Models > EMO3000HBB03 > Instructions

EMO3000HBB03 General Electric Microwave - Instructions

All Instructions for the EMO3000HBB03
31 - 45 of 459
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
broken handle and cracked outer door frame that handle attaches to
I removed the inner flexible plastic door frame (light grey) which allowed me to get to the screws that held the handle. I then carefully pryed the broken outer door frame off by pulling each side down and out. Next I removed the glass door front from the broken outer frame and smapped it into the new outer frame. I attaced the new handle with one screw to the top and one to the bottwm on the new outer frame. Finally I snapped the entire outer frame back on the microwave and added another screw to the top and bottom of the handle. Hint: These plastic parts are extremely fragile so use great care when snapping the parts back onto the microwave.
Parts Used:
Door Handle - Black Outer Door Frame
  • susan from south hadley, MA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
20 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
turntable wouldnt turn,and light sockets were cracked and brittle.
turntable coupler was an easy switch from inside the cooking area(pull out and push in the new part).The light sockets were accessed by removing five screws under the microwave,lowering the panel and replacing the light sockets(one screw in each and two electrical plugins)simple....
Parts Used:
Turntable Coupler Light Socket - 250V 75W
  • Kerry from Davis Junction, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
18 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Grill needed replacing - it literally fell apart
The grill is located on the top of the microwave - above the door. The plastic seems to have just deteriorated - the plastic around the screws just cracked. There was also another crack on the side of the grill assembly. The micrawave is fairly new (4 years old) and we don't use any harsh cleaners on the plastic grill because it has never required it. The unit is also vented to the outside - so it doesn't get exposed to alot of heat. To put on the new grill - it took 5 minutes, two small phillips head screws. My only question is why did the plastic just fall apart
Parts Used:
Vent Grille
  • Donald from Bellingham, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
20 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Glass turn table made loud noise while turning then stopped turning
This repair could not have been easier! The website was great at helping to identify the problem and the part needed. Users discribing how they did the repair gave me the confidence to do it myself. I got the part the day after I ordered it, installed it and my microwave was a good as new! It was as simple as unscrewing seven screws to remove the bottom of the microwave. Then two more screws to remove the part. Unplug the broken drive, plug in the new one and screw everything back together! Don't forget to unplug your microwave before you begin.

