low temp due to frost built-up on freezer coils.
UNPLUGGED REFRIGERATOR..
removed top shelf in refrigerator..removed back plate covering controls..removed two screws holding control housing..removed two screws holding defrost timer..unplugged defrost timer and plugged new timer in..put all parts back in place with procedure reversed..
Parts Used:
Defrost Timer
  • alfred from petersburg, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
Parts Used:
Light Switch
  • Robert from Coto de Caza, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would not close properly
I emptied everything from door compartments.I removed the top cover of the door pivot with a phillips screwdriver. I removed the two screws that that hold the pivot bracket with a 8 mm socket. Lift the door off the bottom pivot bracket. Remove the old bottom pivot bracket with an 8mm socket and replace it with the new cam bushings.You must replace both bushings on the bottom of the door and on the bracket that mounts to the base of the body of the refrigerator. Reinstall the door and screws .The doors should be level with each other if they are installed properly.If not check the freezer door .The bushings may be worn on that door also.
Parts Used:
Bottom Hinge Assembly
  • Laurence from Dearborn, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights blown out
replaced lights in refrigirator and freezer
Parts Used:
Light Bulb - 40W
  • Gerald from WINTERVILLE, GA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The bottom hinge broke
First, I removed all items on the door shelves and the shelves themselves to reduce the weight of the door. The door came off by itself because the bottom hinge had broken. Then I placed the door horizontal on the kitchen floor to have easier access to the bottom of the door. I had a piece of blanket under the door to prevent any scratch. I then removed two screws holding the door closing cam and shim and replaced them with the new parts. Next, I removed the base grill to have easy access to the old hinge assembly on the refrigerator itself. All I had to do was grab it firmly at either end and pull it forward. I replaced the hinge assembly with the new one. I removed the cover on the top hinge assembly and removed the two screws that secured that hinge (I was not able to put the door back without removing the top hinge assembly). All down hill from this point. Time to reinstall the door, aligning the bottom of the door cam over the hinge assembly and setting the door down on it making sure the door sets on the hinge assembly cams. To the top of the refrigerator. reinstalled the top door hinge assembly and cover (I had to make sure the door was standing straight vertically before I tightened the nuts), I also put a small amount of white grease into both the top and bottom hinges.
Parts Used:
Bottom Hinge Assembly
  • W from Northbrook, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
After replacing the door seal we saw that the door still did not seal because the lower hinge cam was worn.
Propped the door up with wood so we could change it without removing the whole door.
Removed &Replaced the cam and bracket quite easily. It did require 2 people, one to help hold the door while the other did the work.
Parts Used:
Bottom Hinge Assembly
  • June from Maple Valley, WA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Water Leak
Icemaker waterline leaking inside by the grommet where the water line comes in the refrigerator . First removed the water line from grommet . Then removed grommet by hand from the fridge. Last, reversed prodedure.
Parts Used:
Fill Tube Grommet
  • BRIGIDA from MIAMI, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
Parts Used:
Light Switch
  • Eileen from Coto de Caza, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator contents began to freeze up
I first rolled out the refrigerator, unplugged it, and emptied the freezer contents into a cooler.

Then removed the shelving (side by side freezer / refrigerator) and the four screws holding the back panel.

The coil and defrost heaters were covered with ice, so the paint heat gun made quick work of defrosting them.

The heaters were held in by two screws each, so replacing them with the new units took little time.

Then it was a matter of routing the wiring and thermostat to the top of the coil, and plugging them in.

Replaced the back panel and shelving, and plugged in the refrigerator.

Saw that everything was operating, so I rolled the refrigerator back in place, and replaced the freezer contents.

In a few hours everything stabilized in the refrigerator and we were back to normal.
Parts Used:
Defrost Heater with Thermostat
  • Andrew from Jefferson, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Severe Ice Build Up, But Freezer Temperature Inadequate
I followed the troubleshooting instructions for freezers with ice build-up. First defrost the freezer. This makes a huge mess. The tray for water buildup is very small. I suggest covering the hole so no water gets to the tray and collecting the water as it melts in the freezer. (DO NOT pry the ice off with a knife. I did that when I was 14 and punctured the freon lines.) After the ice was gone inside the freezer, I removed the back panel of the freezer (a pair of 5/16" nuts on the bottom and a pair of #2 phillips screws at the top). The panel will then just pull straight out. Make sure the ice has melted from behind the panel as well before testing any of the components.

