No ice

  • Customer: Daniel from Suwanee GA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 313 of 373 people found this instruction helpful
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.

Ice Maker quit working, I could manually cycle unit but then the water would overflow when unit was re-filling.

  • Customer: Max from Green Castle IN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 491 of 498 people found this instruction helpful
I backed out the 2 top screws about a quarter inch and then removed bottem screw with a quater inch nut driver. I then lifted Ice Maker clear of the two top screws and lowered it enough to unclip the power connection with a small screwdriver. The new Ice Maker was wired correctley for my refrigeator so all I had to do wea reconnect the power connection and mount new Ice Maker on the two top screws and install the bottem screw. It took e while for the new Ice Maker to start it's cycle but after it did, it worked GREAT. Part Select service was OUTSTANDING, ordered part one day and received the next. THANKS!!!!

The frost free feature of the freezer was freezing over with ice and cooling coils were being insulated with thickening frost which caused the cooling air to rise in temperature from -5 degrees to 20 degrees.

  • Customer: Lawrence from Grahamsville NY
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver
  • 196 of 236 people found this instruction helpful
I troubleshot the problem by reading the electrical schematic and concluding the heating elements (defrost cables) were either defective or the bi-metal temp sensor was open. When closed the temp sensor completes the circuit for the current to flow through the heaters to defrost the cooling coils every 8 hours and then when the bimetal opens at 55 degrees the circuit is open and the coils are cooled because the refridgeration motor is in run mode. A timer between the motor and heater elements also was defective. The timer controls the cooling period and the defrost period. I ohmed out each part according to the spec sheet of normal resistance of parts and thus the bimetal and timer were defective. I gather a surge of some duration and amplitude affected these parts because a storm 24 hours prior to refridgerator problem had passsed through the area and the AC electrical power had oscillated several times during that event. I used hand tools to do the repair. If you are not mechanically inclined a step by step proceedure would be moot. It is a matter of disassembly and assembly paying close attention to fragile parts.

No Ice in the Ice Maker

  • Customer: Chris from Duluth GA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Socket set
  • 142 of 156 people found this instruction helpful
I am NOT a handyman, and my family laughed at me when I said I was going to fix the ice maker all by myself. I ordered a replacement ice maker. When it arrived, I opened the box and read the instructions. It seemed easy. I removed the old ice maker, with a socket set. I then took off the shut off lever from the old one and placed it on the new one, since the new one didn't come with it. I then put the new one in place. All the parts fit perfectly. The ice machine was making ice within an hour. My family was amazed... and I got the last laugh!

My refrigerator stopped cooling and the freezer section stopped freezing

  • Customer: garth from forest lake MN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 103 of 112 people found this instruction helpful
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!

Sometimes the condenser fan would start causing the refrigerator to overheat.

  • Customer: Tom from Franklin WI
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 88 of 91 people found this instruction helpful
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new

Ice Maker stopped working

  • Customer: Robert from Port Washington NY
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 81 of 92 people found this instruction helpful
With socket wrench un-screwed the 3 screws and pulled out the ice maker assembly.

Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)

However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part.

Unscrewed the motor assembly (3 screws) with phillips head screw driver.

Screwed in the new unit.

Placed ice maker back into location and tightend the bacing srews.

1 hour later ice was falling!

icemaker leaking infreezer compartment

  • Customer: John from Oberlin LA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 77 of 93 people found this instruction helpful
first I backed off top two screws and removed bottom screw. unplugged wire harness. removed old icemaker. harness on new icemaker was the same. plugged in hung new icemaker on top two screws installed bottom screw. turned water on job complete and very easy. I was very satisfied with the whole process.

The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.

  • Customer: David from Chester CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 62 of 75 people found this instruction helpful
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.

Icemaker made a clicking noise then quit making ice

  • Customer: Ryan from Layton UT
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 51 of 65 people found this instruction helpful
Motor from Part Select was 185W instead of 260W that came out of unit. After a bit of searching online, I found out the 260W had been obsoleted for lack of torque when harvesting ice.

Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.

No ice in ice trey

  • Customer: Wayne from Leesburg FL
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 42 of 49 people found this instruction helpful
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace holding pins and start the process of putting back together the opposite way you took it apart.

Temperature unstable

  • Customer: Duane from Albany OR
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 41 of 52 people found this instruction helpful
Open the door. Removed two screws holding the cover of the thermostat. There is a clip which holds the thermostat in place. Remove the clip. Take out the thermostat. Remove the thermocouple (the long grey metal with the coil at the end) which is also held in place by a clip. Replace with the new thermostat and thermocouple and clip into place. Replace the screws to the cover. Close the door.

water dripping inside fridge due to drain hole being frozen over wiith ice.

  • Customer: Edwin from Maplewood NJ
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 38 of 44 people found this instruction helpful
first I diagnosed the problem with the whirlpool do-it-yourself repair manual, which was very easy to understand. as per the repair manual, "this part located on the evaporator or the back of the liner is used during the defrost cycle. This bimetal senses the temperature from the evaporator. When the temperature reaches 50-70 degrees (F) the defrost bimetal turnd the defrost heater off. " then I emptied the freezer. removed the the back panel to expose the evaporator. I looked for the bimetal defrost thermostat clipped on the evaporator. tested the bi-metal defrost thermostat, as per the manual, " the ohmmeter should show ZERO resistance (continuity). if not, the bimetal is bad and needs replacing." NOTE: the bimetal must be cold. it is also tested with the bimetal warm/hot, by running it under hot water. i used a styrofoam cup with hot water & dipped the bimetal in. as per the manual, " the ohmmeter should show an open circuit. if not, the bimetal is bad and needs replacing. then got online found partselect.com. ordered the part, recieved it in less than 2 days. within minutes after recieving the part, I removed the bimetal defrost thermostat and spliced in the new one. thanks to partselect.com my fridge is back up and running properly again. prior to installing the new bimetal, i tested it, as descibed above, you can hear & feel the bimetal open/close when it gets hot/cold.

No water feed to icemaker

  • Customer: Robert from Abingdon MD
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Wrench set
  • 40 of 52 people found this instruction helpful
To troubleshoot - Check water supply to valve. It f that's good - remove back plate, remove water valve reconnect inlet line, disconnect electrical connector, place valve over a pan with outlet fitting disconnected, temporarily connect 110 VAC with clipleads to water valve solenoid. No water flow means valve is not opening. To install new valve, connect outlet line, and wiring connector, then insert in cabinet and install 2 screws, reinstall back plate, connect water inlet line.

Lights inside refrigerator not working

  • Customer: Clint from Rayville MO
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 38 of 46 people found this instruction helpful