Icemaker producing few or no cubes and often leaving "kling-ons" on ice tray
Interior surface of ice tray felt rough & flaky (coating deteriorated) so cubes would not release.
Unplug appliance.
Remove timer cover by hand pressure @ edge.
Remove single attachment screw & bracket at lower front of icemaker.
Disconnect wiring harness from socket @ rear of compartment.
Tricky part was determining what type of connection held the other two attachment points along the long edge of the icemaker. I did not have repair manual or useful drawing but looked @ PartsDirect pic of side brackets & used a small mirror to confirm that mine were also some sort of "snap in" attachment.
Remove icemaker unit by pushing upward and outward on the unit. I takes a good bit of pressure and will pop loose, but be careful not to break attachment bracket from freezer wall.
Scavenge shut off bar and wiring harness from old icemaker once you have it out & attach to new one before installing it back in freezer.
Again, you might find a mirror useful to align those pesky snap-in brackets with the new unit.
Since you probably kept your freezer running while waiting for the part, the plastic snap-ins will be cold and brittle. I warmed them up first by applying a dampened cloth heated in the microwave to make them a little more pliable.
A good push of the new unit towards the snap-ins along with some upward force will get it stable.
Reattach the metal screw in bracket & connect the wiring harness to rear plug... and don't forget to plug the whole thing back in.
It will take awhile for the first batch of cubes dump as the timer may need to cycle completely around to get to the fill cycle... be patient.
Dump the first couple of batches of cubes just to make sure you're free of any residue.
Parts Used:
Replacement Ice Maker
  • Bernie from Diamond Bar, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
801 of 885 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.
Parts Used:
Icemaker Control Assembly
  • Daniel from Suwanee, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
557 of 665 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My refrigerator stopped cooling and the freezer section stopped freezing
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
Parts Used:
Capacitor
  • garth from forest lake, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
394 of 474 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water overflowed ice maker turnning ice bucket into solid mass of ice
My ice maker has been shedding its non-stick coating for over a year. Within the last month of so, it started pouring water into the ice bucket below, turning it into a solid mass of ice. So I purchased a new ice maker assembly. I encountered two problems not mentioned in the 21 or so do-it-yourselfer repair stories that precede this one. First problem: one of the three screws that hold the ice maker to the refrigerator wall is hidden behind the large (black) end of the ice maker and is difficult to access. Before trying to replace the ice maker, make sure you have the physical dexterity to remove that screw. Second problem: it is not apparent how to remove the wire harness that plugs into the ice maker assembly. BEFORE you can remove the wire harness, you MUST remove the large white cap that covers the black end of the ice maker assembly and then push in a retaining tab to release the wire harness. If you don't do this, the wire harness will not release. Other than those two problems, it was relatively easy to remove three screws, unplug the wire harness, transfer three small, metal parts from the old ice maker to the new, plug in the new wire harness, mount the ice maker assembly so that the water tube is in the proper position, and then re-install the three screws. The ice maker works fine now. (P.S. I was told by an expert that the real problem might be a malfunctioning fill valve. I would have replaced the fill valve if replacing the ice maker assembly had not fixed the problem.)
Parts Used:
Replacement Ice Maker
  • Harry from Grand Ledge, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
269 of 364 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Sometimes the condenser fan would start causing the refrigerator to overheat.
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Parts Used:
Condenser Fan Motor Kit
  • Tom from Franklin, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
180 of 204 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer door gasket needed replacing
Unplug refrigerator. Open freezer door. Lift the old gasket from the edge closest to the center of the door to expose the hex-head screws. Get a nut driver the appropriate size (1/4" if I remember) and loosen, but do not remove all of the screws. Once loosened, the old gasket can be removed. Slip the new gasket in just like the old one was. Lift the edges closest to the center of the door and tighten the screws. Test the fit of the new gasket by closing the door and sighting carefully down each of the four seal lines. Typically there will be spots where there are gaps, that is, the gasket is not "pulled out" enough to contact the refrigerator body. This is due to kinks that occur to the gasket during shipping. A paper that comes with the gasket notes the effect and recommends using a hair dryer to remove the kinks. Although the recommendation is to use the dryer BEFORE putting the gasket on, I used the dryer after, when I could see exactly where the gaps were. After noting the spots, open the door and with the dryer on HIGH setting, wave the hot air stream back and forth for a minute or two on each spot. Pull each spot out by hand with the hot air off and if/when the gasket is cool enough to touch but still warm. Close the door, inspect and repeat the process if necessary. I was able to achieve a good seal all the way around this way.
Parts Used:
Freezer Door Gasket
  • Jeffrey from Palo Alto, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
137 of 152 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker stopped working
With socket wrench un-screwed the 3 screws and pulled out the ice maker assembly.

Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)

However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part.

Unscrewed the motor assembly (3 screws) with phillips head screw driver.

Screwed in the new unit.

Placed ice maker back into location and tightend the bacing srews.

