green lite out
had to take side cover off, then 2 screws on cover holding t.stat and orange and green lite in place. Replaced lite but couldn't get one of the screws back on in such a tight place and doing it blindly. Had to fix adheasive instead of one of the screws.
Parts Used:
LIGHT - GREEN
  • Matthew from Beltsville, MD
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Themostat would not cycle
Put unit up on a work bench removed compressor access door with a philips screw driver then removed two screws holding thermostat in unit. Then removed knob from thermostat removed the wire connections , used a nut driver to remove nut from around control adjustment stem. Then removed sensor line from its tube..Reversed the fore mentioned process pluged that puppy in and we had popcicles again. The whole thing took about a half hour.
Parts Used:
THERMOSTAT
  • Russell Wyman from Carriere, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!