First component to check is the defrost timer. Pretty straight forward, using the instructions on the PartSelect home page and a multi-meter (looking for continuity or the lack there of). You need to remove it and check it out of the fridge. In my case the defrost timer worked correctly (bummer since it was much cheaper than the defrost heater kit). Next step was to test the Defrost Heater. I used a common since approach which was not mentioned in the instructions. I manually turned the defrost timer until it clicked. Then I put my hand next to the glass tubes that incased the heater elements. They did not get hot. I then turned the defrost timer until it clicked again. Again, the heater elements did not get hot. Since there are only two setting on the timer, it means the defrost heater was broken. If you can hear the refrigerator/freezer running, then you are not in defrost mode. Turn the thermostat for another click. All noise will stop...and heat should be found at the tubes (behind 6" thin tin covers), if they are functioning.

Removing the defrost heaters and thermostat was simple. There are four #2 screws (2 on each assembly). The thermostat is just clipped on. It is impossible to put the defrost heater assembly in wrong. Put the panel back on and your ready to go. The 30-60 minutes is not repair time but de-ice and repair time. I used a space heater to speed up the de-ice process.
Parts Used:
Defrost Heater with Thermostat
  • Randall from Ashburn, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Closing cam disintegrated
Removed everything from the refrigerator door. Removed the screw holding the cover over the top hinge. Removed the two (8mm) bolts holding the top hinge to the refrigator. Removed the door. Removed the plastic grill/cover and the two (8mm) bolts from the lower hinge assembly. Installed the new hinge assembly. Replaced the closing cam (included in the hinge assembly kit) on the bottom of the door. Put the door back on the lower hinge. Installed the upper hinge. Adjusted the door and tightened the bolts on the upper hinge, and replaced the hinge cover. Done!
Parts Used:
Bottom Hinge Assembly
  • Larry from Renton, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would drop down when opened
Removed the door by removing the top hinge and lifting it off the broken bottom hinge/cam assembly. Removed the broken hinge/cam assembly found out why the cam broke the doorstop was bent so I had to order the doorstop also. The ordering of the parts was so easy. They shipped them on Monday and they arrived the next day. I will use Parts Select again
Parts Used:
Bottom Hinge Assembly
  • Donald from Lauderhill, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
a fan blade broken causing it to make a loud noise
we took off the old one and replaced it.
Parts Used:
Evaporator Fan Blade Kit
  • Marnie from Denver, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Produce side of the refridgerator was warm, freezer side cold.
removed the back of the freezer unit and replaced the defrost heater and thermastat. took the controls out of the produce side and replaced the defrost timer.
Parts Used:
Hinge Cam Riser
  • Mike from Lawrence, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
coils frozen freezer 18 degrees refrigerator at 68 degrees
Checked continuity of defrost timer and marked to make sure was cycling. When checked continuity of top defrost tube-it was fine but, soon as looked at bottom tube could see problem. Tube was black, no continuity, and left side of tube was separated from the rubber connector, thought obviously water entered tube during defrost and shorted unit and since wired in series with bottom unit not working would not allow power to reach top unit. New replacement kit simple to install-4 phillips screws hold the 2 units in place- thermostat clips to top coil and wiring runs along the coils to top with thermostat- connect 3 prong plug to existing hook up and put on cover plate with 2 cap screws and 2 phillips the job was completed, IMMEDIATE RESULTS. Suggestion- even though tubes are available separately the time to rewire into the existing harness to save couple $$ is not worth it- the other unit will have lost some continuity in comparison to new install so will have tendency to go bad quickly-spring for the difference and have piece of mind for many years to come for replacement of this part. 2 day standard shipping by ground right to door and the little woman thought I was superman of repairs. Since this model was built by GE for Sears- check on Sears was double and inquire in tech repair was double again-Part Select is quality,speed in processing and makes tight budget go the distance.
Parts Used:
Defrost Heater with Thermostat
  • JAY from EVERETT, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!