Icemaker producing few or no cubes and often leaving "kling-ons" on ice tray
Interior surface of ice tray felt rough & flaky (coating deteriorated) so cubes would not release.
Unplug appliance.
Remove timer cover by hand pressure @ edge.
Remove single attachment screw & bracket at lower front of icemaker.
Disconnect wiring harness from socket @ rear of compartment.
Tricky part was determining what type of connection held the other two attachment points along the long edge of the icemaker. I did not have repair manual or useful drawing but looked @ PartsDirect pic of side brackets & used a small mirror to confirm that mine were also some sort of "snap in" attachment.
Remove icemaker unit by pushing upward and outward on the unit. I takes a good bit of pressure and will pop loose, but be careful not to break attachment bracket from freezer wall.
Scavenge shut off bar and wiring harness from old icemaker once you have it out & attach to new one before installing it back in freezer.
Again, you might find a mirror useful to align those pesky snap-in brackets with the new unit.
Since you probably kept your freezer running while waiting for the part, the plastic snap-ins will be cold and brittle. I warmed them up first by applying a dampened cloth heated in the microwave to make them a little more pliable.
A good push of the new unit towards the snap-ins along with some upward force will get it stable.
Reattach the metal screw in bracket & connect the wiring harness to rear plug... and don't forget to plug the whole thing back in.
It will take awhile for the first batch of cubes dump as the timer may need to cycle completely around to get to the fill cycle... be patient.
Dump the first couple of batches of cubes just to make sure you're free of any residue.
Parts Used:
Replacement Ice Maker
  • Bernie from Diamond Bar, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
801 of 885 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My refrigerator stopped cooling and the freezer section stopped freezing
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
Parts Used:
Capacitor
  • garth from forest lake, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
394 of 474 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The compressor would not run.
I removed the screws in the lower back panel where the compressor is located. Then I unplugged the capacitor and plugged the new one in. I then checked to see if the compressor would start. It wouldn't so I replaced the overload relay with capacitor and that fixed the problem. The capacitor just plugs into the relay then plugs into the compressor. There are several screws but all in all it is easy.
Parts Used:
Compressor Start Device and Capacitor Run Capacitor
  • Gilbert from Clinton, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
325 of 371 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water overflowed ice maker turnning ice bucket into solid mass of ice
My ice maker has been shedding its non-stick coating for over a year. Within the last month of so, it started pouring water into the ice bucket below, turning it into a solid mass of ice. So I purchased a new ice maker assembly. I encountered two problems not mentioned in the 21 or so do-it-yourselfer repair stories that precede this one. First problem: one of the three screws that hold the ice maker to the refrigerator wall is hidden behind the large (black) end of the ice maker and is difficult to access. Before trying to replace the ice maker, make sure you have the physical dexterity to remove that screw. Second problem: it is not apparent how to remove the wire harness that plugs into the ice maker assembly. BEFORE you can remove the wire harness, you MUST remove the large white cap that covers the black end of the ice maker assembly and then push in a retaining tab to release the wire harness. If you don't do this, the wire harness will not release. Other than those two problems, it was relatively easy to remove three screws, unplug the wire harness, transfer three small, metal parts from the old ice maker to the new, plug in the new wire harness, mount the ice maker assembly so that the water tube is in the proper position, and then re-install the three screws. The ice maker works fine now. (P.S. I was told by an expert that the real problem might be a malfunctioning fill valve. I would have replaced the fill valve if replacing the ice maker assembly had not fixed the problem.)
Parts Used:
Replacement Ice Maker
  • Harry from Grand Ledge, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
269 of 364 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked & Snapped Center Crisper Rail
A very easy fix took all of five minutes
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • Ruth from Roxbury, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
226 of 245 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Sometimes the condenser fan would start causing the refrigerator to overheat.
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Parts Used:
Condenser Fan Motor Kit
  • Tom from Franklin, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
180 of 204 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator was not getting cold and the coils were not defrosting.
Start by removing the freezer door and inner baskets so you have some space. Next, take out the ice maker by removing the 3 screws that attach it to the side and unplug it from the harness. Then the cover for the thermistor and the fan vent should be popped off carefully leaving the back cover only. The back cover is held on by 4 screws, one in each corner. Remove all 4 screws and carefully loosen the back cover by pulling the top forward and laying it level to pull it out. Behind the cover are the coils and other components. If the coils are covered with ice they should be defrosted by using a blow dryer. Once the ice is clear, the thermostat is located towards the top left clamped onto a copper pipe that circles up and around. Carefully pull it off the pipe and cut the wires making sure you leave enough to reattach the new ones with a butt connector. Strip about 1/4 inch of insulation off the wires and crimp both ends into the butt connector making sure they are tight. Heat shrink is highly recommended. Clamp the new thermostat to the copper pipe where the old one used to be and your almost done. Replace the back cover the opposite of the way it was pulled out by putting it in flat with the bottom part in front. Once it is all the way to where it needs to be, push the top upwards while sliding the bottom downwards, then push it in flat against the back. It can be bent slightly if needed. Put the screws back in that hold it on and replace the plastic covers. Then reinstall the ice maker being sure the hose for the water is correctly positioned so that the water goes into the ice maker. Turn it back on and put the baskets and door back on and you're done.
