Models > 72163299303 > Instructions

72163299303 Kenmore Microwave - Instructions

All Instructions for the 72163299303
1 - 15 of 25
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broken door micro switch. (unit does not start heating)
Unplug the unit before servicing. Need phillips screwdriver. Open door. Use step ladder to access and remove 2 small screws from top of the room air diffuser at top of unit. Slide diffuser slightly to the left to align the diffuser's plastic tab on the left side to rotate toward you. (The wires for the front control panel are at the far left side of this difuser, but difuser is slotted for easy removal). Once the difuser is removed you will see 1 screw at the top that secures the pannel cover on the left side of the unit. Remove screw and slide this panel slightly up and out. This exposes the plastic frame that holds the upper and lower door switches. To locate the door switches and observe how they work, close and open the door and watch the door (bayonets) open and close the micro switches. Do the (red) buttons on top of the switches move up and down when the door bayonets push and release? If the buttons do not "pop" up when opened the switch is defective. The switch frame is secured with 2 screws. Remove screws and rotate the unit out for easy access to the micro switch(s). The internal (spring?) on my unit that is suposed to allow the red (visible) button on top of the switch to "pop" up when the door is opened was broken. Carefully pry the switch outward while being careful to lift the plastic holder-piece that holds the switch in place. Be careful, there is a small pin on the frame, so rotate the switch OUT toward you while lifting (carefully) the plastic holder-piece (you will see it on top of the switch). You can use an ohm meter to test the continuity of the switches. But if the buttons don't "pop" they are defective. Replace switch and reassemble.
Parts Used:
Micro Switch
  • JAMES from BILLINGS, MT
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
30 of 49 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door sensor switch went bad. Microwave would not operate.
Watched a couple of repair videos on Youtube by searching for the model number. Found out what to do in order not to get shocked by the powerful capacitor.
Ordered the two switches (To be sure, I could have ordered a third switch as suggested in the videos.)
Bought a tamper-proof star bit to get the cover off. Followed the directions to replace the switches. - I broke the harness and had to use some super glue, but it's all good. I should have removed the harness instead of trying to get a switch out while it was still in place.
It's all back together, and the wife is happy!!
Parts Used:
Micro Switch
  • Randall from ARCADIA, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
everything worked except it wouldnt cook
tested all 3 of the door switche for continuity, the top switch was faulty, replaced it,for approx $4.00 and saved a $350 dollar microwave.
Parts Used:
Switch,Micro
  • Joseph from N VERSAILLES, PA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
11 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Magnitron failed
Over the stove microwave installed in top cabinet row.
1. Unplug device.
2. Two people to remove from wall/cabinet (remove two, large, top mounting screws and rotate entire microwave down and off the wall mount). Should be some wood spacers between top of device and bottom of cabinet.
3. Remove screws from sheet metal cover.
4. Remove one screw holding blowers in place and rotate out of the way, in order to gain access to 2 of 5 screws that hold the magnetron in place.
5. Unplug magnetron and remove the 5 screws.
6. Drop in new magnetron and re-assemble microwave in reverse order (steps 5-3).
7. Two people restore micro to wall/cabinet. Replace wood spacers, re-install two, large mounting screws (finger-tight). Test device. Secure the two large screws.
Parts Used:
Magnetron
  • Joseph from WILTON, NH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The over the stove microwave door would not close.
I unplugged the microwave. I did watch a YouTube video to see how the plastic frame around the door could be removed. I used a putty knife to pry it off. The spring was still in good shape, so I hooked it up to the new latch/locker part and onto the microwave. This was just a little time consuming because I was trying to be careful so I wouldn't break anything on the new part. The plastic frame clicked right back on. I plugged the microwave in and it worked right away. If I can do it, you can do it. Sure beat buying a new microwave. Great experience.
Parts Used:
Locker
  • Christine from LUXEMBURG, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door switch was burnt out
Removed outer cover

