Dryer would not start, no enterior light operation

  • Customer: Charles R. from Kingsland GA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 45 of 54 people found this instruction helpful
I down loaded the dryer schematic and itentified items that would potentially cause the observed symptoms. Initially, I replaced the thermal fuse. After the symptoms returned after two loads, suspected the hi limit thermostat not regulating the heater element temperature. I located the thermostat using the illustrated parts list on your website and replaced the thermal fuse (second time) and the thermostats using a nut driver. The Blond hasn't announced a dryer stoppage since the repair, so I'm pronouncing the repair a success. Thank you for making the drawings and schematics available.

Dryer would not run

  • Customer: Ron from Rutherfordton NC
  • Difficulty: Easy
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 42 of 46 people found this instruction helpful
Unplugged unit, lifted the top cover, removed heater element screw, lifted out element, lifted out thermal fuse bracket. Removed wires from thermal fuse, confirmed was open curcuit at room temperature. Attached wires to thermal fuse, inserted fuse into bracket, slid bracket onto clip on side of box that housed the heater element, reinstalled heater elememt, inserted long screw into heater element hole and tightened snugly. Extra to ensure proper air flow: Then removed wires from door switch on fron panel (labeled them), removed 2 screws at top of from panel, tilted and lifted front panel off, removed blower cover, cleaned all duct work from blower to exit of unit, sealed plastic duct that was attached to front panel. It had loose gaskets that allowed air to be drawn in from the sides and not through the duct thus bypassing the drum and heater element. Reattached blower cover, lowered and tilted front cover into place, reattached top 2 corner screws, reattached switch wires, lowered top. Plugged in and tested.
Note the Partselect sales person told me that the LA-1053 kit contained 3 items, however, it only came with the fuse, not the thermostats. Foutunately, only my fuse was shot.

High noise when switched on. Broken blower wheel.

  • Customer: Alexander from Green Valley AZ
  • Difficulty: Easy
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers, Socket set
  • 42 of 47 people found this instruction helpful
Lift top off. Removed front door. Removed blower wheel cover. Replaced blower wheel. Cleaned and put back togther. Needed circlip pliers to remove circlip retaining blower wheel.

Brooken lint filter and door seal

  • Customer: Tonja from Green Bay WI
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 69 of 132 people found this instruction helpful
It was easy - I had my 12yr old daughter do it. The old door seal was completely removed, then you placed the new seal in the apropriate knoches that are on the door of the dryer. The lint filter just had to be placed in the vent. - Done.

GAS FLAME WOULD DROP OUT

  • Customer: FRED from BRIELLE NJ
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 43 of 57 people found this instruction helpful
first it was a process of alimination to find out why it was dropping out. after the problem was found it was just a matter of replacing the holding coil on the gas valve.
THANK YOU
FRED KENNEY SR

It wouldn't start

  • Customer: Amaury from Wake Forest NC
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 66 of 128 people found this instruction helpful
First I removed the two screws that hold the element in place. I then pulled the element completely out and disconnected the two wires.

From there it was just a matter of installing the new part.

Anybody could do it

Dryer will not start

  • Customer: paul from PEACHTREE CITY GA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Pliers, Screw drivers, Socket set
  • 33 of 41 people found this instruction helpful
I replaced the timer asembly, still did not start.
I REPLACED THE HEATER SENSORS, TWO OF THEM,THAT DID
THE JOB.I suggest to check both heater sensors first, one I missed at the beginning is on the right side of the heating coil, kind of hidden.I believe that one was the problem.
I could have saved myself some money if I had found and checked that sensor first.

Gas burner would not ignite

  • Customer: Jack from Conroe TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Wrench set
  • 27 of 30 people found this instruction helpful
(I knew the gas coils were bad, since the gas ignitor would glow brightly as the burner attempted to ignite. So I knew everything except the gas valve was operating normally.)

Unplug the electrical cord to the dryer. Remove the front access panel. Remove the retainer clip for the gas coils (2 screws). Remove the coils and unplug the electrical connections. Connect the new coils to their respective electricl connections. Slide the nes coils back onto their respective posts on the gas valve. Replace the retainer clip, and 2 screws to hold it in place. (I then plugged the dryer back into the wall outlet to visually check the burner operation) Everything worked fine so I then replaced the front panel.

