Replacing the bulb in the freezer side

  • Customer: Yafa (and David) from Bothell, WA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 5 of 7 people found this instruction helpful
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.

Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.

Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser

  • Customer: Kenneth from Newton Grove, NC
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 5 of 7 people found this instruction helpful
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.

Chaged out Door Light Switch

  • Customer: Scott from Kansas City, MO
  • Difficulty: Really Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 5 of 8 people found this instruction helpful
By sliding athin screwdriver blade down the side of the old switch the expasion prong that hold the switch in place was compressed enough to allow the switch to come out easlily. Plugged in new swithc and snapped in place. Plugged the refrigerator back in and light has worked great sense!

Auger not dispensing ice, motor working properly

  • Customer: Michael from Madison, AL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 5 of 8 people found this instruction helpful
Firts checked the parts received werer correct for the repair and the correct part numbers ordered. Then removed the ice bucket with the auger in bottom. Emptied ice from original bucket auger assembly. Checked out the removeal of the face cover for the bucket auger and removed it from clips that held it in place. Checked the specifications of the old ice bucket compaired to the new parts. Installed the aurger assembly into the new ice bucket and removed the two screws from the old unit to use in secure the auger assembly in the new bucket. The only tool needed was a 1/4 inch nut driver. Installed the face place on the new ice bucket auger assembly and tested the fit in the freezer. Ran test of the auger assembly without ice to ck for any misinstlled parts. Refilled the ice bucket with ice and tested with ice to complete the repair.

We broke the vegetable drawer. So every time we tried to open it, the drawer would fall out. It was upsetting because the frig was pretty new and we use the drawer a lot.

  • Customer: DYANN from FRISCO, TX
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 4 of 5 people found this instruction helpful
We pulled out the old drawer and set it on the counter to get to room temperature. My husband was afraid if we tried to pull off the white handle when it was cold the plastice might be too brittle and break. When it was room temp, we pulled off the handle and slippped it on the new drawer and slid it into the frig. It was great to have it working again and like new!

Power cord was cut

  • Customer: Frederick from Hanover, MA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 4 of 5 people found this instruction helpful
I removed the 5/16 inch hex head nuts holding the rear access panel where the power cord was connected. Once removed, I released the Molex plug and ground wire. I connected the new cord, screwed in the ground and installed the rear panel. Having the exact OEM part made the job quick and easy.

leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day

  • Customer: Linda from Johnson City, NY
  • Difficulty: Really Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 4 of 5 people found this instruction helpful
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self

Our refrigerator would lose its cool.

  • Customer: Toby from Barstow, CA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 4 of 5 people found this instruction helpful
I found that the evaperator coil was freezing up solid, not allowing air flow. Something was wrong in the defrost circuit. After troubleshooting, I found that the defrost timer was okay, as well as the fan. The only thing left was the temperature switch (thermostat). I found the part online for a reasonable price and ordered it. The part actually came the next day, I was amazed. I removed the old part by cutting the wires. Then I snapped in the new thermostat and crimped the wires back together (color-matched). It was that easy and I saved myself hundreds of dollars. Great service!

Water overflowing ice maker

  • Customer: James from Denver, NC
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 5 of 8 people found this instruction helpful
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.

Too much weight in the crisper and I cracked off ther part that slides into the drawer guides.

  • Customer: Ursula from Oconomowoc, WI
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 4 of 5 people found this instruction helpful
I simply needed to replace the drawer. Customer service Really Is Customer Service at this company! The young lady with whom I spoke on the phone was courteous, knowledgeable and efficient. She knew what I neeeded from my rather inept description. I was told the drawer would arrive in 10 to 12 days, but I actually received it in 3!!!!

Ice maker stopped working

  • Customer: Raymond from Panama City Beach, FL
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 3 of 3 people found this instruction helpful
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.

broken roller

  • Customer: John from Capac, MI
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 3 of 3 people found this instruction helpful
proped up frig, loosened screws, cut pin, installed rooler w/ new pin, rounded pin end, reistalled, lowered frig...everyone happy, thanks again partselect.

Ice maker stopped functioning

  • Customer: richard from colorado springs, CO
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 3 of 3 people found this instruction helpful
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.

Ice forming around ice chute

  • Customer: George from Tunnel Hill, GA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 3 of 3 people found this instruction helpful
I had to order three times before I got the right part. This was due to my rush to fix the problem and not studing the diagram carefully (black and white diagrams are not that clear). The repair was very simple. Just remove the rubber from the plastic door and slip on the new one.

old valve was cracked

  • Customer: Duston from Lawton, OK
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 3 of 3 people found this instruction helpful
remove the back plate, removed the screw holding the valve, removed electrical wires and water tubing. installed new valve. very simple. also i received the valve in one day. thank you