intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Parts Used:
Condenser Fan Motor Kit
  • Honz from Tucson, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was running very cold
Unscrewed the right control knob. Removed the left temperature control knob (there is no screw holding it), removed one screw to rear of small panel then pried open from the rear of the small panel, there are two plastic tabs in front of the small panel holding it in place. Unscrewed the failed control unit and replaced it with the new one. Replaced the small panel and screw then the left side control knob, making sure of the alignment in the "off" position as the knob has to be pressured into a clamp arrangement on the cold control thermostat. Re-screwed the right knob into place, as well.
Parts Used:
Cold Control Thermostat
  • Henry from Newland, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Parts Used:
Condenser Fan Motor Kit
  • Donald from Strafford, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Socket set
Was this instruction helpful to you?
Thank you for voting!
blower motor was going out
just had to remove the fan motor the hard thing is getting down to it
Parts Used:
Condenser Fan Motor Kit
  • Robert from Batavia, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
leaking water tank
removed the old tank replaced with new tank I had to cut the end of each water line to make it fit into the fitting. check for leaks. It is good to run a bit of water through the tank to get out the air
Parts Used:
Water Tank Kit with Unions
  • john from redmond, OR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
Not cooling properly/ door divider getting hot.
The video of the repair is a helpful guide, but my refrigerator has the compressor very close to the condenser fan motor. With the compressor comes the copper tubing that is all in the way. I had to carefully bend them now and then to allow me to get my hands in position. The how to is easy, but the working with tools in cramped quarters was difficult. I think my Maytag side by side model makes for this job to be difficult, maybe yours may not be so bad. I took a couple of hours to complete. After the first hour, I covered the bare wires, and plugged the frig back in so it could do some cooling. I placed a small in front on the condenser to blow across it. Had a little break, then finished the job.
Parts Used:
Condenser Fan Motor Kit
  • Timothy from Granite City, IL
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Wrench set
Was this instruction helpful to you?
Thank you for voting!
Temp in the refrig side was too high. Freezer OK
I unpluged the refrig, removed the shelves and the back panel on the freezer side of the unit. This exposed the fan motor and fan blade. I removed two screws holding the fan unit in place, unpluged the wires connecting the fan unit to power, and then removed two other screws securing the fan motor to the bracket. I removed the fan motor blade from the old unit and installed it on the new fam motor. I replaced the fan unit into the bracket, pluged the wires back into the fan motor and secured the motor to the refrig. Replaced the back panel and shelves, pluged the refrig into the wall.....easy.
Parts Used:
Evaporator Fan Motor - 115V 60Hz - Blade NOT Included
  • James from Sacramento, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Two problems- auger motor and ice bucket rack
Had to replace ice bucket rack because auger motor broke the plastic backing and also the auger motor because shaft was bent on old auger motor. Just followed directions on web site to do repair.
Parts Used:
Ice Bucket Auger Drive Motor Kit
  • John from Greenville, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer was not Defrosting
I have an Amana freeze and I followed the procedure in the video. Which is very good! However on the Amana Model there two slight differences in the procedure that I felt I needed to do. The first one is, the condenser fan bracket is attached to the Freezer chassis with 4 screws, not three. The removal and installation of the back screw by the fan is a bear. I removed the other three and it allowed me to rotate the fan slightly to get more access to the fourth and did same on installation by just starting the 4th screw and then tightening it later. The second issue was my new fan hit the housing when I spun the fan. When I looked at the old one. It had a phenolic washer, between the fan and motor which spaces the fan out about a washer thickness from the motor. When I tried to remove the old one it broke in four pieces due to age. So, I made my own with a washer that I super glued to the motor housing after carefully centering it on and clearing the motor shaft . Seemed to work with out any more noise or balance issues...Thanks, your delivery was blindly fast and video was great!
Parts Used:
Condenser Fan Motor Kit
  • Andrew from Pinckney, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Ice Dispenser drive ring was broken
I pulled the dispenser bin and emptied the existing ice (the maker worked, the dispenser would not dispense). Though there appears to be more, there are about 4 (reciting from memory)very small tap screws holding the front of the dispenser unit to the bin. The dispenser activation screw mounts over protruding items at each end. The item at the back (away from the dispenser gear package) is the drive ring that was broken. The drive ring is a small plastic cup that inserts into an opening at the back of the bin (female side to the rear) and slides into the distal end of the activation screw on the same end. One must line up the small slot on the inside of the drive ring with the end of the screw. Slide the assembly together (make sure that the cube/crush switch rod is properly clipped in place with the return spring hooked to the clip), GENTLY install the 4 or so screws and return he assembly to the freezer. It should work flawlessly. Elapsed time: 15 - 20 minutes.
