everything worked except it wouldnt cook
tested all 3 of the door switche for continuity, the top switch was faulty, replaced it,for approx $4.00 and saved a $350 dollar microwave.
Parts Used:
Switch,Micro
  • Joseph from N VERSAILLES, PA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
11 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Magnitron failed
Over the stove microwave installed in top cabinet row.
1. Unplug device.
2. Two people to remove from wall/cabinet (remove two, large, top mounting screws and rotate entire microwave down and off the wall mount). Should be some wood spacers between top of device and bottom of cabinet.
3. Remove screws from sheet metal cover.
4. Remove one screw holding blowers in place and rotate out of the way, in order to gain access to 2 of 5 screws that hold the magnetron in place.
5. Unplug magnetron and remove the 5 screws.
6. Drop in new magnetron and re-assemble microwave in reverse order (steps 5-3).
7. Two people restore micro to wall/cabinet. Replace wood spacers, re-install two, large mounting screws (finger-tight). Test device. Secure the two large screws.
Parts Used:
Magnetron
  • Joseph from WILTON, NH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The over the stove microwave door would not close.
I unplugged the microwave. I did watch a YouTube video to see how the plastic frame around the door could be removed. I used a putty knife to pry it off. The spring was still in good shape, so I hooked it up to the new latch/locker part and onto the microwave. This was just a little time consuming because I was trying to be careful so I wouldn't break anything on the new part. The plastic frame clicked right back on. I plugged the microwave in and it worked right away. If I can do it, you can do it. Sure beat buying a new microwave. Great experience.
Parts Used:
Locker
  • Christine from LUXEMBURG, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door switch was burnt out
Removed outer cover

removed lower door switch

installed new switch

Wa La!
Parts Used:
Switch,Micro
  • Edward from ORCHARD PARK, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not heat and made a buzzing or popping sound
Unplug the microwave. Remove the Philips head and safety Torx head screws along the bottom of the sides and rear of the microwave which hold the black cover on. Lift the cover up at the rear and slide it backwards to disengage the tabs on the front top. Remove the cover. Discharge the capacitor by shorting the terminals to each other and then ground. Do this with a well insulated object and be aware there may be a pop when you do this. Keep hands, etc. on the insulated part of the object (screwdriver handle, etc). There's a lot of stored energy in that capacitor. I'd advise first checking the diode to make sure its not bad. Replace it if it is. The Magnatron is held in with a couple of screws on the top and sides. Unplug the connector and remove the screws. Remove the Magnatron. Installation is the reverse of removal.
Parts Used:
Magnetron
  • Thomas from NEWARK, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave door would not shut completely and would not activate switches
After checking all three switches for continuity I determined that the plastic door lever had warped or gone out of wack. After shutting off power at the breaker box I removed the door, the inside trim piece around the inside of the glass. Removed the black two prong door lever, reattached the new door lever and then reinstalled the trim piece and all screws. Works fine now. Easy fix just make sure your switches are all ok then replace the door lever.
Parts Used:
Locker
  • Timothy from DELAND, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door locker snapped off
Unplugged the microwave. I opened the door. I used a butter knife to pop the bezel off the inside of the door. I pushed the locker up and to the left and used the butter knife to pry it loose. Disconnected the locker from the spring, and reversed for the installation.
Parts Used:
Locker
  • Dave from FOREST, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wanted to see the instructions before I install it.
Wanted to see the instructions before I install it.
Parts Used:
Damper
  • Rene from MORENO VALLEY, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Latch broken... Spring off
You Tube
Parts Used:
Locker
  • Toni bc from PORT ORANGE, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacement of Magnetron
I UNPLUGGED the microwave and removed the cover, using a phillips and a Torx screwdriver for the machine screws. I set these screws aside, so as not to confuse them with the later encountered screws. I photographed the magnetron to assure proper placement of the 6 phillips machine screws involved in reassembly (marking the the locations on the old magnetron would do as well. I marked the old magnetron "old", to avoid later confusion. I removed the two screws holding the shields to the magnetron. I removed 3 of the 4 screws holding the magnetron to the microwave, leaving one of the top screws. I held the magnetron securely and removed the last screw, pulling out a the part of the magnetron that penetrated the microwave. I installed the new magnetron in reverse order. One problem I encountered was locating one of the six screws, which had been pulled into the old magnetron by magnetism.
Parts Used:
Magnetron
  • Benjamin from Anchorage, AK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Latch spring keeper broke
Removed door from microwave and then popped the inside widow trim ring off. Removed 4 screws from the window bracket, replaced the latch with a new part and then assembled.
Parts Used:
Locker
  • Gregg J. from WEST CHESTER, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bulb replacement
very simple
Parts Used:
Light Bulb - 120V 30W
  • Marianne from CHURCH HILL, MD
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
8 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave operated but did not heat
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Parts Used:
Fuse,Time Delay
  • Donald from Oak Ridge, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
1 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light bulb burned out
I unscrewed the light cover, removed the burned out light bulb and replaced it with one I ordered on Partselect.com. It was very easy.
Parts Used:
Light Bulb - 120V 30W
  • Craig from Burke, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
no heat
unplug the unit then pull down , lot of screws are on top. open the cover . you could see the parts that need to replace on the right hand side (heavy side). disconnect wires then test the parts that need to replace by a tester to make sure that it's really broke .then unscrew part and replace .
Parts Used:
Magnetron
  • Nelia from Streamwood, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?