water to ice maker not shutting off; overflowing

  • Customer: g anthony from salt lake city, UT
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 37 of 42 people found this instruction helpful
1. turn off power.
2. pop off ice maker cover to access motor assembly.
3. remove three screws to assembly.
4. pull off assembly.
5. attach new assembly making sure metal arm and plastic
ice tray rod align with assembly.
6. screw assembly onto unit.
7. replace cover.
8. plug in refrigerator.
9. enjoy ice again with no leakage into freezer.

No Ice, Water did not fill icemaker

  • Customer: Barbara from Davenport, IA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers, Wrench (Adjustable)
  • 41 of 55 people found this instruction helpful
We weren't sure if the problem was in the Water Inlet Valve or in the Icemaker Control & Motor Assembly. The water in the door did work. We removed the Water Inlet Valve & tested it with an Ohm Meter. It tested good so we put it back in. We then ordered the Icemaker Control & Motor Assembly. When it arrived we installed it and waited a few hours but the icemaker still did not fill with water. We telephoned a parts store and were told the problem could be the thermostat or we could replace the whole icemaker. We replaced the whole icemaker.

Ice door was broken

  • Customer: Ray from San Antonio, TX
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 38 of 46 people found this instruction helpful
1) At bottom of ice maker trim there are two small slots at right and left ; use screw driver to pry away from door; lift trim upward away from door 2)using 1/4" nutdriver remove screws from 4 corners, 3) remove 2 screws from control panel 4) disconnect all wires/cables and set exterior panel aside. 5) locate 2" pin that runs through door spring and use needle nose pliers to remove round clip on left end of pin don't lose this clip 6) while pushing ice maker lever (where you would push with your glass) use needle nose to pull the long pin out to the right 7) Remove all remaining parts by hand (i.e. the pin, the dash pot and white lever and the ice door) 8)slide new control lever into slots on exterior side of the new door 9) -tricky part- using needle nose, push pin back through the right hinge point, the new lever, the new door, the new spring and the left hinge point (note the new door has no electric wire connector) 10) using the needle nose, carefully replace the little round clip on the left end of the metal pin. 11) reconnect all the wires (don't worry about the wire that had been connected to the door wire, just fold it aside) 12) replace two screws screws in control panel and four screws at corners of exterior panel 13) snap outer trim panel back in place.

Stopped Cooling

  • Customer: David from Navarre, FL
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 35 of 45 people found this instruction helpful
I removed the back cover to gain access to the compressor. I unpluged the start device and cap from the compressor. Replaced the items with the new ones. Plugged in the refridge and it worked. Whirlpool/Kitchenaid appliances are problems. I won't buy another.

The ice maker stopped producing ice.

  • Customer: Robert E. from Payson, UT
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 30 of 32 people found this instruction helpful
If you remove the bottom vent panel of the refrigerator there are two schematics for the refrigerator. One for the fridge and one for the icemaker. The icemaker has an emitter and a receiver that will tell the icemaker when it is ok to dump ice and add water. The receiver has an LED that blinks different codes. The codes give you an idea where your problem is located. In my case it coded out to be the optics (emitter and receiver). Replacement of the parts involves the removal of three screws on each component and disconnecting a wire harness on each component. Install the new components by following the removal process in reverse. The total cost was $80.00. This was half the price Sears wanted for the parts and about the same price to have a Sears repairman just show up at the house.

Door chute broken

  • Customer: Dwight from Marietta, OK
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 33 of 43 people found this instruction helpful
First removed the outside cover plate which was some what scary not to break plastic cover. Had read about another discription of removal of cover to start from the bottom because the top is inserted in slots that would have broken if removed from the top. After cover plate removed it was simple to remove the broken parts and install the new parts. The most difficult part to put back in was the spring and rod had to be inserted the same time.

Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up

  • Customer: Robert from Doral, FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 33 of 43 people found this instruction helpful
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good

Compressor "grounded" and quit running

  • Customer: Mike from Baytown, TX
  • Difficulty: Easy
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Wrench (Adjustable)
  • 55 of 111 people found this instruction helpful
Replaced the compressor with the new one I purchased from you. Installed new parts and recharged unit. The refrigerator / freezer is working better than new. Thanks for the great deal on the compressor. It was here in 3 days. All the parts fit exactly and had no difficulty in the installation or startup. The directions for the wiring were a great help also. Thanks again.

The icemaker stopped filling the ice tray to make ice.

  • Customer: shannon from sierra vista, AZ
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers, Socket set
  • 29 of 34 people found this instruction helpful
I checked the fuses and hoses in the back of the refrigerator to make sure water WAS in fact getting to the front of the fridge. Since the water through the front door worked fine, I had to check the water tube running to the ice maker. It was fine and water was waiting to go somewhere! I decided to pull the icemaker out of the fridge to see what I could fine. Once it was out, I took the ICEMAKER CONTROL AND MOTOR ASSEMBLY off (that's the side part with the dial on it). Only 3 screws to take that off, and it was EASY to see what was wrong once I took that off. There was a connection that was obviously bad (looked almost like it had burned out). My thought was that it was obvious what part was bad, what would it hurt for me to try to fix it myself? When I got online to find the part, PartSelect was the only one that I found that had the EXACT part that I needed, and lucky for me, there were multiple pictures of multiple angles of the part so I could compare and make sure I had the right one!! The part with shipping cost less than the cost of a repair tech to even come out and look at the fridge. Then add the cost of the part and labor if I had the repair tech fix it...I probably saved about $250!!!!

ice maker did not make ice

  • Customer: DAVID from TINLEY PARK, IL
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 31 of 42 people found this instruction helpful
The ice maker was not getting water. I hotwired the water valve by switching the connectors for the water dispenser and ice maker water valves and water flowed into the icemaker when the water dispenser lever was pushed. I wronly assumed the water valve was good. I removed the icemaker and determined that the gear motor was not getting power in the position the icemaker had stopped.In this position, the thermostat determines when the motor gets power so I replaced the thermostat. The icemaker still would not get water! As it turns out, the water solenoid was sticking due to a deteriorated rubber washer which let the solenoid plunger get too far out of the magnetic field. I replaced the water solenoid assy and all is well. Don't get fooled by hotwiring the valve. If it isn't getting water, the solenoid probably is the culprit.

