Models > 25395 > Instructions

25395 Kenmore - Instructions

All Instructions for the 25395
1 - 13 of 13
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Clicking sound then within a minute clicking again, not cooling.
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it rattles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
Parts Used:
Compressor Start Relay
  • Melvin from Semmes, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
79 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stopped working, cooling.
I used a small screwdriver to disconnect wires from old starter. I connected the overload and starter, two wires. I put the unit back in the keeper, plugged the unit in, turned up the thermostat and it's working beautifully.
Parts Used:
Compressor Start Relay
  • Jennifer from Jonestown, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer quit. Compressor would not start.
Like another post, the start relay rattled like a baby rattle. Replaced the start relay and freezer works great.
Parts Used:
Compressor Start Relay
  • Steve from Neosho, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
mottor starts than stop.
i looked byhind the freezer , the mottor has the relay connected to it.i took out the relay, and i descovery something was loose inside, i decided to take to check out at sears to see if they have in stock that especific relay. they did not have, they could order, that's when i dicided to go ahead and looking for in the internet, good i found PARTSELECT,they had the part and i was very nice attended,they sent in 2 days i had fix my freezer. thanks PARTSELECT. gilmar couto.
Parts Used:
Compressor Start Relay
  • Gilmar from Miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would run continuously and not shut off
Removed the front cover and then the humidistat from the bracket. Two push on wire connectors and then reversed. Very straightforward and excellent part matching. Given the prices for new dehumidifiers it was great to breathe life back into this unit which does its job well. Thanks for the easy to use web site and fast fast service!
Parts Used:
Humidistat Control
  • Jonathan from New Oxford, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The float turned up missing during a move to another city.
The repair was just putting the float into the inside of the tank itself and then, inserting the two pins (left and right) into each slot so the float operates up and down freely.
Parts Used:
Float
  • Gregory from MARINETTE, WI
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
We lost the water float. Needed a replacement
The float has two prongs that fit two snap fasteners on the reservoir tank. I just pressed the float prongs into the snap fasterners and inserted the reservoir tank into the dehumidifier. Turned the switch and pressto! We are in business.
Parts Used:
Float
  • Bob from Omaha, NE
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replaced the float in my dehumidifier
Snapped the float into the slot. That was all there was to do.
Parts Used:
Float
  • Gwendolyn from COLUMBUS, OH
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dehumidifier would not shut off automatically
Remove the front cover 2 screws on the bottom. Then removed the clip for the full light, then removed 2 more screws that held the humidistat. Removed the 2 power wires removed part. Reverse the uninstall procedure. Done
Parts Used:
Humidistat Control
  • Kerwin from BUFFALO, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dehumidifier would not shut off
First I pulled the top/side cover off. Disconnected the terminals from the old unit, unscrewed the old unit, and put the terminals on the new unit. Then I put the side/top cover back on, screwed the new humidistat unit into the front cover and then popped and screwed the front cover back in place. Customer service was excellent and order was received promptly as promised. Highly recommend Parts Select!
Parts Used:
Humidistat Control
  • William from Allentown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Humidifier would not shut off
Removed cabinet and grill. Humidistat held in by 2 screws and a 3-wire harness. Dehumidifier working like a charm with the new part.
Parts Used:
Humidistat Control
  • John from Presque Isle, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dehumidfier wouldn't turn off.
First I removed the two control knobs and the two screws that hold the front cover in place and then the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires. Then I reconnected the new humidistat and put everything back together. Works just fine, now.
Parts Used:
Humidistat Control
  • Michael from Bethesda, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
awasome
After reading reviews I was not sure but I ordered part on Wensday in the AM and I had the correct part Thursday evening this company rocks thank you by the way i paid for regular shipping I will order again in a heartbeat
Parts Used:
Compressor Start Relay
  • chris from springfield, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25395