Quick Question!

Have you ever purchased from PartSelect.com before?

Models > CSC24DRAAD > Instructions

CSC24DRAAD Hotpoint Refrigerator - Instructions

All installation instructions for CSC24DRAAD parts

These instructions have been submitted by other PartSelect customers and can help guide you through the refrigerator repair with useful information like difficulty of repair, length of repair, tools needed, and more.

All Instructions for the CSC24DRAAD
31-45 of 733
Search Instructions
Keep searches simple, eg. "belt" or "pump". Need help?

Water Leak From The Ice Make - Water All Over The Frig

  • Customer: David T from Irvine, CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench (Adjustable)
  • 14 of 15 people found this instruction helpful
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to identify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.

Ice was melting and freezing in bucket

  • Customer: John from Lodi, CA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 14 of 17 people found this instruction helpful
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.

Refrigerator to warm freezer ok

  • Customer: Christopher from Madison Heights, MI
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 13 of 15 people found this instruction helpful
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.

dirty ice from rusty auger

  • Customer: William from Chesapeake, VA
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 13 of 15 people found this instruction helpful
Removed old bucket/auger assy from frig. Removed 4 + screws from front cover. Put front cover on new bucket/auger assy. Reinstalled in frig.....done. now have clean ice.

meatal parts were rusted

  • Customer: Allan from Pleasanton, CA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 20 of 36 people found this instruction helpful
the part is fairly easy to take apart, however pay close attention to how things fit and go together. It took me sometime to figure the reassembly out due to my lack of close attention to taking it apart. other than that it is simple.

Refigerator door would no longer self close

  • Customer: Melvin from Philomath, OR
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 12 of 13 people found this instruction helpful
Moved all items from door storage into refrigerator shelves. Removed top hinge cover held by single screw and top hinge plate held by two bolts. Lifted up door to clear bottom hinge pin and removed door. Covered open front of refrigerator with plastic wrap to keep cold in refrigerator with door removed. Laid door on kitchen counter top and removed bottom hinge assembly held on by two bolts. Replaced upper cam located on bottom of door and screwed the hinge assembly back on to bottom of door (helps to keep the three plates in same sequence and note the position of cam). Drilled out the rivet that holds the lower cam to the bottom hinge pin. Removed old lower cam and and replaced with new cam and secured to lower hinge assembly with pan head screw and nut (instead of rivet). Replaced door back onto lower hinge pin and secured upper hinge pin with original bolts. Placed cover on upper hinge assembly and secured with original screw. Removed plastic wrap from front of refrigerator and moved the items that originally were stored in the door back to provide weight needed for door to close properly. All done and the door works like new, and all in less than 45 minutes. Would have been a more difficult job without the pioneering of people on this site. Thanks to all!

The Duct Door allowing ice to come out broke and so the freezer was open to the room.

  • Customer: David from Kansas City, KS
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required:
  • 14 of 19 people found this instruction helpful
The old part had fallen completely out so I just had to put the new part back into place, it was a bit tight, and you had to twist it into place, but the directions that came with the part really helped. It took me longer then it should have as I could not fit my hand up into the chute very easily. Once I figured out the layout of the chute and could get the part in the proper place to twist it into place it worked well.

This part on refrigerator went out, wouldn't dispense water.

  • Customer: Glen from Harrisburg, OR
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers
  • 13 of 18 people found this instruction helpful
I removed the back cover on the refrigerator. Unbolted the unit. First of all I unpluged the refrigerator. Took off the two electrical connections and removed the input and output water lines. I then reversed this process when I installed the new part. It was real easy.

Frig would stop working every so often. Lots of food got spoiled.

  • Customer: Rene from Bronx, NY
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 11 of 12 people found this instruction helpful
Got part overnight. Unscrewed cover plate at top of regerator compartment, disconnected old part, connected new part. Screwed back plate. Voila!

I saved a bunch of money!

Compressor overheating - Fridge not Cooling

  • Customer: CHRIS from LAGUNA NIGUEL, CA
  • Difficulty: Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 12 of 15 people found this instruction helpful
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.

Replace Dual Inlet Water Valve

  • Customer: Timothy from West Windsor, NJ
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers, Wrench set
  • 16 of 27 people found this instruction helpful
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.

New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.

water line leaking behind refigerator

  • Customer: Michael from Merrimac, MA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers
  • 11 of 12 people found this instruction helpful
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks

thermostat control not working properly

  • Customer: Betty from Lake Village, IN
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 15 of 25 people found this instruction helpful
repairman came looked it over said problem was thermostat control which was not made anymore and left charging service call $190.00 I went online found the control for $160.00 received it in 3 days put it in 30 mins later working fine.

Refrigerator Door Wouldn't Close Right

  • Customer: Anthony from Highland Lakes, NJ
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 12 of 16 people found this instruction helpful
Get 2 "door closing cams" yep. Same as some others here. Found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. Very easy. Bottom bracket has the broken cam riveted to it. Need hacksaw to get this off then punch it through with hammer and a screwdriver. This is the only part that took a little while. Replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half. Replace the closing cam that is on the bottom the the door as well. Even if yours isn't broken. Replace it anyway. Put door back on and done. Not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. Good luck

Motor rattled loudly

  • Customer: Robert from Kingwood, TX
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 11 of 13 people found this instruction helpful
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
All Instructions for the CSC24DRAAD