freezer freezing, refrig warm

  • Customer: Tom from Schofield WI
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 10 of 13 people found this instruction helpful
pretty straight forward,removed threw screws to replace the defrost timer and reverse the procedure. To replace the defrost unit 1st removed metal back plate in freezer. Step 2 defrost freezer. step 3 remove four screws that hold defrost elements in freezer compartment. Step 4 install new defrost elements and secure back in place with four screws. step 5 optional read old defrost heaters with ohm meter to confirm the defective part. step 6 plug back in frig and enjoy a cool brewski ahhhhh. By the way only one defrost element was bad (open) but as mentioned in literature which came with new derost elements I replaced both of them. Thanks again for all the help on this, saved me $2000 on a new frig.

Refrigerator to warm freezer ok

  • Customer: Christopher from Madison Heights MI
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 9 of 10 people found this instruction helpful
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.

Refigerator door would no longer self close

  • Customer: Melvin from Philomath OR
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 9 of 10 people found this instruction helpful
Moved all items from door storage into refrigerator shelves. Removed top hinge cover held by single screw and top hinge plate held by two bolts. Lifted up door to clear bottom hinge pin and removed door. Covered open front of refrigerator with plastic wrap to keep cold in refrigerator with door removed. Laid door on kitchen counter top and removed bottom hinge assembly held on by two bolts. Replaced upper cam located on bottom of door and screwed the hinge assembly back on to bottom of door (helps to keep the three plates in same sequence and note the position of cam). Drilled out the rivet that holds the lower cam to the bottom hinge pin. Removed old lower cam and and replaced with new cam and secured to lower hinge assembly with pan head screw and nut (instead of rivet). Replaced door back onto lower hinge pin and secured upper hinge pin with original bolts. Placed cover on upper hinge assembly and secured with original screw. Removed plastic wrap from front of refrigerator and moved the items that originally were stored in the door back to provide weight needed for door to close properly. All done and the door works like new, and all in less than 45 minutes. Would have been a more difficult job without the pioneering of people on this site. Thanks to all!

Ice Maker was leaking all over freezer compartment

  • Customer: Mary from Langhorne PA
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 9 of 11 people found this instruction helpful
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try to stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.

Failed Icemaker

  • Customer: GARY from PARRISH FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 14 of 26 people found this instruction helpful
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.

ice would not dispense

  • Customer: john from montgomery TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 10 of 14 people found this instruction helpful
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new.
thanks.

The refrigirator light would not come on.

  • Customer: Jania from Novato CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 11 people found this instruction helpful
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.

water valve leak

  • Customer: Scott from Columbus IN
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers, Wrench set
  • 8 of 8 people found this instruction helpful
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure It Is Right Because You Only Get One Shot At It.

Flapper was stuck open. Old and warped.

  • Customer: James from Virginia Beach VA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 10 of 15 people found this instruction helpful
Replaced flapper

Rust on parts

  • Customer: Sally from Allen TX
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 8 of 9 people found this instruction helpful
I recommend taking a picture of any part before it is removed. Remove all screws. Use the diagram provided by this site for the dismantle of the ice bucket parts. I replaced the plate and ice auger. I found that my rusted screws for the plate would not fit the new plate, so I bought replacement screws at Home Depot. After I got all the blades off, I realized that I should have probably replaced a couple of them as well. Next time I decide to repair an item, I will totally inspect all parts before ordering. Order was shipped immediately. Postal Carrier showed me why he dropped off at another location which caused a delay of a couple of days. Not the senders problem. I had a hard time remembering just how the rod on the side was suppose to fit. I should have taken a picture. (laughing) I finally figured it out. My ice maker is as good as new. So happy I did this. My husband always says: " Just get a new refrigerator." I was raised to fix things until they just die. He was so impressed that I was able to follow the diagram and re-install the ice bucket. All is great. I will use this site again. They are a great company. I am sure I saved hundreds of dollars for a repairman who would have replaced the whole unit and not taken the time for the repair and replacement of parts. This was just "as easy as pie".

CAMS ON FREEZER DOOR BROKE

  • Customer: WALTER from FROSTBURG MD
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set, Wrench(Adjustable)
  • 8 of 9 people found this instruction helpful
REMOVED TOP HINGE AND ELECTRICAL CONNECTOR (FREEZER DOOR HAS ICE AND WATER DISPENSERS) THEN HAD TO TURN OFF WATER SUPPLY TO UNIT AND DISCONNECT THE HOSE TO THE DOOR AND REMOVE THE SPRING PROTECTOR FROM THE HOSE -- THIS REQUIRED REMOVAL OF THE COMPRESSION FITTINGS IN THE WATER LINE SO SPRING WOULD COME OFF OF THE TUBE.
THEN REMOVED BOTTOM HINGE FROM THE DOOR AND USED SAW TO REMOVE THE RIVET THAT HAD HELD THE CAM TO THE HINGE, USED A NUT AND BOLT TO ATTACH NEW CAM. PUT OTHER CAM (USED TWO) IN THE HINGE AND REPLACED LOWER HINGE UNIT ON THE DOOR. THEN REATTACHED BOTH HINGES TO THE REFRIGERATOR AND LINED UP THE DOOR PUT THE SPRING PROTECTOR AND COMPRESSION FITTINGS BACK ON PLASTIC TUBING AND RECONNECTED THE WATER SUPPLY AND ELECTRIC FITTING, TURNED ON WATER TO UNIT AND PRAYED THERE WERE NO LEAKS. PRAYER WAS ANSWERED, THE WATER DISPENSER WORKED PROPERLY AND THE ICE MAKER FILLED WITH WATER SO I THEN REPLACED THE HINGE COVER ON TOP OF THE UNIT AND THE GRILL AT THE BOTTOM AND HAD A PEPSI. A FEW YEARS AGO I HAD REPLACED THE CAMS ON THE OTHER DOOR WHICH HAD NO WATER/ELECTIC CONNECTIONS AND WAS A MUCH SIMPLER JOB.

Flapper not sealing. Frost buildup on inside of freezer door

  • Customer: D from ZELLWOOD FL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 7 of 7 people found this instruction helpful
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved

Refrigerator door wouldn't close right

  • Customer: Anthony from Highland Lakes NJ
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 9 of 13 people found this instruction helpful
GET 2 "door closing cams"
Yep. same as some others here. found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. very easy. bottom bracket has the broken cam riveted to it. need hacksaw to get this off then punch it through with hammer and a screwdriver. this is the only part that took a little while. replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half.
Replace the closing cam that is on the bottom the the door as well. even if yours isn't broken. replace it anyway. put door back on and done. not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. good luck

replace icemaker

  • Customer: Conrad from Oglesby IL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 8 of 10 people found this instruction helpful
I slid the old ice maker (which was rusty) out of the freezer. I emptied the ice cubes. I unscrewed the 3 screws holding the plate to the old ice maker. I attached the original plate to the new ice maker/ auger unit with 2 screws. The new icemaker assembly did not match up with a 3rd screw hole. The 2 screws seem to be holding securely.
I reinserted the new assembly. Shorly after this nice clean ice cubes began to form. Works very well!

Defrost Thermostat quit working

  • Customer: Jimmy from Palmer TN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 10 people found this instruction helpful
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.