refrigerator was not cooling but the freezer worked fine.
My husband put on the defrost timer. At first I thought the part was not going to fix the problem. After about 5 hours my refrigerator was still warm. I went to work and when I got home that evening my refrigerator was cooling and down to 28 degrees. So if you replace this part wait at least 12-24 hours. Give it time to stablize. My husband says it has to go through its cycle. It works on a 24 hour timer. My refrigerator is working fine and this has saved me alot of money. My husband says, once you put on the timer you may have to use a flat screwdriver and turn the small dial clockwise one click to start it. He removed the kick grill and replaced the part. Dont forget to shut breaker off to replace this part. Turn power back on and start the timer. We are so happy that we now have a working refrigerator.
Parts Used:
Defrost Timer - 120V 60Hz
  • Wanda from Cabins, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
86 of 100 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
display showed dE
popped off front grille, removed 2 screws for bracket, then had to remove one screw for timer. unplugged old timer, reversed procedure, all works.
Parts Used:
Defrost Timer - 120V 60Hz
  • Nancy from Hamburg, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
74 of 116 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
not making ice
when the ice maker runs through its cycle, you should be able to hear the solinoid valve open, letting water into the ice maker. this was not happening for me. you can dissconnect the plug on the valve and put the two probes from a multimeter in the plug and set for AC volts. when the ice maker runs its cycle, at the end you should see the meter jump as power is applied to the valve then turns off. this means you do have power to the valve so the valve is defective. turn off water supply to the valve, disconnect the water supply tube to the valve, remove the screw holding the valve, disconnect supply tube to icemaker then hook up supply tube to bottom of valve, screw braket back to refrig, install suppy back to valve, turn water back on and check for leaks and your ice maker should be working properly again.
these guys were really fast on delivery too!
Parts Used:
Single Outlet Valve Kit
  • thomas from richmond, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
33 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water appearing under refrigerator
Unplugged the refrigerator and turned off the water to the ice maker valve. Removed the water line at both ends (small crescent wrench). Removed the cover from the water valve area (two Phillips head screws). Removed the valve (two screws - small nut driver) and pulled off the two electrical connections.

Installed the new valve with the reverse procedure though the holding screws didn't line up with the existing holes in the refrigerator metal frame. I let it go with one screw holding ... didn't have a drill with me to make a second screw hole.

Replaced the old water line (from the wall to the valve) with a steel-reinforced hose.

Cut the female metal connector from the old water line up to the freezer and it fit nicely into the push-in outlet from the new valve. Turned everything back on and waited for the ice maker to cycle.
To my dismay, the leak had been coming from the plastic line that goes from the valve up to the ice maker. It had split, spraying water. Replaced that and everything works fine.

Lesson learned: Don't assume water near the icemaker valve actually is from the valve or its water connections. Watch the whole system cycle a couple of times to see what's really happening. Glad to have a new valve but the basic problem was the icemaker tubing.
Parts Used:
Single Outlet Valve Kit
  • Larry from Dallas, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Wrench set
31 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Panel hot to touch between freezer & refrigerator. Motor hot, fan not rotating.
Unplugged refrigerator, removed three screws to take out part, disconnected the wires and removed bad unit. Removed fan blade from old unit and attached to the new unit. Attached wires, placed the new motor back in. Plugged it back in, within 20 minutes panel between freezer and refrigerator was cool to touch.
Parts Used:
Condenser Fan Motor - 115V
  • Kimberly from Grandy, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
32 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
during defrost cycle water dripped into freezer and froze all over ice bin
First I removed the ice maker. Second I removed the back panel and overhead panel above ice maker. Third I pulled down the drip trough it had a styrofoam base under it. The trough heater had to be unplugged to remove the trough as well as the drain hose. Forth I seperated the styrofoam from the trough and peeled off the old heater which had burn marks on the foil. Fifth I applied the new heater plugged it in and attached the drain hose to the trough. Last I reassembled the unit. Refridgerator works great now and it only cost $45.00 for the heater. The GE repair service quoted over $950.00 and did not list the trough heater as the problem so I would be spending more and would have required several repair visits.
Parts Used:
De-Icing Kit
  • Bob from Aurora, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
26 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator would not defrost
Look were timer was located, in my refigerator is next to the dial to ajust the temperature. used a screwdriver to get panel off. replaced timer then used a straight screwdriver to advance timer to turn on compessor . monitor temperature . checked out.
Parts Used:
Defrost Timer - 120V 60Hz
  • Donald from worthington, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water valve didn't shut off completly
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
Parts Used:
Single Outlet Valve Kit
  • Raymond from Concord Twp., OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set, Wrench (Adjustable)
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor overheating - Fridge not Cooling
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Parts Used:
Condenser Fan Motor - 115V
  • CHRIS from LAGUNA NIGUEL, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor rattled loudly
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Robert from Kingwood, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker did not work
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
Parts Used:
Single Outlet Valve Kit
  • Kenneth from Bellevue, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Parts Used:
Condenser Fan Motor - 115V
  • PERRY from VANDERBILT, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Wrench set
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
botton half of refrigerator not cooling
easy as 1.2.3 remove and replace before even thinking. just to let you know i also do this for a living but it is one of the most difficult thing when you have to stop and fix your own
Parts Used:
Defrost Timer - 120V 60Hz
  • HANCEL from ELMONT, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
25 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Parts Used:
Condenser Fan Motor - 115V
  • JEFF from HAMPTON, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking Valve on Ice Maker
I ordered the part and it got here very quickly. Being a novice home repair person, it took me awhile to get the courage to start. It was practically uneventful, but it did take some time to figure it out exactly. I did have to bend the piece some, which is always a little nerve wracking. However, the part is working beautifully and I feel good about myself.
Parts Used:
Single Outlet Valve Kit
  • Linda from Montgomery, AL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!