thawing!! The condenser fan motor had seized and I thought this is something even I can replace.

I did a Google search on the refrigerator model number. The link to your site looked promising and I clicked on it. I was taken to your web page for my refrigerator and I clicked on the schematic for the condenser assembly.

The schematic had the parts I needed labeled clearly so this layman could be sure to get the right ones.

I ordered the parts at 12:45PM Monday and selected overnight shipping. The parts arrived at 8:35AM Tuesday (Thank you FedEx). I installed the parts and my refrigerator is up and running again.

To get to the condenser fan motor I took off the back panel on the fridge that covers the condenser, fan and coil. The fan/motor assembly is attached to a bracket I removed with two screws. Pulled the bracket assembly out of the back of the fridge, removed the fan blade and then the motor, and put the new motor on the bracket and stuck the new fan blade on the motor spindle. The trickiest part was getting the complete assembly back in. Just went slowly and took my time. Reconnected the wires, no problems. I took pictures of everything that I disassembled BEFORE I disassembled it in case I wasn't sure how something went back in but this job was so simple I didn't need the pictures.

I’m not sure how I could improve on this except maybe you could ship a refrigerator technician, too, to do the install.

Thank you PartSelect everything worked out better than I could have hoped and I saved $220.00 compared to what a repair service was quoting.

Refrigerator stopped freezing and cooling frige

  • Customer: DAVID R. from BATH NY
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 48 of 53 people found this instruction helpful
Well, I first had a local service guy look at the frige. only to find out his opinion was to replace the entire unit, because the Mother board cost more than the unit was worth. Me not accepting that answer, decided to look on line for a part and availability as well as price. Surprise, Part Select had what I wanted. Now, on the back of the unit in the upper left hand corner is the access door for the mother board.Find it, but before proceeding disconnect the power supply from the wall receptacle. Remove the surrounding screws on the access door with a nut driver and the correct size METRIC socket. Disconnect the wiring connectors on both sides of the board. Now there are 4 plastic type (mine were white) retaining studs holding the board in place. BE CAREFUL not to break these as you gently pull the board off studs. Replace board with new one, and restore wire connectors in their perspective places. Each connector has a different amount of pins inside so connecting them is easy. I know nothing about refrigeration, and this was a piece of cake. Less than 15 min. Unit cools like never before!!!

Our refrigerator stops delivering ice both crushed and cube. The ice bin was full. I first thought the delivery motor was bad and then the water dispenser in the door stopped delivery. Decided at that point it was either the door panel swith board, cable or the main circuit board on the back of t

  • Customer: david from colleyville TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 47 of 53 people found this instruction helpful
After further diagnosis decided the main circuit board was the likely culprit. Ordered a new one from PartSelect. It came in 2 days and took less than 30 minutes to install. Unplugged the refrig. Removed the old board cover with a nut driver. Removed the wiring cables (note their location on the board) and also there were a couple of cable plugs on my refrig that were not not hooked to anything on the board. Snapped the old board out and the new board in. Reinstalled the cables and then the board cover. Plugged the refrig in and back in business. PartSelect is a great website! The speed of delivery and available information just saved me $500 to $600 from a appliance repair shop.

refrigerator was getting too cold

  • Customer: Larry from Menomonie WI
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required:
  • 50 of 63 people found this instruction helpful
I removed the old temperature sensor by cutting the wires. I attached the wires of the new sensor with wire nuts and mounted it in the same bracket.

refrigerator/freezer defrosting completely for no reason

  • Customer: John from Yucca Valley CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 44 of 46 people found this instruction helpful
Unplugged refrigerator and used a screwdriver to remove access panel on rear of refrigerator to expose "mother board". Unplugged connectors (6 total) and using needle nose pliers released two retainers to remove mother board. Installed new mother board snapping it onto the two retainers and plugged the connectors onto the new mother board. Plugged refrigerator into outlet, refrigerator came back on, automatically reset it's temperature settings and has been working fine since. Total time, less than 15 minutes. Money saved, hundreds of dollars!

freezer defrost and then after some time would work.

  • Customer: anthony from burke VA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers
  • 43 of 45 people found this instruction helpful
one repair man said I needed freon. sears repair man said my evaporators leaked. and should buy a new fridge. I installed the parts for less than $30.
dried the freezer compartment removed back panel and asst parts. removed screws from evaporator assy and replaced def therm. soldered leads/wing nuts. removed cover from sensor temp and again connected leads. working fine.

Ice jamming up in the ice maker unit because auger was broken

  • Customer: Elaine from Healdsburg CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 42 of 45 people found this instruction helpful
Remove Ice maker bin from the refrigerator and empty. Unscrew the three Phillips head screws that secure the front plate to the bin and gently lift and pull the tab that secures the interior portion of the plate until it clears the bin. Once you remove the front plate, it will expose two side tabs on the front of the bin which must be depressed so that the plastic insert that hold the auger in place can be removed. Isolate the auger with the from the unit by rotating the parts off the shaft. The ice crushing blades are attached to the auger and can easily be removed by twisting the plastic nut off with pliers. The cutting blades will now slip off the end (make sure you study the orientation of the blades as each piece will come off separately and make the job unpleasant when you go to put it back together). Now that the auger is out, just reverse the process and you have a "new" ice dispenser. Works like a charm. The diagram furnished by PartSelect was very helpful and accurate if you get a bit lost, especially when putting the crushing blades back together.

Clicking noice from the motherboard

  • Customer: John from Greer SC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 39 of 40 people found this instruction helpful
After advise from the expert, he was adamant the motherboard was the (via symptoms)problem. After receiving the replacement board (via FEDEX), I followed the easy to understand instructions. I did number the electrical plugs and mapped the connections on paper. The key to the rapid fix was to carefully read all of the instructions to verify which (if any) wires needed elimination, which in my case was none. I will definitely use this service in the future as the expense was affordable and after research, I estimate a savings between 55% to 60%.

ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.

  • Customer: Gerald from Benicia CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 38 of 40 people found this instruction helpful
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.

Sticking Light Switch

  • Customer: Jonathan from Lilburn GA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 39 of 43 people found this instruction helpful
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the catch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.