Ice Maker quit working, I could manually cycle unit but then the water would overflow when unit was re-filling.

  • Customer: Max from Green Castle IN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 488 of 495 people found this instruction helpful
I backed out the 2 top screws about a quarter inch and then removed bottem screw with a quater inch nut driver. I then lifted Ice Maker clear of the two top screws and lowered it enough to unclip the power connection with a small screwdriver. The new Ice Maker was wired correctley for my refrigeator so all I had to do wea reconnect the power connection and mount new Ice Maker on the two top screws and install the bottem screw. It took e while for the new Ice Maker to start it's cycle but after it did, it worked GREAT. Part Select service was OUTSTANDING, ordered part one day and received the next. THANKS!!!!

No ice

  • Customer: Daniel from Suwanee GA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 307 of 367 people found this instruction helpful
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.

No Ice in the Ice Maker

  • Customer: Chris from Duluth GA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Socket set
  • 142 of 156 people found this instruction helpful
I am NOT a handyman, and my family laughed at me when I said I was going to fix the ice maker all by myself. I ordered a replacement ice maker. When it arrived, I opened the box and read the instructions. It seemed easy. I removed the old ice maker, with a socket set. I then took off the shut off lever from the old one and placed it on the new one, since the new one didn't come with it. I then put the new one in place. All the parts fit perfectly. The ice machine was making ice within an hour. My family was amazed... and I got the last laugh!

My refrigerator stopped cooling and the freezer section stopped freezing

  • Customer: garth from forest lake MN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 103 of 111 people found this instruction helpful
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!

Ice Maker stopped working

  • Customer: Robert from Port Washington NY
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 81 of 91 people found this instruction helpful
With socket wrench un-screwed the 3 screws and pulled out the ice maker assembly.

Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)

However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part.

Unscrewed the motor assembly (3 screws) with phillips head screw driver.

Screwed in the new unit.

Placed ice maker back into location and tightend the bacing srews.

1 hour later ice was falling!

icemaker leaking infreezer compartment

  • Customer: John from Oberlin LA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 76 of 92 people found this instruction helpful
first I backed off top two screws and removed bottom screw. unplugged wire harness. removed old icemaker. harness on new icemaker was the same. plugged in hung new icemaker on top two screws installed bottom screw. turned water on job complete and very easy. I was very satisfied with the whole process.

The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.

  • Customer: David from Chester CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 62 of 75 people found this instruction helpful
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.

Inlet valve broken from freezing in Storage

  • Customer: John from Lincoln NE
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 60 of 71 people found this instruction helpful
Simply remove 5 or 6 self tapping screws to lower the cardboard backing with a 5/16 nut driver. Loosen two screws that hold the valve to the metal lip low on the back. Push 3 easy-connect fittings towards the valve while pulling the poly tube out at the same time. Replace the tubes by simply pushing into the fitting. I did these one at a time so I wouldn't get them mixed up. Fasten the valve back onto the metal lip, and screw the cardboard back on. Move the Fridge back and the job was all done~!

Fridge was warm. No air circulating at all. Food was spoiling Fridge was just over 1 year old

  • Customer: Brian from Smock PA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 49 of 55 people found this instruction helpful
First I removed the two screws that secure the guard in bottom back of the freezer and removed it . Next I removed the two screws that secure the guard on the back wall of the freezer and removed it. There are three wires connected to the motor, I unplugged those and removed the two screws that secure the motor and removed it. I swapped the grommets, blade and support bracket from the old motor. I put it back together in reverse steps and its working great. My mother-in-law can,t stop thanking me ! I saved her at least $400 to buy a new fridge. Thank You, Brian Miner

Icemaker made a clicking noise then quit making ice

  • Customer: Ryan from Layton UT
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 51 of 65 people found this instruction helpful
Motor from Part Select was 185W instead of 260W that came out of unit. After a bit of searching online, I found out the 260W had been obsoleted for lack of torque when harvesting ice.

Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.

No ice in ice trey

  • Customer: Wayne from Leesburg FL
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 42 of 49 people found this instruction helpful
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace holding pins and start the process of putting back together the opposite way you took it apart.

water dripping inside fridge due to drain hole being frozen over wiith ice.

  • Customer: Edwin from Maplewood NJ
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 37 of 43 people found this instruction helpful
first I diagnosed the problem with the whirlpool do-it-yourself repair manual, which was very easy to understand. as per the repair manual, "this part located on the evaporator or the back of the liner is used during the defrost cycle. This bimetal senses the temperature from the evaporator. When the temperature reaches 50-70 degrees (F) the defrost bimetal turnd the defrost heater off. " then I emptied the freezer. removed the the back panel to expose the evaporator. I looked for the bimetal defrost thermostat clipped on the evaporator. tested the bi-metal defrost thermostat, as per the manual, " the ohmmeter should show ZERO resistance (continuity). if not, the bimetal is bad and needs replacing." NOTE: the bimetal must be cold. it is also tested with the bimetal warm/hot, by running it under hot water. i used a styrofoam cup with hot water & dipped the bimetal in. as per the manual, " the ohmmeter should show an open circuit. if not, the bimetal is bad and needs replacing. then got online found partselect.com. ordered the part, recieved it in less than 2 days. within minutes after recieving the part, I removed the bimetal defrost thermostat and spliced in the new one. thanks to partselect.com my fridge is back up and running properly again. prior to installing the new bimetal, i tested it, as descibed above, you can hear & feel the bimetal open/close when it gets hot/cold.

Icemaker would not stop putting out water, then would not make ice

  • Customer: Phil from Felton DE
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 36 of 43 people found this instruction helpful
First, I unplugged the power to the entire fridge, and then removed the ice tray and ice door. Next, I unplugged the flat plug in the very back left behind the icemaker. Then I removed the 1/4" hex head sheet metal screws (2) and the phillips head screw (1) that hold the icemaker to the left side of the freezer wall. New icemaker came with a different style trip arm, so I used it. Plugged new icemaker in before reattaching it with the same (3) screws. Replaced ice tray and door, plugged in fridge, and waited....Dumped its first batch of ice maybe a couple of hours later. Not much trouble-shooting is needed when the entire icemaker is as easy and relatively inexpensive to replace as this. Twenty minutes, max.

Lights inside refrigerator not working

  • Customer: Clint from Rayville MO
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 36 of 43 people found this instruction helpful
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.

Ice maker quit making ice

  • Customer: Dean from Pahrump NV
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 32 of 36 people found this instruction helpful
I removed the ice maker which required removing 3 screws and then disconnecting the electrical plug. Once the ice maker was out, I removed the 3 screws that held the motor assembly to the unit.
I removed the motor, replacing it with the new one.
Plugged the power supply cord back in, replaced the unit with the 3 screws and within a few minutes the unit was receiving water and by the next day I had ICE. This saved me $50. for the service call, then another $25.00 installation fee when the part came in (had to be ordered) plus the markup on the motor (approx. $25.00) So I saved approx. $100. and only took about 30 min.