The compressor would not run.
I removed the cover, used a multimeter to test the compressor circuit, and found the compressor start relay to be defective. Ordered a new one and installed it when it arrived.
Removed the cowling with a square drive screw driver, removed the spring clip from the cover of the compressor controls with a screw driver, pulled off the old compressor start relay and replaced it with the new part. Since other problems could have caused the compressor to short cycle this was a "replace the part and hope it would work" since that would be the most common reason and it was not a very expensive part.
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement switch.
After the refrigerator stopped cooling, we determined that the problem was in the compressor area. we used a screwdriver to get the cover off and then vice grips to get the actual pieces out (start relay & overload)--they broke, but they were already broken). We went to the Home Depot site to purchase the parts, but found PartSelect to be much less expensive. Put the parts in when they came a few days later and it worked! thank you PartSelect!
Freezer would not run ... replace the compressor start relay which fixed the problem
Pulled out the freezer. Unplugged. No freezer back cover was there. The compressor start relay was in a plastic encasement attached to the compressor - wires led me to it. Removed the solid metal spring with a screwdriver and removed the plastic cover. Tried to pull out the defective relay but the freezer was so old I needed a pliers to remove it. When I put pressure on the old relay with the pliers the relay broke and came off in pieces. I then removed the wires from the broken parts and put them on the new relay. I pushed the new relay onto the 2 pins then replaced the cover and spring. After plugging the freezer in the problem was fixed.
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
I removed the compressor start relay and replaced it with the new part. Initially it did not work. When I checked my work, I had to tighten the connector on the new part. Once I made the correction, the freezer is freezing normally again.
After first ordering the wrong end part, I reordered the correct part and successfully attached the handle end and handle to the refrigerator door. The handle itself was too long, and I had to cut it down to the correct size. I am a realtor and provided the service to my buyer of the condo that was my listing. Thank goodness for your company and the ability to buy parts for an old model!
simply snap R end cap into R slot in door, then slide one end of retainer bar into R end cap, other end of retainer bar into L end cap, then snap L end cap into L slot in door.