Failed Icemaker

  • Customer: GARY from PARRISH, FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 15 of 30 people found this instruction helpful
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.

leaking water / icemaker valve

  • Customer: Lorry from Bentonville, AR
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 9 of 12 people found this instruction helpful
Simple. UNPLUG THE FRIDGE. Remove set screw holding valve to frame, switch hoses one at a time into new valve, switch wires one set at a time from old to new, re-attach the new valve, turn on water , plug in fridge, check for leaks. 2-minute job.

Very low flow from water dispenser, hollow ice cubes, broken ice dispenser helix

  • Customer: Osvaldo from Miami, FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench (Adjustable)
  • 9 of 12 people found this instruction helpful
Unplugged refrigerator. Removed cardboard cover, vacuumed lint from coils and equipment area. Removed dual valves and labeled the four electrical leads with masking tape. Cut off the end of water lines to dispenser and ice maker to remove threaded connections (New are simply push on). The water leads are of different diameters, so there is no confusion.
Decided to replace water line at the same time so bought a plastic replacement for less than $10, removed old copper line and replaced it with new. (Original plumber used a custom made line with a smaller diameter and this may have contributed to the low flow).
Connected all lines and wires (had to use adapter supplied with valve for two of the leads which are of different connector widths than original) and secured valve and back panel. Had to bedn the valve mounting plate somewhat to allow it to fit (this is also a little different from the original).
After installation, it takes a little time to refill the lines until proper flow is established both at the dispenser and the icemaker.
Replacing the Helix took completely disassembling the ice drawer, Take your tiime in doing this as there are many parts that fit in only one precise way. This helix replacement took about 20 minutes total.

fridge quit coolingg / freezing

  • Customer: JEFF from HAMPTON, GA
  • Difficulty: Really Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 8 of 10 people found this instruction helpful
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)

bucket drive shaft disengaged from motor drive

  • Customer: Paul from Ashton, MD
  • Difficulty: Difficult
  • Time to Complete: More than 2 hours
  • Tools Required: Pliers, Screw drivers
  • 10 of 14 people found this instruction helpful
This is a 25 year old unit. The ice bucket had warped over time causing the face plate to move forward of its ideal position pulling the entire assembly out of the drive. Removed dispensing unit face assembly. Removed drive shaft assembly. Replaced all washers. Reversed old broken drive cup. Married old drive cup to new drive cup...lining up drive slots. Drilled 6 ea. 3mm holes evenly spaced around circumference into the face of the old drive cup. Fastened drive cups together in vice and with C clamp...then using phillips head screws installed 3 ea. from opposing entry points on each side of this homemade shaft extender. This "mechanism" increased the effective length of the dispensing shaft assembly allowing for a proper fit of the drive shaft to the motor drive connection. Unit now works perfectly. Total cost @ $40.00 and two hours work which would have taken less than one hour if I had remembered to install the ice bucket seal the first time. New ice bucket would have cost @ $185.00. Home warranty does not cover ice makers or any of the associated parts. DIY...it isn't that difficult.

Existing light switch was hard to remove.

  • Customer: Stephen from Jupiter, FL
  • Difficulty: A Bit Difficult
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 10 people found this instruction helpful
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.

Ice Maker wouldn't work, water tube freezing up, water leaking onto floor

  • Customer: Drew from Spring Lake, NJ
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 9 of 14 people found this instruction helpful
My problem was that the tube from the water valve to the ice maker was freezing when the valve was malfuntioning and sending more water, causing it to back up and freeze in the reception tube. Then the plastic water tube from the valve to the freezer seperated and water was leaking onto the floor. By reading the repair storyies on the Partselect website I learned that the water valve was not working correctly and needed replacing. I ordered the replacement part on a Wednesday evening and had the part at my house via FEDEX on Saturday morning. It took me about 20 minuttes to complete the entire repair.
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!

Fridge wouldn't start

  • Customer: Patrick from Medford, NY
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 8 of 11 people found this instruction helpful
Removed cowling unpluged timer and pluged in new one.
Great Service, got part in one day

freezer not frezing properly frost buildup

  • Customer: Bill from Columbiana, AL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 6 of 6 people found this instruction helpful
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.

refrigerator did not cool

  • Customer: Carl from Kent City, MI
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 8 of 12 people found this instruction helpful
i put a new evaporator motor in and now it works fine

Will not make ice

  • Customer: GEORGE from ELIOT, ME
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 15 people found this instruction helpful
Bing , Bang, Boom.

compressor not starting

  • Customer: H.K. from Seagoville, TX
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 12 people found this instruction helpful
Refrigerator is not cooling. Light and fan working. Changed the capacitor.. Still not cooling. Back to discovery mode.It may be the timer
Certainly not PartSelect's fault. They have great service.

Fan had quit; needed replacement.

  • Customer: John from Divide, CO
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 8 of 13 people found this instruction helpful
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues

Refrigerator water dispenser tube (5/16"OD) broken at the back by valve

  • Customer: Peter from Marietta, GA
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Wrench set
  • 6 of 7 people found this instruction helpful
Tube was too short so I used the union to attach additional tubing to reach the valve at the lower rear of refrigerator

Refrigerator compartment warm, Freezer cold

  • Customer: Hop from Houston, TX
  • Difficulty: Really Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 6 of 7 people found this instruction helpful
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.