Freezer kept freezing up

  • Customer: Wesley from Hattiesburg MS
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 5 of 7 people found this instruction helpful
Removed the cover for the evaporater coils and let them defrost. Then took the old heating element out by removing two screws on the bottom element and two screws on the top element. Unplugged it and removed it from the unit. Then repeated the reverse of the procedure, installing the new unit, no wires to splice only one plug and four screws.

freezer not frezing properly frost buildup

  • Customer: Bill from Columbiana AL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 4 of 4 people found this instruction helpful
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.

Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.

  • Customer: Terry from Simi Valley CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 4 of 4 people found this instruction helpful
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope

broken fan blade in the freezer compartment

  • Customer: John from Cumberland MD
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers
  • 5 of 7 people found this instruction helpful
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.

excessive door swing

  • Customer: PETER from ENGLEWOOD NJ
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Wrench(Adjustable)
  • 4 of 5 people found this instruction helpful
Removed the top hinge and the door.
Removed door stop held in place by 2 screws, installed new door stop.
re-installed door and top hinge.
Easy once the correct diagnosis was made
It would have been nice if I could have e-mailed you the symptoms and received an accurate diagnosis. As it developed, I initially replaced the door cam before realizing that the door stop itself had broken.

Existing light switch was hard to remove.

  • Customer: Stephen from Jupiter FL
  • Difficulty: A Bit Difficult
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 4 of 5 people found this instruction helpful
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.

All the shelving rails had cracked, vegetable and meat storage bins dropped.

  • Customer: Wayne from Warner Robins GA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 4 of 5 people found this instruction helpful
Removed the storage bins, unscrewed the old rails, screwed in the new rails and saved a Sears service call plus their mark up on the parts. Estimated savings was about $100.

Fan had quit; needed replacement.

  • Customer: John from Divide CO
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 6 of 11 people found this instruction helpful
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues

support clip broken.

  • Customer: Arturo from Killeen TX
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 7 of 14 people found this instruction helpful
After figuring out how to remove the old broken clip, replacement was easy. Had to use a small putty knife to open the release on the bottom underside of the clip(between the clip & the refrig) . By looking at the replacement piece it was easy to figure out.

Refrigerat

  • Customer: Charles from Rose Bud AR
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Wrench set
  • 4 of 5 people found this instruction helpful
rerfrigator side not cooling After determinating that the defrost timer was running I turned it to defrost and watched tosee if frost started to melt. When it didn't I checked the heater with ohmeter, checked OK, so the only other component in the defrost system is the thermostat. Then just a matter of cutting and splicing wires and snapping the new thermost in place

cam closing washer broken

  • Customer: David from Elk Grove CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set
  • 3 of 3 people found this instruction helpful
I propped up the door with 2x4 and shims to be level with the freezer door. Then removed the 2 screws holding the hinge to the main unit. Then removed the 2 screws holding the cam washer to the door.
Replacement was the reverse of disassembly. Be sure to tighten screws almost tight until both pieces are located correctly then fully tighten. Lift up refrigerator door slightly to remove shims and wood block.
I did the replacement myself but was nervous that the door would fall off the block and shims. I recommend having another person hold the door closed during the process.

low temp due to frost built-up on freezer coils.

  • Customer: alfred from petersburg NJ
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 4 of 6 people found this instruction helpful
UNPLUGGED REFRIGERATOR..
removed top shelf in refrigerator..removed back plate covering controls..removed two screws holding control housing..removed two screws holding defrost timer..unplugged defrost timer and plugged new timer in..put all parts back in place with procedure reversed..

Door would not close properly

  • Customer: Laurence from Dearborn MI
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 3 of 3 people found this instruction helpful
I emptied everything from door compartments.I removed the top cover of the door pivot with a phillips screwdriver. I removed the two screws that that hold the pivot bracket with a 8 mm socket. Lift the door off the bottom pivot bracket. Remove the old bottom pivot bracket with an 8mm socket and replace it with the new cam bushings.You must replace both bushings on the bottom of the door and on the bracket that mounts to the base of the body of the refrigerator. Reinstall the door and screws .The doors should be level with each other if they are installed properly.If not check the freezer door .The bushings may be worn on that door also.

door would not close, had dropped down.

  • Customer: bert from Spartanburg SC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Wrench(Adjustable)
  • 3 of 3 people found this instruction helpful
Was able to pull the door up to the normal position, then blocked in place with 2 2x4's. Easily removed the hinge assemble and the door closing cam, which had broken in two.
bolted on the replacement parts in 10 mionutes and the door was a good as new: peice of cake!!!

Refrigerator would begin to lose it's cool and we saw ice caking on the bacjk panel of the freezer section.

  • Customer: Charles from Edison GA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 4 of 6 people found this instruction helpful
We had to empty the freezing section, remove the 4 screws that held the back panel and defrost the coils. Then with the diagram we got from the internet, we removed the defroster and easily installed the new one and put the back panel back on. We did find later that it was still icing over so I ordered the thermostat and we installed it today.
It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.