removed lower door switch

installed new switch

Wa La!
Parts Used:
Switch,Micro
  • Edward from ORCHARD PARK, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the turn table no turn and no heat the food. but the bottom oven worked
well I unplugged the microwave one day prior to working on it. shock precaution smart way to do this job. very easy pullout the screws behind the unit pull off the outer casing. minor screws inside the unit you have to remove a couple things out of the way. unplug the magnetron and remove first gives you more room to work on the side panel to replace the micro switches. I only replaced one the bottom micro switch. only one bad, but since I was in there I clean the bulb and changed the magnetron any ways. I read other reviews and made my choice to do so. it works perfectly now. Thanks PartSelect for having parts.
Parts Used:
Magnetron Micro Switch
  • mark from SANBORN, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven would not start when closing door.
Removed some cosmetic panels. Removed the assembly with micro switches. Examined the faulty switch by checking the clicking action of switch. Two others were ok by this method. Replaced the switch with new one. Works fine so far. Thanks to web site and YouTube videos.
Parts Used:
Micro Switch
  • Raymond from DEPEW, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not heat and made a buzzing or popping sound
Unplug the microwave. Remove the Philips head and safety Torx head screws along the bottom of the sides and rear of the microwave which hold the black cover on. Lift the cover up at the rear and slide it backwards to disengage the tabs on the front top. Remove the cover. Discharge the capacitor by shorting the terminals to each other and then ground. Do this with a well insulated object and be aware there may be a pop when you do this. Keep hands, etc. on the insulated part of the object (screwdriver handle, etc). There's a lot of stored energy in that capacitor. I'd advise first checking the diode to make sure its not bad. Replace it if it is. The Magnatron is held in with a couple of screws on the top and sides. Unplug the connector and remove the screws. Remove the Magnatron. Installation is the reverse of removal.
Parts Used:
Magnetron
  • Thomas from NEWARK, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable Assembly broken or missing
Open the front door of the microwave oven unit. Lift out the round glass food tray. Remove the Turntable Assembly and set it asside. Position the REPLACEMENT Turntable Assembly orienting the centering socket to the drive home in the floor of the oven cavity. Gently tap the assembly assuring it mates with the drive mechanism below. Replace the food tray centering it on the Turntable Assembly. Gently move the food tray from side to side assuring that it moves correctly. Close the oven door. Follow instructions that came with the unit for set-up instructions. Done..
Parts Used:
Turntable Assembly
  • Robert from JUNCTION CITY, KS
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave door would not shut completely and would not activate switches
After checking all three switches for continuity I determined that the plastic door lever had warped or gone out of wack. After shutting off power at the breaker box I removed the door, the inside trim piece around the inside of the glass. Removed the black two prong door lever, reattached the new door lever and then reinstalled the trim piece and all screws. Works fine now. Easy fix just make sure your switches are all ok then replace the door lever.
Parts Used:
Locker
  • Timothy from DELAND, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door locker snapped off
Unplugged the microwave. I opened the door. I used a butter knife to pop the bezel off the inside of the door. I pushed the locker up and to the left and used the butter knife to pry it loose. Disconnected the locker from the spring, and reversed for the installation.
Parts Used:
Locker
  • Dave from FOREST, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Items were not getting heated up in the microwave,
I went to LG website enter model number and was given a list of parts that need to be replaced with a percentage of which part fails the most. I order micro switch PS3522738 which arrived and PS3529293 was backordered. I installed the one that arrived. The microwave worked briefly. I reordered and waited for both switches to arrive and installed both. The microwave still doesn't work.
Parts Used:
Micro Switch
  • Kenneth from CRYSTAL LAKE, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Latch broken... Spring off
You Tube
Parts Used:
Locker
  • Toni bc from PORT ORANGE, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
blew fuse
tested cap. with ohm meter which showed a short. A new HV cap., a fuse and it is working fine again.
Parts Used:
Capacitor,High Voltage
  • larry from LUCERNE, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 72163299303