1 hour later ice was falling!
Parts Used:
Icemaker Control Assembly
  • Robert from Port Washington, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
135 of 154 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge and freezer didn't cool enough
I diagnosed the problem via the internet. Diagrams helped a lot. Coils were frozen over. Thawed them out overnight. Manually advanced timer and the defrost heater was operable. The defrost timer wasn't "turning" on it's own. I turned the fridge back on while I awaited the part. It worked fine for the time I had to wait. (over two weeks since I had delayed ordering the part) New timer arrived as promised. Undid 4 hex head (1/4") screws. Unplugged 4 prong connection. Plugged in new timer and replaced the 4 screws. Frigde works great.
Parts Used:
Defrost Timer Kit - 120V 60Hz
  • Peter from Eden, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
106 of 117 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frig was hot freezer was cold. Freezer was fronzen over.
The frig was hot but the freezer was cold. I opened the back of the freezer and found the condenser all frozen over. Upon inspecting the defrost thermostat I found that it was split open, as if water got into it and the froze breaking it open. I used a blow dryer to defrost the condenser. I then spent a long time trying to find the model on-line, even the manufactor said it did not exist. Partselect.com was the only place that said the model did exist. When that part came in I toke the back of the freezer out again. Unplugged the defrost thermostat plugged the new one in clipped it back on the condenser and put the it all back together. Everything is working fine now.
Parts Used:
Bimetal Defrost Thermostat
  • James from Canyon Country, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
99 of 102 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
Parts Used:
Water Fill Cup and Bearing
  • David from Chester, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
107 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator keeps running and will not turn off automatically.
Mine is a top refrigerator and bottom freezer. Whenever working with electrical applicances always disconnect the electrical power before beginning work on it. Never try to force anything. If there is abnormal resistance, use logic and determine if there is an obstable that needs to be dealt with. Loosen all screws halfway then take them off completely. Replace all screws part way and begin by inserting and starting the screws by hand then use the nut dreiver and last tighten until snug. Also, be ware that wires can get brittle and may break so handle them with care. The wires and other parts may have been frozen and defrosted many times over the life of the refrigerator. Have a flash light or other light source so you see everything well. The light will be off because you disconnected the electrical cord.

First check the defrost timer. On my unit it is located in the bottom front corner behind the removable ventilation grill. Remove about 4 hex screws. Its most useful to use a nut driver (looks like a screw driver but the tip fits different hex screws. To check the defrost timer you can turn the orange/red knob to the right and see if you can advance the timet to turn on the defrost cycle. If this works then the problem is not the defrost timer. I changed my defrost time anyway not that it was broken.

To replace the defrost thermostat, remove the food and shelves from the freezer. Use the hex nut driver and remove the hex screws from the back panel of the freezer section. If needed you will need to remove the ice maker. I don't have an ice maker. Once the back panel is removed you will see some coils, wires and other parts. Disconnect the two wires for the defrost thermostat, you can identify the defrost timer because you purchased one on-line. Carefully remove the defrost thermostat which is attached by a tension clip. The ends of the wires (terminals) may not be the same style. If needed cut the wire terminal plus two inches of excess wire from the old defrost thermostat and splice it to the new defrost thermostat. If you have a soldering iron, solder it, if not use a wire nut and electrical tape or just twist the wires together and cover with two layers of electrical tape. Now, attach the wire terminals of the new defrost thermostat to the wires that you disconnect earlier. You can not mix them up because the ends are different. Pull the tension clip slightly apart and slip onto the tubing where it came off of originally. Replace the back cover and air grill and fasten the hex screws. Attach the ice maker if you have one. Replace the shelves and food and close the freezer door. Plug in the refrigerator. It may not go on immediately. If this is the case, go to the defrost timer and turn the orange/red knob to the right and you will cycle the defrost timer to activate the freezer. Let the refrigerator run for a while, even a few hours is okay, and then it will hopefully go into the normal automatic cycle.

Other parts that may go bad and need replacing are the condenser fan that you will find by removing the cover in the back of the refrigerator. This fan runs when the refrigerator is on to cool the compressor. Also a heater coil is used to defrost the freezer. Infrequently, this part goes bad.

There is no separate cooling unit for the refrigerator compartment of the refrigerator. The cold air for both the refrigerator compartment and freezer compartment originate from the freezer. The temperature dial in the refrigerator compartment regulates the amount of cold air from the freezer that will circulate to the refrigerator.
(This just give you a clue that if the refrigerator compartment is warm the problem will still concern the freezer.)

Also, please clean off the coils that are covered with dust and webs.

This is a brief summary and depending on your level of experience and general logic and problem solving skills. This repair may or may not be easily understood. One last tip,
Parts Used:
Defrost Timer Kit - 120V 60Hz Bimetal Defrost Thermostat
  • Robert from Danville, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
91 of 94 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Parts Used:
Refrigerator Door Switch
  • Clint from Rayville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
118 of 192 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
not making ice
Installed new ice maker. It was easy - loosen two screws and unplug old wire harness. Put new unit in place. Did not realize new unit would not come with wire harness, but transferred old one to new ice maker (easy) and, "voila" some ice in 24 hours -- much ice since then. I am a 68 year old woman and it was "sort of fun" doing this job.
Parts Used:
Replacement Ice Maker
  • Pat from Dallas, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
77 of 91 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker made a clicking noise then quit making ice
Motor from Part Select was 185W instead of 260W that came out of unit. After a bit of searching online, I found out the 260W had been obsoleted for lack of torque when harvesting ice.

Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.
Parts Used:
Icemaker Control Assembly
  • Ryan from Layton, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
77 of 96 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice in ice trey
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace holding pins and start the process of putting back together the opposite way you took it apart.
Parts Used:
Cycling thermostat
  • Wayne from Leesburg, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
78 of 100 people found this instruction helpful.