Models > ASM18DAS1

ASM18DAS1 General Electric Air Conditioner - Overview

Sections of the ASM18DAS1

[Viewing 2 of 2]
Keep searches simple, eg. "belt" or "pump".
Condenser Fan Blade – Part Number: WJ73X10115
Condenser Fan Blade
PartSelect #: PS783746
Manufacturer #: WJ73X10115
$138.89
  Special Order
Remote Control – Part Number: WJ26X10022
Remote Control
PartSelect #: PS275759
Manufacturer #: WJ26X10022
This remote control is used for an air conditioner.
  No Longer Available
NUT-WASHER – Part Number: WJ01X10119
NUT-WASHER
PartSelect #: PS274173
Manufacturer #: WJ01X10119
$7.60
  Special Order
PANEL PCB – Part Number: WJ26X10021
PANEL PCB
PartSelect #: PS275758
Manufacturer #: WJ26X10021
$130.54
  Special Order
CAPACITOR – Part Number: WJ20X10037
CAPACITOR
PartSelect #: PS275146
Manufacturer #: WJ20X10037
$105.51
  Special Order
INLAY CONTROL – Part Number: WJ26X10018
INLAY CONTROL
PartSelect #: PS275755
Manufacturer #: WJ26X10018
  No Longer Available
MAIN PCB – Part Number: WJ26X10020
MAIN PCB
PartSelect #: PS275757
Manufacturer #: WJ26X10020
$173.01
  Special Order
THERMISTOR – Part Number: WJ27X10031
THERMISTOR
PartSelect #: PS275935
Manufacturer #: WJ27X10031
$35.11
  Special Order
GRILL FRAME – Part Number: WJ71X10141
GRILL FRAME
PartSelect #: PS277973
Manufacturer #: WJ71X10141
$100.61
  Special Order
LOUVER MOTOR – Part Number: WJ94X10071
LOUVER MOTOR
PartSelect #: PS280058
Manufacturer #: WJ94X10071
$86.78
  Special Order
CONTROL COVER – Part Number: WJ26X10019
CONTROL COVER
PartSelect #: PS275756
Manufacturer #: WJ26X10019
$47.22
  Special Order
LOUVERS - ADJ – Part Number: WJ71X10140
LOUVERS - ADJ
PartSelect #: PS277972
Manufacturer #: WJ71X10140
$15.72
  Special Order

Questions And Answers for ASM18DAS1

Be the first to ask our experts a question about this model!

Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
compressor running - no running fan
Thia ia a common problem with all window units.
1) The fan runs but no cold air is coming out.
This indicates the compressor is not running.
2) The compressor is running and no air is coming out.
The fan motor is not running.
Both fan and compressor operate off the start-run capacitor, common to all window uunits.
This is located in the electrical control area of the air conditioner. note unplug the unit bdfore trying to locate this part. easily located, unplug the wires noting the color coded wires on which terminals, note make a diagram so you don't forget what wire goes on which terminal. Order and replace. If the unit is over 5 years old and you are able to afford to do so, I would replace the unit for a more efficent newer unit.
Parts Used:
CAPACITOR
  • william c from bay city, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan blade in our air conditioner broke
first my son removed the old blade then he replaced it with the new blade, and, we were back in business.
Parts Used:
Condenser Fan Blade
  • cynthia from Riverside, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
6 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!