Models > FFU20FC6AW4 > Instructions

FFU20FC6AW4 Frigidaire Freezer - Instructions

All installation instructions for FFU20FC6AW4 parts

These instructions have been submitted by other PartSelect customers and can help guide you through the freezer repair with useful information like difficulty of repair, length of repair, tools needed, and more.

All Instructions for the FFU20FC6AW4
1-15 of 64
Search Instructions
Keep searches simple, eg. "belt" or "pump". Need help?

Faulty Controller and Possibly Capacitor

  • Customer: eric from inglewood TN
  • Difficulty: A Bit Difficult
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 21 of 24 people found this instruction helpful
After building a test box and determining the Controller was bad simply ordered parts and installed. Installation was a little difficult due to locking spades on electrical connections.

Unplug all power from freezer. Remove Bail wire from controller capacitor unit and remove from compressor by pulling STRAIGHT from compressor body to avoid bending contacts.

Use a very small instrumentation screwdriver to release locking spade on yellow and white wires. To unlock slide screwdriver in slot along wire entry to controller body while gently pulling on wire. Note position of wires and replace on new unit in same position/order. Plug new run capacitor into new controller being careful to orient capacitor to proper position (hole matches guide on controller unit). Plug newly installed controller and capacitor into condensor and replace bail wire.

Make sure timer is not in defrost mode - manually advance timer if necessary to ensure timer is in run mode. Turn temperature control to coldest setting. Plug in and hopefully enjoy the humming noise of your newly repaired and operational compressor and freezer.

Rails for basket drawer were broken.

  • Customer: John from Vancouver WA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 18 of 20 people found this instruction helpful
The repair was as easy as removing three phillip head screws for each slide rail and removing and replacing the broken slide rail. However, over the years, the walls of the freezer had bowed making the drawer a bit short to ride on the new rails -- causing the drawer to fall off the slide rails since the span between each rail was now wider than the basket. To remedy this problem. I used washers and placed them on the back side of each rail where the screws are located . This was the perfect solution compensating for the extra width resulting from the slightly bowed walls in the freezer. This solution allowed the basket to fit on each slide rail without falling off .

Temp alarm sounding and food on top shelves partially thawed

  • Customer: Wayne from Forest Hill MD
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 12 of 12 people found this instruction helpful
After silencing the alarm, it seemed to be running as normal without any unusual noises, but food was starting to thaw from the top shelf on down and condensation was dripping from the roof. We were able to place most of the food in 2 large ice chests and then the rest in the freezer compartments of 2 fridges we have in the house. I then turned down the temp dial to the coldest setting and let it run for an hour or so; no change.

After researching on the internet, it sounded like our symptoms could be pointing to a defrost timer issue. I pulled the freezer away from the wall, located the timer and used a large screwdriver to slowly advance it. While doing this, at one point I could hear the compressor kick in. I pushed the quick freeze button and let it run for a while. When I checked it in a few hours, the alarm light had gone out and water that I had placed inside was frozen. We took a chance and put the food we placed in the ice chests back in the freezer. Everything was fine several hours later.

I ordered a new defrost timer, it arrived in a couple of days, and replaced the old one with it in a matter of minutes by disconnecting the wire harness from the old timer, removing the 2 screws holding it onto the bracket, screwing the new timer to the bracket, reconnecting the wires harness, and done. It's been a week or so and no problems.

freezer compressor ran continuously and freezer getting colder and colder.

  • Customer: john from hurst TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 12 of 14 people found this instruction helpful
Repair was quick and easy. I removed the frozen food in the bottom so the back panel could be removed. The temperature comtrol is attached to the back of that panel. It has a metal wire with a capillary tube on the end to sense the temperature. I just installed it exactly like the old one came out. Be sure and don't get the wires mixed up. Sometimes it helps to make notes. This was also a good time to clean the bottom out and make sure the drain hole was clear.

It took two days for the temperature to stabilize. I was anxious for a couple days that there was something else wrong. However, it smoothed out and the temperature control (thermostat) is now working properly.

Freezer was getting all iced up...

