Flapper was stuck open. Old and warped.

  • Customer: James from Virginia Beach VA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 10 of 14 people found this instruction helpful
Replaced flapper

The refrigirator light would not come on.

  • Customer: Jania from Novato CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 9 of 11 people found this instruction helpful
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.

ice maker not making ice

  • Customer: Cristina from Los Angeles CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 8 people found this instruction helpful
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours

water valve leak

  • Customer: Scott from Columbus IN
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers, Wrench set
  • 8 of 8 people found this instruction helpful
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure It Is Right Because You Only Get One Shot At It.

Ice Maker was leaking all over freezer compartment

  • Customer: Mary from Langhorne PA
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 9 of 11 people found this instruction helpful
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try to stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.

freezer freezing, refrig warm

  • Customer: Tom from Schofield WI
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 9 of 12 people found this instruction helpful
pretty straight forward,removed threw screws to replace the defrost timer and reverse the procedure. To replace the defrost unit 1st removed metal back plate in freezer. Step 2 defrost freezer. step 3 remove four screws that hold defrost elements in freezer compartment. Step 4 install new defrost elements and secure back in place with four screws. step 5 optional read old defrost heaters with ohm meter to confirm the defective part. step 6 plug back in frig and enjoy a cool brewski ahhhhh. By the way only one defrost element was bad (open) but as mentioned in literature which came with new derost elements I replaced both of them. Thanks again for all the help on this, saved me $2000 on a new frig.

Motor rattled loudly

  • Customer: Robert from Kingwood TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 8 of 9 people found this instruction helpful
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.

CAMS ON FREEZER DOOR BROKE

  • Customer: WALTER from FROSTBURG MD
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set, Wrench(Adjustable)
  • 8 of 9 people found this instruction helpful
REMOVED TOP HINGE AND ELECTRICAL CONNECTOR (FREEZER DOOR HAS ICE AND WATER DISPENSERS) THEN HAD TO TURN OFF WATER SUPPLY TO UNIT AND DISCONNECT THE HOSE TO THE DOOR AND REMOVE THE SPRING PROTECTOR FROM THE HOSE -- THIS REQUIRED REMOVAL OF THE COMPRESSION FITTINGS IN THE WATER LINE SO SPRING WOULD COME OFF OF THE TUBE.
THEN REMOVED BOTTOM HINGE FROM THE DOOR AND USED SAW TO REMOVE THE RIVET THAT HAD HELD THE CAM TO THE HINGE, USED A NUT AND BOLT TO ATTACH NEW CAM. PUT OTHER CAM (USED TWO) IN THE HINGE AND REPLACED LOWER HINGE UNIT ON THE DOOR. THEN REATTACHED BOTH HINGES TO THE REFRIGERATOR AND LINED UP THE DOOR PUT THE SPRING PROTECTOR AND COMPRESSION FITTINGS BACK ON PLASTIC TUBING AND RECONNECTED THE WATER SUPPLY AND ELECTRIC FITTING, TURNED ON WATER TO UNIT AND PRAYED THERE WERE NO LEAKS. PRAYER WAS ANSWERED, THE WATER DISPENSER WORKED PROPERLY AND THE ICE MAKER FILLED WITH WATER SO I THEN REPLACED THE HINGE COVER ON TOP OF THE UNIT AND THE GRILL AT THE BOTTOM AND HAD A PEPSI. A FEW YEARS AGO I HAD REPLACED THE CAMS ON THE OTHER DOOR WHICH HAD NO WATER/ELECTIC CONNECTIONS AND WAS A MUCH SIMPLER JOB.

bad light socket

  • Customer: nancy from silsbee TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 8 of 9 people found this instruction helpful
unplugged refrigerator. removed light bulb from old socket. unsnapped old light socket and pulled it out just enough to diconnect the electrical plug that plugs into the socket . discarded the old socket and plugged in new socket. snapped in new socket into refrigerator. i watched how to do this simple procedure on you tube and decided to do it myself. easy easy easy

Failed Icemaker

  • Customer: GARY from PARRISH FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 13 of 24 people found this instruction helpful
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.

Ice was melting and freezing in bucket

  • Customer: John from Lodi CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 8 of 10 people found this instruction helpful
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.

Defrost Thermostat quit working

  • Customer: Jimmy from Palmer TN
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 10 people found this instruction helpful
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.

Refrigerator door wouldn't close right

  • Customer: Anthony from Highland Lakes NJ
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 9 of 13 people found this instruction helpful
GET 2 "door closing cams"
Yep. same as some others here. found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. very easy. bottom bracket has the broken cam riveted to it. need hacksaw to get this off then punch it through with hammer and a screwdriver. this is the only part that took a little while. replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half.
Replace the closing cam that is on the bottom the the door as well. even if yours isn't broken. replace it anyway. put door back on and done. not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. good luck

replace icemaker

  • Customer: Conrad from Oglesby IL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 8 of 10 people found this instruction helpful
I slid the old ice maker (which was rusty) out of the freezer. I emptied the ice cubes. I unscrewed the 3 screws holding the plate to the old ice maker. I attached the original plate to the new ice maker/ auger unit with 2 screws. The new icemaker assembly did not match up with a 3rd screw hole. The 2 screws seem to be holding securely.
I reinserted the new assembly. Shorly after this nice clean ice cubes began to form. Works very well!

leaking water / icemaker valve

  • Customer: Lorry from Bentonville AR
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 8 of 11 people found this instruction helpful
Simple. UNPLUG THE FRIDGE. Remove set screw holding valve to frame, switch hoses one at a time into new valve, switch wires one set at a time from old to new, re-attach the new valve, turn on water , plug in fridge, check for leaks. 2-minute job.