Models > GC2225GEK3 > Instructions

GC2225GEK3 Maytag Refrigerator - Instructions

All Instructions for the GC2225GEK3
1 - 15 of 315
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
light on to order water filter
Pressed in the end of the filter cover, lowered it down part way. Twisted the old filter 1/4 turn and removed it. Set in the sink to drain. Inserted new filter and twisted it to lock. closed cover. Done. Total time @ 1 Minute.
Parts Used:
Refrigerator Water Filter
  • Douglas from Byron, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
896 of 1007 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer is cold, Refridgerator is not as cold as it should be
Having seen this problem before in other equipment so I had an idea where to look. Problem: the automatic defrost function was not operating. Looking through openings in the back panel of the freezer compartment, you could see the evaporator coils and fins were a solid chuck of ice. There are three logical components to check. Heater element, thermostat (located just above the evaporator) and a relay on the control board (located in the fridge control panel). Checked the heater with an ohm meter -- OK. The thermostat closes the circuit at around 20 degrees and opens at around 32 degrees. Pulled out the thermostat, wiring, fan unit. Everything unplugs, unscrews, and unclips, don't cut wires. Put the whole assembly in a friends freezer for an hour or so to see if the thermostat closes -- OK. Problem had to be with the control board. Replaced control board, reprogrammed it per included instruction. Everything is working again.
Parts Used:
Electronic Control Board
  • Russell from Hardinsburg, KY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
352 of 427 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defroster mode was not working causing freezer to ice up and refrigerator to be warm. Also fan was running continuely
The hard part for me was figuring out which part was causing the problem. I read what others had done and followed their test methods. I checked the defroster heater for continuity and the defroster thermostat to make sure it was closing. the defroster termostat has to be cold to check it. You will need to check it while it is in ice or take it out and put it in another freezer for 30 mins and then check it for continuity. Those items checked out ok so it had to be the control board. The control board is a 5 min job to replace but making sure that is your problem is the hard part. I think the control board was bad due to a power surge we had when the power went out and came back on. It might be a good idea to put a surge protector on your home to protect your fridge and all your other electronic stuff. Our refrigerator is now working like new again. Thank you for all your help, Jim
Parts Used:
Electronic Control Board
  • James from Welches, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
180 of 211 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Removing the existing filter by rotating as directed and then dislodging from 'docking' station proved difficult. Turns out, the old filter is under a bit of vacuum pressure and getting the unit to separate or release was a challenge.
I removed the drop-down outer housing by gently prying the sides of the two pivot pins at the rear. This gave me move 'room' to grip and slightly rotate then pull the old filter forward and away from the tight suction connection. I was concerned that I would be too forceful for the plastic assemblies and would break something; deliberate motions and a steady thought process on the problem helped disengage the darned old filter!
Parts Used:
Refrigerator Water Filter
  • Jake from Novato, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
212 of 323 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Top unit was not getting cold
First thing to do is take two screws off where the door closes.I removed the light sheild off by pushing it to back of refrig.The most hardest part is removing the complete panel,I took a small flat blade scraper to ply down to get small access than you need to put alot of pressure to start getting the panel to start coming off there are alot of pegs to free,the back panel has two hinges that slide towards the front.Once the panel drops remove the connectors and take entire unit out,very easy to replace the control board at this point.Installation is easy slide the two hinges on back in place and put pressure on unit to snap entire unit in place.Program unit with paperwork that came with part very easy to do.Frig is working great now.Just a note the paperwork on refrig is located in the front right corner the mf hids it ,this information will allow you to check all problems with refrig using the key pads for freezer/refrig.Good luck.
Parts Used:
Electronic Control Board
  • Gregory from Lexington, SC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
144 of 163 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Needed to change water filter in refrigerator
The switch-out of the water filter was simple with good instructions on the box.
The part was delivered very, very quickly!
Parts Used:
Refrigerator Water Filter
  • Marilyn from Lilburn, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
160 of 248 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water filter needed replacing
I unscrewed the old one and replaced it with the new one. The real benefit was I got the exact part I needed w/o a 30 minute drive and sales people that ignored me. I had gone to the local store the day before and come home with the wrong part because i could not get assistance and the part # I had did not match what was labled on the package. I used the same part # on the website and got exactly what was needed, less that 48 hrs after I ordered it. thanks for the prompt service. we will be a repeat customer
Parts Used:
Refrigerator Water Filter
  • Kathryn from Cedar Springs, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
111 of 123 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
Parts Used:
Water Fill Cup and Bearing
  • David from Chester, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
107 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would not close
After emptying the refrig. door, I unscrewed the plate on the top of the refrigerator that covered the door bolts. Then off with the three bolts. I removed the door by lifting it up a few inches. The two parts of the door cam were easily removed and replaced with the new part. BEFORE REPLACING the door spread vasoline on both cam parts.
(Not after as I did. The second time you do any of these repairs go SO much better :o)
After putting the door back on, adjust the tension of the screws holding the door in place if needed to align the door on the cams so that it shuts completely. Failure to do this will require taking the top off the door again. (see comment above on "... second time...")
If all is properly aligned, the door should swing completely shut.
Even with the mistakes that required removing the door to lubricate the cams, and removing it AGAIN to readjust the screws on the top to properly align the door on the cams, this was a twenty minute job. My wife and I were still speaking to one another at the end of it- a sure sign of an easy repair.
Parts Used:
Door Closure Cam Kit
  • Russ from Asheville, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
79 of 84 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice in ice trey
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace holding pins and start the process of putting back together the opposite way you took it apart.
Parts Used:
Cycling thermostat
  • Wayne from Leesburg, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
78 of 100 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor did not shut off evaporator freeze up
replaced control board
Parts Used:
Electronic Control Board
  • Dave from Southampton, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
90 of 156 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
easy and quick
unscrewed to removed old and screwed in new
Parts Used:
Refrigerator Water Filter
  • alvin from irmo, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
87 of 163 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not turn allowing the ice to come out the dispenser. The ice bucket was also cracked from kids (ok and parents) getting frustrated and shaking the ice bucket!
Piece of cake!