  • Customer: Cheryld from Florence SC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 11 of 14 people found this instruction helpful
Watched the defrost timer to see that it wasnt moving, looked the part number up on your site and it even had a picture of it so I knew I was getting what I needed, ordered it when it came I took out the screws holding it in place unplugged old one and plugged in the new one, freezer works like new... :))

freezer would run then thaw then freeze. tap on the control knob, it would start running again

  • Customer: WILLIAM from URBANA OH
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 11 of 14 people found this instruction helpful
Easy fix. I unplugged the freezer, unload items in freezer. took out shelves and baskets, Pulled off the control knob then removed all screws. removed inside panel, replaced part exactly as I took out old part. Put the panel back on, put everything back in place. Plugged freezer back in and turned the knob to 3. Let freezer run for a day to see if I ordered the correct part. Problem is fixed. Thank you, PartSelect for making it so easy to find, order the correct part and for all the customers input to make the repair easy.

freezer was stuck in defrost mode - - stayed at 30 degrees

  • Customer: don from stony point NY
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 12 of 18 people found this instruction helpful
slid freezer away from wall - - bottom left hand corner was the frost timer - - removed two philip head screws - - unpluged timer and installed new timer - - turned timer past first click to a little past second click (freeze cycle) - - slid freezer back FINISHED - - YOU GUYS ARE THE BEST WITH YOUR WEB PAGE AND HELP!!!!! Next day freezer was at 0

replacement freezer keys

  • Customer: CHARLOTTE from SEDALIA MO
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required:
  • 9 of 11 people found this instruction helpful
I accidently threw away both freezer keys to our upright Gibson and G.E. Freezers!!!! I had no luck finding replacements locally, so I got on the internet and came across PartSelect.com. I called them on the telephone; and after giving the model numbers of my freezers, the keys were on their way!! I received the keys very quickly and both worked perfectly. I would highly recommend Partselect.com. Charlotte M. Bishop

Freezer was not cycling and started freezing up around the compressor but was not able to freeze inside the box.

  • Customer: James from Biloxi MS
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 10 of 14 people found this instruction helpful
I knew that the problem had to do with the timer so I went online and looked at the schematic diagrams on Partselect and identified the part that should handle the problem. I ordered it and it arrived fairly quickly. It took a Phillips screw driver and about fifteen minutes to remove the old part and replace it with the new one. Very easy repair. It is working as it should now.

Freezer would over temp and decrease cooling efficiency

  • Customer: Steven from Alamogordo NM
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 7 of 8 people found this instruction helpful
One day my freezer's overtemp light/warning came on. I knew the compressor was working properly (as it was still running) and that there were no leaks.

I was able to research about how this freezer worked and learned of this mechanical timer on the back of the freezer. It turns on/off the defrost mode of the freezer.

I manually turned the knob on the back to see if I could get the freezer to defrost. Turns out the timer was no longer working and when I manually ran the defrost, the freezer started to freeze again.

I just replaced this part and my freezer is working like norma.. Simple as all it takes is a few screws and you are done.

frezer not staying cold enough to freze newly added product

  • Customer: Robert H. from Grand Blanc MI
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 8 of 12 people found this instruction helpful
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you

Fan Motor not working

  • Customer: Richard from Albuquerque NM
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 7 of 11 people found this instruction helpful
Fist I removed the tow screws that hole the fan bracket - then remove the 2 screws that hole the fan-disconnect the wires and replace new unit.

Defrost function in freezer was not working, while the refrigerating side was warm

  • Customer: Sophia from San Antonio TX
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 5 of 6 people found this instruction helpful
1. Turned off and unplugged the refrigerator.
2. Removed the lower back panel inside the freezer with a screwdriver.
3. Unplugged the thermostat. (No tool is needed)
4. Ordered a new thermostat from PartSelect and it arrived in 2 business days.
5. Plugged in the new thermostat..
6. Put the lower back panel inside the freezer with screwdriver.
7. Plugged in the Refrigerator and turned the power back on.
8. It is working again!!!

Freezer compressor quit running causing freezer to defrost and ruin all contents.

  • Customer: Kenneth from Safford AZ
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 6 of 9 people found this instruction helpful
Very simple repair. Removed the bail that holds the compressor controller and run capacitor from the compressor, removed the controller & capacitor, inserted a very small screwdriver into the controller to compress the barbs that hold the electrical wires to the controller. Plugged in the wires to the new controller in the same position as the original, plugged in the capacitor and then plugged the entire unit back onto the compressor, replaced the wire bail, plugged in the freezer and repair was complete.

The freezer door wouldn't stay shut due to two irresponsible children.

  • Customer: Paul from Cape Coral FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 5 of 8 people found this instruction helpful
We ordered the part, which was a key, tied it on the freezer door handle, locked the door and voila, the problem was fixed. (We still have the children. :-)
All Instructions for the FFU20FC6AW4
1-15 of 64