inconsistent compressor and condensor fan operation

  • Customer: Steve earney from Brooks GA
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 122 of 125 people found this instruction helpful
Compressor start relay would cycle several times before compressor would come on. Replaced start relay and defrost timer assy. Operated more consistently however not completely reliable. Ice would begin to melt. Noticed that if you would cycle the temperature control the compressor would start again and operate for several hours then not cycle again. Jumpered temp control and operation was continuous and reliable. Replaced cold control thermostat. Operation now normal. Suspect high resistance in switch caused start relay and timer contacts to arc. Small amount of carbon noticed under temp control...

Refigerator door was not closing all the way if not pushed shut.

  • Customer: Norbert from Sugar Land TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 113 of 116 people found this instruction helpful
Remove the top hinge cover. Removed the top hinge support. Lifted the door from the bottom support. Old door cams were worn completly flat. Replaced the lower door cam and closing cam use a little vasalene for lubricant on the cam surfaces. Placed the door back on the lower hinge support. Replaced the top hinge support. Door is closing great now.
Thanks for the quick part deliver.

Fridge was getting too warm, ice buildup on coils.

  • Customer: Cathy from Winter Park FL
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 78 of 86 people found this instruction helpful
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.

The compressor would shut down and not restart unless you tapped the temperature knob which i did for about 3 weeks before ordering this part

  • Customer: michael from clarksville TN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 58 of 62 people found this instruction helpful
Was pretty simple just take the knobs off pull off the face plate remove a few screws and drop the whole shelf down. then a few more screws down the side to the back of the fridge. Pull the sensor wire out of some styrofoam and pull off the plastic coating and slide it over the new one and install it in reverse order from taking it out. Works great now and i have ice everyday :)

Previous owners of the condo took the two drawers from the refrigerator

  • Customer: Betty from Orinda CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 43 of 52 people found this instruction helpful
No repair, just slid the drawers in their places.
Since you had a diagram of the refrigerator parts, ordering the parts was easy and I was confident that the parts were the correct ones.

Refrigerator Door quit closing on it's own......

  • Customer: T.w. from Batesville AR
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Socket set
  • 36 of 38 people found this instruction helpful
Door quit closing on it's own......

** Order the following from www.partselect.com

Lower Door Closing Cam -- Part Number: PS323495

Upper Door Closing Cam -- Part Number: PS327641




1. 1/4 drive socket and standard socket
2. On top of door .... remove black plastic bracket cover on top of hinge
3. Have someone hold the frige door in place
4. On top of door .... remove 3 screws that hold the hinge onto the frige..... at this time, door will be loose
5. Lift door up and off the bottom hinge.
6. sit door on the ground. Tilt door at an angle for access to the "cam"
7. On frige, at the bottom, use socket to remove one screw that holds the old "bottom" cam in place..... then replace with new one.
8. While door is tilted, use socket to remove one screw that holds the "top" cam in place.
9. You will need to gently pull this cam out.... shouldn't take too much effort though.
10. Replace with new cam.
11. put door back on hinge
12. At top of frige, reinstall 3 screws
13. Reinstall plastic cover.
14. Voila, you're done

Thanks PartSelect !

Refrigerator was not cooling properly.

  • Customer: Eddie from Gretna LA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 35 of 37 people found this instruction helpful
I removed both plastic knobs from assembly faceplate. Then I loosened the screws holding thermostat housing to upper cabinet of fridge. Following this step, I loosened the screws of the thermostat to remove it. Next was the removal of the plate and vent pieces holding the thermostat wire sleeve in place. After removal of thermostat from sleeve; all steps were reversed and unit was up and running normal (cooling) with no problems. "Ahh, it's nice to have cool again "

Lights inside refrigerator not working

  • Customer: Clint from Rayville MO
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 36 of 43 people found this instruction helpful
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.

REFRIGERATOR WASN'T COOLING,EVAPORATER COIL FREEZING UP

  • Customer: Robert from Doral FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 28 of 35 people found this instruction helpful
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment.
The bi-metal switch was right there in plain view. There are two colored wires that come out of the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good

Cooling would shut down and not restart until refrigterator was turn off and back on.

  • Customer: Michael from Oceanside CA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set
  • 23 of 23 people found this instruction helpful
First I removed the cover plate over the cover over the thermostat, by snapping it out. Then I removed the four screws holding the cover over the thermostat in place. Next I removed the screw, which held the cover over the thermostat sensor. I then removed that cover and the unit, which exchanges air, flow between freezer and refrigerator. I then removed the two screws, which held the thermostat in place. I then removed the thermostat with the sensor and the white tube, which covered it. Then I removed the white tube from the sensor.

To install the new thermostat I first inserted the thermostat sensor into the white tub. I lubricated the sensor with a very small dab of Vaseline. Then I placed the sensor unit in the unit, which exchanges air between refrigerator and freezer. I next reinstalled the unit, which exchanges air between refrigerator and freezer. Then I reinstalled the cover over the thermostat sensor. I then installed the thermostat with the two screws, which held it in place. Then I reinstalled the cover the thermostat with the four screws, which held it in place. Last I snapped the cover plate in place.

Our six year old fridge would not stop running - everything was frozen. Found if I tapped on the Tstat I could sometimes get it to turn off.

  • Customer: Jeff from Belleville WI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 19 of 20 people found this instruction helpful
Remove the knobs and faceplate to get at the screws behind it. Removing the sensor is a bit involved but everything else is fairly straight forward. See other postings for description / order of operation. Replacement took less than 30 minutes.
Works great now!

Door was making a clunking noise

  • Customer: Erik from Yorba Linda CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 19 of 20 people found this instruction helpful
The door is very easy to remove. There is one nut for the cap on the top of the soor hinge. Once the cap is removed, you need to remove the 3 nuts holding the hinge in place. Simply lift the door off the lower hinge and rest it on the dining room table. I set towels down to protect the stainless finish. The closing cam will be visible on the bottom of the door. I choose to replace the lower cam and the upper cam at the same time. I did not know what the problem cam was. The door works good as new. I put a small amount of vaseline where the two cams rub to provide a lubricant.

Light Would Not Go On In The Refrigerator

  • Customer: DANIEL from MINNEAPOLIS MN
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 20 of 24 people found this instruction helpful
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the lead wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!

refrigerator was intermittently cooling because thermostat contacts burned away.

  • Customer: Dennis from Westlake OH
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 18 of 19 people found this instruction helpful
Turn off the fridge and unplug the power. Inside the refrigerator unit, remove two plastic panels extending from the front to the rear cooling vent by unscrewing two screws. Gently unhook the thermostat tube from the rear vent.

On the control panel, gently pry off the two control knobs and the front control panel. Remove four screws to drop down the control assembly. Unplug the left electrical connector and unscrew the lever control arm being careful not to bend it. Disconnect the right side electrical connector and you can now remove the control unit to a table to easily work on it.

Undo two screws to remove the thermostat bracket. Undo two more screws to remove the thermostat assembly. Install the new thermostat and reverse the process just described. It takes about 15 minutes if you know what to do ahead of time. You will have to reuse the plastic tube that covers the thermostat sensing tube.

broken shelves

  • Customer: Maria from Albuquerque NM
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 22 of 34 people found this instruction helpful
replaced with new shelves