washer wouldn't agitate

  • Customer: mike from Kent WA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 474 of 478 people found this instruction helpful
First pry off the cap of the agitator. Then using a socket remove the bolt that holds the plastic cup in place. Remove this cup by prying it loose from the two tabs that hold it in place. Once this cup is removed you can get to the broken cogs.
Slip the new cogs into the underside of the cup, and slide the cup back down in the agitator housing using the slots on the side for a guide. (You may want to remove the entire agitator and assemble everything upside down, then flip it all back over to mount, so the cogs don't fall out).
Tighten the bolt, snap the cap back in place on top of the agitator and your'e done. Easy repair.

top half of agitator did not move during wash cycle

  • Customer: dennis from new stanton PA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Socket set
  • 174 of 198 people found this instruction helpful
pull off softner dispenser, pop off agitator cap by inserting straight screw driver into small slot, remove bolt inside agitator with socket wrench and long extension, pull agitator straight up off shaft, place agitator on floor, with feet holding bottom half pull top half apart from bottom half by pulling straight up, note direction of old cogs remove and replace with new, reassemble

Agitator was not working

  • Customer: Michael from Murray KY
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Socket set
  • 37 of 44 people found this instruction helpful
Step 1) Take off top cap with a flat head screw driver.

2) unscrew bolt (may need extension as it may be deep in the agitator.)

3) Take upper agitator off.

4) remove clog retainer and clogs.

5) insert new clogs and re-assemble.

total time 10 to 15 min.

Upper agitator stopped moving

  • Customer: Craig from Yadkinville NC
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 19 of 23 people found this instruction helpful
First, I removed the softner cup from the top of the agitator. Second, I removed the plastic seal by pulling it out. I then used a socket to remove the bolt holding the agitator down. I then removed the agitiator from the machine and seperated the upper and lower agitator by placing my feet on the lower agitator and pulling up. The dog-ears were in the upper agitaotr section and easy to see and replace. I re-assembled in reverse order. The whole process took less than 30 minutes.

Top Half of Agitator would not function without appying sideways pressure

  • Customer: Donald from Fredericksburg VA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set
  • 15 of 17 people found this instruction helpful
Heard about the website... 1 minute to find it, 10 minutes to order new cogs... 3 day wait for new parts... Rec'd Fedex, 15 minutes total to pull the agitator cover (bleach dispenser) then the bung cover with o-ring (just lift out) expose bolt, unskrew and remove top portion of agitator or entire agitator if it's easier. Seperate, remove black cog holder (slides up the spindle) and replace cogs one at a time just like the old ones. Reassemble in reverse and you are back in business. Saved the $75 deductible on my home appliance warrenty. You guys are the best... cheers...

Cog stripped causing agitator to not turn

  • Customer: Vicki from Houston TX
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Wrench set
  • 12 of 14 people found this instruction helpful
Removed top cap on agitator w/ flathead screwdriver. Removed protective cap over bolt and cog housing shaft. Used 7/16 deep socket w/ extension to remove bolt. Removed housing where stripped cogs were located. Cogs seated loosely in shaft housing no tools required to remove cogs. Replaced cogs in housing, made sure everything was lined correctly. re-inserted housing into shaft. ,screwed bolt, replaced caps and works like new.

Scratches in Surface

  • Customer: Michelle from Richardson TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 10 of 12 people found this instruction helpful
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.

Agitator moves freely in both directions

  • Customer: James from NAPERVILLE AL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Wrench set
  • 9 of 11 people found this instruction helpful
First I removed the softener bin by pulling it up and off, then I removed the plastic seal by pulling it up and out, then I removed the 1/2 inch bolt with a ratchet and extension, then I removed the upper and lower agitator assembly from the machine and seperated the two by putting my feet on the lower agitator to hold it to the floor and pulling the upper agitator fast and firmly.
Sitting on top of the lower agitator I found the dog ear assembly. I pulled the dog ear assembly off and removed the yellow cap and existing dog ears.
Assembly was reverse.

Agitator was barely agitating. Making a clicking noise.

  • Customer: Charmaine from Slidell LA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set
  • 8 of 9 people found this instruction helpful
Removed agitator cap. Removed bolt inside with socket wrench. Located plastic cogs Pulled out old cogs and slid in new cogs and put back together and works great. Easy to take apart and put back together. Very cheap repair. Cogs less that $4.00 plus shipping. Shipped next working day.

top agitator would not operate

  • Customer: Larry from Edgewood TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Socket set
  • 7 of 7 people found this instruction helpful
unscrewed a bolt, pulled top agitator out and replaced parts and reinstalled.

Top section of agitator would not spin.

  • Customer: Russell from Hyannis MA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set
  • 6 of 7 people found this instruction helpful
Used your exploded view of the area to determine the problem-found the broken part and reassembled following the drawing. I felt like a pro after a test and kept my wife happy. [only lost a few days waiting for the parts which arrived as expected]

Lid Lock light blinking, machine will not start

  • Customer: David from Los Alamos NM
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 7 of 10 people found this instruction helpful
A detailed Service Technician Service Manual is hidden inside the machine on the front panel. It is hidden by the bleach dispenser input. It gives a list of fault codes and instructions for calibration after repair, resetting fault codes, and a manual test mode for stepping the machine through each mode on command. The Tachometer failed which would not let the machine come up to maximum spin speed. The tachometer is part of the solenoid actuator that shifts the transmission. It is not specifically called out in the manual. Any failure causes the lid lock light to blink which gives the appearance of a lid lock failure

Top agitator did not work

  • Customer: George from Danbury WI
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 3 of 3 people found this instruction helpful
I removed the cover for the softener dispenser on the top of the agitator. Then reached in and removed the cover of the nut and washer which was very sticky and sealed with an o-ring. This took a bit of pressure. Then used a socket wrench with an extension to loosen the bolt and took the whole agitator out of the machine. Then I set the agitator on the floor and with a fine 12 inch long screw driver released the catches while turning and pulling the agitatior with my other hand and holding the lower agitatior on the floor with my feet. I then turned the upper part over and removed the cogs and holding mechanism.
Then I reversed the process after replacing the cogs with the new part. 25 minutes total.

Replaced the dog ears.

  • Customer: Todd from Milwaukee WI
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Socket set
  • 2 of 2 people found this instruction helpful
It was easy, take off the cap, then loosen the nut. Take it apart, change the dog ears, put back together. It was done.

The top agitator was not spinning

  • Customer: Alec from Indianapolis IN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Socket set
  • 2 of 2 people found this instruction helpful
I popped the dispenser cap off, pulled off the plastic cover that sits on top of the agitator directional cogs assembly, and used a socket wrench with 2 extensions on it to unscrew the nut holding the assembly in place. I misplaced my socket screwdriver and rather than try to buy a nutdriver that matched the size, I just bought a little 3/8" socket extension kit (I needed about 8" of length to be able to use a normal socket wrench). My hands are pretty big so I just had to use pliers to pull the agitator cogs assembly out. Next I just turned the assembly upside down, slipped the plastic ring off that holds the cogs in place, and put the new cogs in place of the old ones. Reassembly was just as easy. The job took about 15 minutes, and once everything was back together the agitator worked like it was brand new.