I have a fridge in my garage. I have found that a glass of ice water or a cold drink outside is very important to me. When I discovered melting ice dripping onto the garage floor I was very upset. I spun the fridge and found that the compressor and fan weren't starting. I got out my multi-meter and discovered that power was not making it to these components. I did some research and found the wiring diagram online. There really isn't too much going on with a fridge and the most likely candidate seemed to be the run capacitor. I ordered the part, replaced it in a few minutes and the fridge began working again.
unplugged refrigerator. removed light bulb from old socket. unsnapped old light socket and pulled it out just enough to diconnect the electrical plug that plugs into the socket . discarded the old socket and plugged in new socket. snapped in new socket into refrigerator. i watched how to do this simple procedure on you tube and decided to do it myself. easy easy easy
I checked the compressor and it was running. Next I removed the doors amd screws that held the divider strip. Next removed the bottom of the freezer to expose the evaporator fan. Removed the fan and checked it out with volt ohm meter. Discovered the fan motor was out. Ordered new one on line and received thenext delivery day. Insatlled in reverse of disassembly. When I plugged it in everything worked fine. Thanks for the quick delivery. You provided fine service. Sincerely, Joe Sutphen
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.
Getting on the internet was so easy. This was really very simple. Thank you for making what I thought would be a big ordeal into something very simple.
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Freezer not getting cold enough to freeze ice cream
I took the advice off of your website about the only thing that will fix the problem is change the run capacitor. I felt assured that I would have a working refrigerator freezer after making this change. I was pretty disheartened when it didn`t solve anything. I was not going to take the new part back out after the small challenge of putting it in. The next day I found out how to test the old capacitor and it was still good. I will just have to eat the $49. I did learn not to take advice from a website even if it seems like a sure thing
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugged it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor. Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
Pulled the door off easily and noticed that the spacer on the Center hinge was ground down to nothing and that a small screw in the bottom plate of the door was half way out. This screw would catch on the cabinet Center hinge bracket and stopped the door from closing. Problem was solved by tightening the screw and putting in a new "spacer" that kept the small screws from contacting the Center hinge bracket. The freezer door now closes like new.
freezer compartment worked fine but very little cooling going to refrigerator section.
Freezer worked great but no cooling to refrigerator section. Replaced with part ordered. Phillips head screw driver is all that is needed. Very easy to replace, it's plug and play. New part powered up neither the freezer nor the refrigerator. Went back to old part and atleast freezer still works. New part was no good from factory. The replacement part# matched the original. I attempted to contact PartsSelect but there was no response back.