Water Inlet Valve Damaged
The Speed Queen people were nice enough to provide a swing out door on the back of the machine to access the mixing valve. I had to pry it open because they did not supply enough slack in the hose that attaches to the mixing valve. The hose clamp securing the outlet hose to the valve was difficult to remove as the screw was positioned by someone that assembled the machine with no thought given to if it would ever to be taken apart.

Be sure to unplug the machine before attempting this repair. I unplugged the dryer instead and was greeted with a shower of sparks as I removed the valve. Luckily there was no damage to me or the machine. I needed some lubricant to slide the hose onto the new valve. There was some Linatone oil for my dog's coat handy. It did the trick I buttoned the machine back up and it works as good as the day I bought it.

It might be wise to replace the gaskets between the water hoses and the inlet valve. They are just standard garden hose gaskets. Replacing the strainers on the faucet side might be a good idea also. I took a video of the Speed Queen in action and will post it to You Tube. "They Don't Make 'em Like This Anymore"
Parts Used:
Water Inlet Valve
  • Ronald from Arcadia, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad tube seals and bearings
Disassembled washer as per directions with seal kit. Removed inner tub. Cut both tub shaft bearing in half; punched out from outter tub. Installed new bearings using .5 inch threaded rod, washer and bolts. Installed new seal on inner tub shaft. Installed inner tube. Re-assembled washer.
Parts Used:
Single Washer Inlet Strainer
  • DAVID from SANDY HOOK, CT
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Socket set, Wrench set
1 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaked into the drum while turned off cycle.
As another person commented, there is a small 'door' on the rear where the water inlet is located. Don't know if this was meant for easy access to change this part or not but I didn't use it. I found it much easier to just remove the front panel (2 lower corner screws), loosen the top (2 corner screws) and tilt it up and out of the way. From there it was easy to disconnect the hoses and four electrical plugs (easy to remember the order). The unit is held in place by one screw which is located between the water inlets.
Parts Used:
Water Inlet Valve
  • Brian from Evansville, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!