Parts Used:
Defrost Thermostat
  • Cheryl K from Pinellas Park, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
149 of 167 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator sat in storage in sub zero weather, water in Dual Water Inlet Valve froze, cracking valve.
This is the 2nd time I have used PartSelect, and this experience was as pleasant as the 1st. The exploded-view diagrams make parts identification very easy; and the photo of the actual part is such a great idea, it allows you to verify what you need. I also got my part (cross country, in 3 days)

Repair Procedure: Shut off water supply. It may be easier to work if you disconnect the water supply tube, but it is not required. On the backside of the refrigerator, remove the bottom, black plastic protection panel. You will need a nut driver or battery-powered screw driver with a 3/8" socket tip on it. Next, remove the black metal panel that holds the water inlet valve in place. Remove screws with a nut driver. 1st remove the two flat-pin power connectors. (They are different sizes and color-coded, so there is no room for making a re-hookup mistake). Then proceed to remove the hoses. The hoses are pressure-lock tubing, so push the plastic disk in or down where the tube goes into the main body of the valve. Do this for all three hoses (tubes). Switch water valves and reverse the procedure. **Be certain that the tubes are pushed back in as far as they can go; if you do not re-seat the tubes, the pressure from the water going back in the valve, will blow the tubes right out the valve (ask me how I know this!). Once reassembled, turn the water back on slowly. Make sure you turn the water supply valve all the way open, it seats itself internally when you do and is less prone to drip leaks. That's it! (As a former kitchen remodeler, I find this a great DIY project).
Parts Used:
Dual Water Inlet Valve
  • JIM from Greeley, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
109 of 119 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaking from bottom of refrigerator onto floor
The video on website is very good and explains everything in detail. Just follow the directions. This is EASY!!!!
Parts Used:
P-Trap Drain Tube Kit
  • Jack from DINUBA, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
102 of 110 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
Parts Used:
Water Fill Cup and Bearing
  • David from Chester, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
107 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Parts Used:
Refrigerator Door Switch
  • Clint from Rayville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
118 of 192 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
not making ice
Installed new ice maker. It was easy - loosen two screws and unplug old wire harness. Put new unit in place. Did not realize new unit would not come with wire harness, but transferred old one to new ice maker (easy) and, "voila" some ice in 24 hours -- much ice since then. I am a 68 year old woman and it was "sort of fun" doing this job.
Parts Used:
Replacement Ice Maker
  • Pat from Dallas, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
77 of 91 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frig not cold at all,Freezer was all defrosted
Well the frist thing I did was get out the all the paper work and look under trouble shooting.This frig has a list of codes to try to help narrow down what parts might be bad.Well at frist it seemed it was a Defrost Thermastat?Well thanks to PartSelect it showed me right where it was and step by step how to remove and replace it.It took me over 2Hr's,after that I let the frig run all night and the next morning(yep warm frig)not the part I needed,well now Im mad,the local part store said you need a 3in1 jump starter easy to in stall at $50.Can'nt bring parts back no way weather thier opened or not.So get home and can'nt see how this jumper is going to wire up to my compresser?So on to the Web site to get some info,find out that this part gets a thumb's down,it puts out more volt's then needed and kills your compresser the reviews where very help full.So back to PartSelect to see more info,then I spoted the Overload/Relay and went to the back of my Frig and this part just plugs right into the compresser,I pulled it of with pliers and Bingo a burn spot melted right through the Overload/Relay.Ordered the right part the same as the old one.Put the part in and Bam,compresser fired right up.If I only did alittle more home work I could off saved alot of head ach and money.Thanks PartSelect I'll alway's click on to your web site for future parts and advise.
Parts Used:
Compressor Start Device and Capacitor
  • Denise from SOUTHINGTON, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
64 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Build-up in freezer
We have a bottom freezer refridgerator that kept having ice build-up in the freezer. We thought it was being caused by people (kids) not fully closing the freezer door. The ice build-up was really thick especially behind the rear cover. i defrosted the freezer about 3 times and it kept happening. We replace the timer (PS2065577) and have not had a problem since. The timer is actually in the refridgerator compartment , but controls the defrost cycle in the freezer.
Parts Used:
Defrost Timer - 120V 60Hz
  • Dave from San Diego, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
67 of 84 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cold but freezer was cold
removed ice maker and wire shelf. removed back panel screws and tilted forward. removed 2 screws holding motor bracket. swapped fan blade and reassembled
Parts Used:
Freezer Evaporator Fan Motor - 115V 60Hz
  • jarrett from PALM DESERT, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
65 of 79 people found this instruction helpful.