One finger of the spring steel peice that holds the ice maker and water dispenser levers out broke.

  • Customer: Ron from Newton, IA
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Socket set
  • 30 of 39 people found this instruction helpful
I removed the screw holding the spring steel retainer/clip using a quarter inch ratchet wrench a swivel with a quarter inch socket and a short extention, then just installed the new one. This spring steal through the door ice maker / water despenser lever spring was an easy fix.
I found you by googling appliance repair parts, and found your site really easy to use. I couldn't believe how fast the part came and the very reasonable price. I put you on my web browser's favorites.
Thanks,
Ron

tracks for the deli drawer were broken

  • Customer: Terri from Wichita, KS
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 26 of 28 people found this instruction helpful
I removed the old tracks and installed the new ones. There were small round protrusions on the new tracks that prevented me from sliding them into the brackets in the refrigerator so, I filed them down with a fingernail file and then they slid right into place.

My ice maker stopped producing ice. It would dispense ice that was already made and the water dispenser worked.

  • Customer: Glenn from San Marcos, CA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 25 of 26 people found this instruction helpful
I looked at some online diagnostics info and the owner's manual. The "error code" blinking red light on the receiver unit (located adjacent to the ice bucket) indicated that the emitter/receiver units were faulty. I located the parts on the PartSelect website (their price was less than half of what they wanted on the Sears website) and ordered them. I didn't pay for the expedited shipping and still received the parts within two days of ordering. Powered down the refrigerator, three simple screws to remove each cover for the emitter and receiver, unplug the old units and pop in the new units, replace the covers for each unit, repowered the fridge and, voila, you've got ice. I completed the repairs in less than 10 minutes. Couldn't be happier with the price, the diagnostics links/info or the prompt service. Next time I have an appliance issue, my first stop will be this website.

Frige Door Wouldn't Stay Closed, Would open when freezer door was closed.

  • Customer: Michael from Las Vegas, NV
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 26 of 29 people found this instruction helpful
Parts arrived at 2:30PM.

Read instructions, gathered tools, and went to work. I'd already watched an online video at your site on how to do the repair.

Removed the hinge cover covering the hinge top by using a nut driver to remove the single screw holding it in place. (The video described an older frige and it did not have a screw. I figured that out when I finally went and got a ladder. I had tried to pop it out like the video shows.) There are three screws holding the hinge top in place. I tried using the nut driver to remove the screws but they were pretty firmly in place. I resorted to using my ratchet wrench and that made it easy. (Keep track of your screws, one of mine rolled under a cereal box on top of the frige and I thought I would never find it.)

I had emptied out all the items on the door of the frige, removing the shelves. It was easy to lift the door off of the bottom hinge and lay it on its side against the ladder. At this point I had my son hold the door steady (its kind of unwieldy and 'slippery' when you are trying to remove a screw from the bottom of the door.)

I removed the screw that held the plastic Door Closer, Upper Cam using the nut driver. I used a straight bladed screw driver to pry the old part out of the door (it has an insert for the hinge pin and it had been in place a long time). I also cleaned off the bottom of the frige door (you would be surprised what gets stuck on there - obviously someone spilled oranged juice on the floor and it splashed up on the bottom of the door). The old part had a lot of particle dust that came off it when I removed it. The new part popped right into place and I screwed it back in. The video shows that the repairman had to use a drill and tap set to rethread a larger hole but I just put the old screw back and it held fine. The video also showed the repairman adjusting the Door Stop Bracket but I didn't have to do that, the new cam installation wasn't impeded by the bracket.

I moved to the frige cabinet (again, good to have a second pair of hands to keep track of the door and not let it get damaged while I turned my attention to the Door Closer, Lower Cam. I used the nut driver to remove the screw holdin it to the hinge bottom. It came off easily (it practically fell apart and turned to dust). I placed the new cam and screwed it in using the old screw. No problem.

You could put the door back on with one person but it helps to have two. One to manhandle the door and the other to place it on the lower hinge post.

I put the upper hinge back on and put in the three screws but I left them lose so that I could adjust the door. When I tighted the single screw closest to the door after positioning the door, we tested how it opened and it was hitting the side of the interior cabinet when it closed - you could feel it dragging and it made a clunk/swoosh sound. We readjusted the door using the outside upper corner as a guide and retightened the screw. This time there was no problem. We tighted the other two screws using the ratchet wrench and then put the plastic hinge cover back on with the single screw using the nut driver.

Took us about 25 minutes and made my wife very happy (biggest benefit). The door now 'locks' open and 'locks' closed just like when we bought it and the two doors are aligned (level accross the top) which should have been a dead giveaway that the door closing cams had worn down.

Done by 3:00PM.

Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID

  • Customer: James from Ringoes, NJ
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 27 of 35 people found this instruction helpful
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat. Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.