Great website!
Parts Used:
Drive Motor
  • Linda from Le Claire, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
17 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Changing the bulb that illuminates the cooktop
Loosen screw holding glass cover plate in place over bulb. Glass cover plate will swing down. Unscrew bad bulb, replace with good bulb, reset glass cover and tighten screw.
Parts Used:
Light Bulb - 40W 130V
  • LUCY from BALLWIN, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
21 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace Door Film
remove old film, apply new film. real easy. no magic
Parts Used:
Microwave Door Film
  • Roy from Alta Loma, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
21 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave stopped working it lost complete power
Upon taking the faceplate off (unplugged power source first) I found one of the wires going to the THERMO SW-TCO SENSE TEMP was completely burned away. I cut back the wire and spliced a new section with heat shrink connectors and I replaced the THERMO SW-TCO SENSE TEMP. I plugged the power back in and it works great.
Parts Used:
Thermal Fuse
  • Thomas from HAMPTON BAYS, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
17 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Grinding Noise In Motor
Removed upper cover. Removed screws in cover plate & motor mount. Removed inner cover with pop screw inside microwave. Reversed procees to install new motor.
Parts Used:
Stirrer Motor
  • MARK from VALLEJO, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
17 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
After closing door the display panel must be tapped on to keep the unit operating.
The switches are not the problem! The problem is in the tolerences of the latch housing. I have ordered two new housings (Upper & Lower) and will see if the tolerences are closer. If not I will try epoxying a shim to the plate that operates the microswitches. The other option is to file the mounting slots of the housing to allow adjustment, which would be iffy,keeping them from moving with use. The exploded drawings really need to be clarified. The scale is way too small. It was extremely difficult to pick out the individual parts of the mechanisiam.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • Paul from San Jose, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
25 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
rotating glass tray was grinding and not turning.
I first took the filters of the exhaust and then removed the screws on the bottom of the combination microware hood fan. Once the 6 retention phillips head screws were removed from the bottom of the microwave, and the hinged bottom "door" lowered the motor was exposed. I removed the motor by removing the two phillips screws and unplugged the motor. The hardest part was finding a replacement on the net because most shops did not give enough details or pictures to know if a part was exchangable or a replacement. Partselect.com listed the parts, motor voltage, and had pictures so that I was comfortable with ordering. The part arrived the day it was scheduled to and I simple reversed the process and within 5 minutes I had the microwave motor in and back together. It is nice to do business with a place that also gives you a returns policy upfront.
Parts Used:
Drive Motor
  • Michael from Midland, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cooling fan gremlin
Pulled micro off the wall, took side/top cover off to get at the cooling fan behind the control panel. Unplugged wires and removed control panel to ease the removal of the cooling fan. Two screws hold the fan. Pretty easy job.
Parts Used:
Magnetron Fan Motor
  • Alvin L. from Wasilla, AK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
17 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable coupler broke due to plastic wrap getting tangled
Turntable coupler broke due to plastic wrap getting tangled, top part came out easy, other piece that broke did not come out so easy. Placed used stocking over shop vac end and vacuumed out broken piece, replaced with new coupler. Done.
Parts Used:
Turntable Coupler
  • Eric from CINCINNATI, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave made squealing noise when on. Fan was worn out.
This particular microwave is the over the range type, with an exhaust fan at the top and charcoal filters over the stove. Then to the side is the control panel for the microwave oven. You have to get into this to get to the fan. To do this, you have to take off the vent trim at the top of the microwave. Two screws. Open the front door and gently wiggle once the screws are out. Care must be taken with this because over time the channels that the screws go in can break, and then once that happens there's nothing to hold the vent into the oven. (I've replaced this once when both screw openings simply crumbled). Once it's off, there is a screw under it at the top of the control panel that needs to come out. There's another screw at the bottom of the control panel. Then, you slide the panel up about a half inch and then you can pull it out. After that, you can see the fan in there. There are two screws holding it in and a bunch of wires all around it. Pull out the multipin connector on the fan. There is a second plug-in wire that you may need to use pliers to get a grip on it. Pulling out a couple other nearby wire connectors will help loosen it all up so that you can move the wiring harness out of the way and tilt the fan out and remove it. Looking at the old fan, the bearings were tight and worn out, and that was the problem. It's not a particularly well made fan. Very simple open-frame motor with moving parts exposed, so it probably through the years ingested oil vapor from cooking, etc. Tilt the new fan into position, put the two screws back in and re-insert the wire connectors. Then all you need to do once all the wiring is neatly dressed again is put the panel back on, the two screws top and bottom, and lastly reinstalling the long vent at the top, (two long screws). Do that, and you're done. The microwave sounds fine now and works great.
Parts Used:
Magnetron Fan Motor
  • Richard from PORTER RANCH, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken handle
Removing the inner plastic was fairly easy but take care that you don't crack the edge by being too aggressive. After removing the frame I realized that the handle had not only broken where the screws attach to the handle but also pulled through the frame. I needed to add a couple of small washers and a little epoxy to hold it firm. Works great now.
Parts Used:
Door Handle - Black
  • bernard from Puyallup, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud noise from inside microwave
I initally thought the problem was the turn table motor but after installing that motor & not being successful I realized the problem was the stirrer motor.Removing & insalling that motor was a bit more challenging but worth the effort as I saved either the cost of a repair technician or the puchase of a new one.The microwave is back in service & running fine.
Parts Used:
Stirrer Motor
  • Allan from Huntley, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
16 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the EMO3000HBB03