Parts Used:
Ice Bin Drive Ring
  • Donald from Highland, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
light socket in fridge corroded, kills light bulbs
The old light fixture and socket were easily removed. This was done with the power connected, but I already knew the switch didn't need to be handled. The solderless connectors are all insulated, so I just had to be careful. The new socket would not accept the connector for the "hot" (red) wire in the fridge, due to a design change. This is, of course, why you furnished a loose 3/16 inch crimpon connector. Rather than cutting the red wire (remember, the power is still connected), I obtained an insulated 3/16 connector of the opposite gender, and a short piece of red-insulated wire from an old fluorescent tube ballast, and made a jumper. The connector I provided (male) did not fit tightly in the original fridge connector, so I put a layer of resin-core solder on my male connector. You need tight connections. If the solder layer is too thick, it's easy to file down. Make sure to heat the solder sufficiently that the solidified solder is shiny and not dull gray. I used a 100-watt gun. 20 watts would probably work too. DO NOT USE ACID-CORE SOLDER OR FLUX ON ELECTRICAL WORK! I knew the switch was good, because I had checked for voltage at the socket terminals using my voltmeter, before I ordered the socket. It read 120 volts every time the door switch was open, and zero volts every time the door switch was pushed closed. A simple voltage tester would work here, too. Be very careful if you do this test or this repair with the power connected to the fridge; there is considerable potential to find yourself touching 120 volts with one hand while your other hand is touching a perfect "ground". There doesn't seem to be any choice if you want to test the switch. You do have a choice with the socket replacement - - the jumper described above. If you're not going to use the jumper approach, cut the power! If you are going to make a jumper and are not comfortable working on a "live" circuit, cut the power.
Parts Used:
Single Lamp Socket Kit
  • Lynn from Phoenix, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
Was this instruction helpful to you?
Thank you for voting!
Ice maker would stop dispensing ice,shaft would stall.
Checked the ice tray and could only find the drive ring had some breaks in the plastic. Actually did not see why this would stop the auger from turning and dispensing ice. However this was the only thing I could find wrong with the unit. I pulled the tray, removed 6 screws (star tip heads) pulled the auger forward and replaced the drive wheel, put the unit back together and its been working fine ever since.
Parts Used:
Ice Bin Drive Ring
  • David from Antelope, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Fan was making noise, Freezer temperature was erratic
First, watched video on Part Select Website. Very good. Pulled Appliance out from wall, Pulled the power plug, and removed the back shield covering the working parts of the unit. Found the fan and it was almost the same setup as on the video except that I could not get to one of the screws holding the motor in place so had to remove the entire bracket with the fan. Not too hard. Cleaned away dust and gunk around the site and noticed that the fan pulled air through a tunnel-like condenser coil that was packed with gunky lint...this is what probably killed the motor. I cleaned out the tunnel with the bottle brushes and vacuum and installed the new motor / bracket assembly. Then replaced the shielding around the fan and the back cover .panel. This is important because these form the channel that guides air flow throughout the condenser coils. This particular refrigerator has a barrier underneath which guides air flow from the front left to the condenser, through the fan, over the evaporator drip pan and out the right front. I cleaned all the lint and gunk from this area as well. I also made an air filter (cut from a furnace filter) and wedged it in front of the air entry section. This should keep the condenser coil cleaner over time but you have to remember to change the filter once a year. Probably should clean the condenser coil every 5 years as well. This unit has been very reliable over 20 years and may well go for another 20. Good luck with your repair.
Parts Used:
Condenser Fan Motor Kit
  • Dik from Quincy, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Ice maker did not make ice
This review would not be helpful if limited to this part. So I will describe the whole repair. The ice maker was first receiving too much water. This resulted in huge cubes and water dripping out of the ice maker compartment. I tried reducing the amount of water using the valve to the supply line. But then the ice maker stopped making ice. I jumped to the conclusion that the solenoid water valve needed to be replaced. The new valve was easily replaced, but no water was delivered to the ice maker. I then went to the web site and saw that 87% of the time it was the ice maker itself that needed to be replaced. I ordered one and it arrived quickly. Installing it was easy although I might never had figured out how to remove the electrical supply line to the old unit if I hadn’t watched the video. After installation no water went to the ice maker tray.

I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
Parts Used:
Double Outlet Water Valve Kit
  • Bruce from Kewadin, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
Frozen Lettuce In Crisper
My husband put in in, no problem and all is well. My husband is a mechanic for large machinery/motors so installation was no problem. Thanks, better than buying a new fridge!!!
Parts Used:
Condenser Fan Motor Kit
  • Mary E. from Chicago, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!