Removed the old ice bucket which was cracked and ice would not dispense. The Helix Cap also looked worn which is why I ordered both parts. (Probably if not for the shaking of the ice bucket the Helix cap would have been the only part required. We ended up cracking the ice bucket) Removed the four hex screws from the auger system on the old ice bucket with a socket wrench. Removed the old Helix end cap from the auger system and replaced with the new. Literally just slips on the auger. Reinstalled auger system back onto the new ice bucket. Total time not even five minutes.

Working great! Probably saved $ 75.00 - $ 100.00 on a service call. Half of a wrench on skill level needed (One=Low skill level/ Five=High skill level)

Great response & delivery from Parts Select!
Definitely recommend highly.

Todd
Lancaster-PA
Parts Used:
Ice Bucket Ice Maker Helix End Cap - white
  • Todd from Lancaster, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
50 of 56 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
while closing the door, the light switch fouled, resulting in the switch breaking
I used a flat screwdriver and released the lock tab on the bottom of the light switch, and pried the switch out, being careful to not damage the plastic around the mounting place of the switch, unplugged wiring from old switch, plugged in the new one and pushed the new switch into place. Job finished light switch now working.
Parts Used:
Door Switch
  • Kevin from Beckley, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
59 of 88 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker did not make ice
The ice maker was not getting water. I hotwired the water valve by switching the connectors for the water dispenser and ice maker water valves and water flowed into the icemaker when the water dispenser lever was pushed. I wronly assumed the water valve was good. I removed the icemaker and determined that the gear motor was not getting power in the position the icemaker had stopped.In this position, the thermostat determines when the motor gets power so I replaced the thermostat. The icemaker still would not get water! As it turns out, the water solenoid was sticking due to a deteriorated rubber washer which let the solenoid plunger get too far out of the magnetic field. I replaced the water solenoid assy and all is well. Don't get fooled by hotwiring the valve. If it isn't getting water, the solenoid probably is the culprit.
Parts Used:
Cycling thermostat
  • DAVID from TINLEY PARK, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
47 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GC2225GEK3