Dryer belt snapped

  • Customer: J. from Oakdale NY
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 28 of 33 people found this instruction helpful
There are a total of six screws that have to be removed to do this job.
Take the lint tray out and remove the first two screws.
Secondly, remove the lower panel in the front of the dryer. You do this by inserting a screwdriver at the top portion and pry it off. Next, loosen the two screws under the top panel in the front of the dryer.
Now take your screwdriver and pry up the top lid of the dryer. The last two screws are in the inside of the front panel. They hold together the front and side panels. Remove them and be sure you have a support for under the dryer drum. (once you remove the front panel, the drum no longer has a way to stay suspended)
(Make sure you disconnect the wires attached to the front door, making note of which wire goes where.)
At this point, You can follow the easy instructions that come with your new belt.
If you have a little mechanical aptitude, this is a very easy project.

Dryer would start and heat, but after 1st cycle the burner would not fire and a buzzing sound was coming from the gas valve solenoid area. Igniter and other functions worked fine.

  • Customer: David from Bedford IN
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Wrench(Adjustable)
  • 25 of 27 people found this instruction helpful
Removed front of dryer, unplugged each coil to determine where buzzing was coming from.....determined it was the boosting coil....ordered part and replaced. Dryer works great....we think it had be going bad over time because drying times have noticeable decreased.

Drum stopped turning, fan continued to blow

  • Customer: Richard from Davie FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 24 of 25 people found this instruction helpful
Disconnected supply. Lifted top (hinges on rear). removed two 1/4 hex head screws retaining front panel. Disconnected door switch wires. Removed front panel, lifting off from bottom tabs. Lifted out drum and discarded broken belt. Spent 30 minutes+ cleaning interior, drum skid area, dryer exit tube, motor pulley, belt tensioner, etc, etc. Checked wiring harness for possible damage (no damage found). Repositioned drum skid pads, which had become dislodged from their intended position. Reinstalled the drum with new belt, ensuring both belt & tensioner were correctly positioned, and drum rollers and felt seals were also correctly positioned. Reinstalled front panel, tightening the two 1/4 hex head retaining screws. Reconnected power. Checked functionality. Closed top cover.

Dryer would run but never shut off

  • Customer: Raymond from Newark TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 28 of 37 people found this instruction helpful
I removed the cover plate than pulled off the knob to gain access to the two screws holding the timer assy. in..once they were removed i removed the wires one by one and installed them on the new timer.then reinstalled it put the cover on and was done

The dryer would start to heat then the heat would stop

  • Customer: Theodore from Riverside CA
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers, Wrench set
  • 26 of 17 people found this instruction helpful
I changed out the cycling thermostat and the high limit thermostat. Mainly because that was what my research indicated was the problem. I then found some more information online that indicated the gas solenoid valves were bad. I ordered them from you and replaced them. The problem was fixed.

In order to replace the valves you need to remove the top panel. Two screws at the top of the front door assembly hold it on. Remove the screws, lift up on the front panel door assembly and move it to the side. The drum will rest in place. In the lower left corner, under the drum, you will see the solenoids. Two screws attach a plate that holds down the solenoids. Take the hold down plate off, disconnect the control wires attached to the solenoids and lift out the solenoid/control valves. To assemble everything, work backwards to the start. Good Luck

Dryer would not heat up.

  • Customer: Roger from Bonners Ferry ID
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 22 of 24 people found this instruction helpful
I unplugged the dryer,removed the two small screws on the front of the dryer and pulled the bottom forward. The two wires connected to the door do not have to be removed. With an electrical tester using the Ohm setting I tested the Radiant sensor and the Gas Valve coils. The two terminal coil was DOA. The dryer can be operated with the front open as long as the door wires are connected. Symptons: The igniter would heat up and not release gas. My repair was successfull due to this awesome website and the super fast shipping service. AAAA++++

Intermittent or no gas ignition, HSI ignightor working

  • Customer: Steven from Sauk Village IL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 23 of 27 people found this instruction helpful
Removed front of gas dryer and cleaned all lint out. Checked HSI, and cleaned flame sensor. Split (3 terminal) gas coil terminals were intermittent. Read about 700 ohms across outer two terminals, but center terminal to either outer terminal was open (Infiniti on meter) 2 terminal coil measured about 550 ohms. 3 terminal coil should read about 700 ohms across outer terminals, and about 1.5K ohms center to outer terminals. Unscrewed index cover plate and replaced coil, 2 terminal coil was okay. Reassembled and finished 12 loads of laundry no problems at all.