Models > 10650594001 > Instructions

10650594001 Kenmore Refrigerator - Instructions

All Instructions for the 10650594001
1 - 15 of 1331
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
replacing parts only
the prices you had were great, now I see there was an increase in the parts.
thank you
Parts Used:
Refrigerator Door Shelf Bin Refrigerator Crisper Drawer with Humidity Control
  • JULIA from BRONX, NEW YORK, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
690 of 767 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.
Parts Used:
Icemaker Control Assembly
  • Daniel from Suwanee, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
557 of 665 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Front Door Ice Wouldn't Work And Air Going Into Freezer
Thanks to the pictorial diagram, I was able to order correct parts. It was just a matter of removal of broken parts and replacing them. Ice maker now working and air is no longer getting into freezer which was freezing up ice maker. Thanks for timely delivery, now I am able to use ice dispenser, which I haven't used for long time. Thanks
Parts Used:
Ice Door Kit Dispenser Door Pin Control Bracket Micro Switch
  • BILL from BATESVILLE, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
492 of 591 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
track of the pan become broken
Buy a new crisper pan,slide out old one ,slide in new one
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • Darrell from Cedar Bluff, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
422 of 442 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator door was not closing all the way if not pushed shut.
Remove the top hinge cover. Removed the top hinge support. Lifted the door from the bottom support. Old door cams were worn completly flat. Replaced the lower door cam and closing cam use a little vasalene for lubricant on the cam surfaces. Placed the door back on the lower hinge support. Replaced the top hinge support. Door is closing great now.
Thanks for the quick part deliver.
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • Norbert from Sugar Land, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
392 of 413 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drawer guides broken
Simply pulled out old drawer and replaced with new one. This broken drawer really bothered my wife so this simple repair earned me alot of points at home. Lord knows i can use all the extra points i can get. Thanks for the quick shipment of the part. 2 days from time of call to part on my door step. Thanks again
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • Paula from Chesterfield, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
316 of 409 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When the remote water was turned on, water was pouring onto floor from rear of refrigerator
First I unplugged the fridge, then using the socket set I removed the cardboard shield from the lower rear of the refrigerator. I located the leaking water from a cracked solenoid water valve just inside the lower cavity directly behind the water intake line. Removing the valve was a snap - most of the valve plastic compression couplings unscrewed and came off. The metal compression fittings required an adjustable wrench and a pair of pliers to hold the solenoid unit steady. A couple of hex nuts kept the solenoid bolted to the refrigerator frame and came off easily with the socket. Two simple push-on electrical plugs came right off just by pulling on them. The new valve unit wasn't exactly like the original one. It had push-on instead of compression water fittings and the plugs were oriented differently. I recommend studying which water lines entered which port on the valve because I was a little unsure after I took the old one apart (whoops). After figuring out how to put it pack together, the push-on water fittings were even easier, and the unit was scewed back into place on the fridge frame. The electric plugs have different sized contacts so you can't mix them up. I put the cardboard shield back on. Viola!
Parts Used:
Water Inlet Valve
  • Mark from Wolfeboro, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set, Wrench (Adjustable)
214 of 248 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker would not stop making ice.
First, I tested the ice maker "switch" that actually just covers the beam that regulates the ice maker. In the "off" position, it still made ice. Then, I removed the three screws on the cover over the transmitter and disconnected the circuit board at the wire connector. It stopped. After ordering and receiving the new transmitter and receiver boards, I replaced both boards. They are located on either side of the freezer compartment under panels held in place by three screws. Probably saved 150 to 200 bucks.
Parts Used:
CNTRL-ELEC
  • Vince from El Cajon, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
191 of 214 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would't fill with water
I first read your forum which was extremely helpful! I checked the continuity of the electromagnetic valve and got a 0 reading on the ice fill valve. The valve next to it which is for the water in the door had a 300ohm reading on my meter. This meant there was a broken wire somewhere in the coil which confirmed the valve was bad. I tried to get the part locally but was told it was on back order! Ordered it thru Part Select at the regular shipping rates and to my surprise it arrived the very next day!
The valve was the new style where you push in the tubing until it locks. I carefully trimmed each tube square with a sharp razor knife, the old valve used plastic compression fittings which had to be cut off.One of the inlet tubes was smaller than the opening on the valve. I then noticed that there was a reducer in the box that snapped into place making the line a perfect fit! Even though the inlet valve looked different than the original it was an easy installation. After replacing it, I had ice again! Totally impressed with the service and how quickly they shipped the parts on the same day! I will never again run around town trying to find parts! Thanks to all of the hard working employees at Part Select!
Parts Used:
Water Inlet Valve
  • Jerry from Cooper City, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
167 of 183 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Parts Used:
Bi-Metal Defrost Thermostat
  • Cathy from Winter Park, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
154 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Door quit closing on it's own......
Door quit closing on it's own......

** Order the following from www.partselect.com

Lower Door Closing Cam -- Part Number: PS323495

Upper Door Closing Cam -- Part Number: PS327641




1. 1/4 drive socket and standard socket
2. On top of door .... remove black plastic bracket cover on top of hinge
3. Have someone hold the frige door in place
4. On top of door .... remove 3 screws that hold the hinge onto the frige..... at this time, door will be loose
5. Lift door up and off the bottom hinge.
6. sit door on the ground. Tilt door at an angle for access to the "cam"
7. On frige, at the bottom, use socket to remove one screw that holds the old "bottom" cam in place..... then replace with new one.
8. While door is tilted, use socket to remove one screw that holds the "top" cam in place.
9. You will need to gently pull this cam out.... shouldn't take too much effort though.
10. Replace with new cam.
11. put door back on hinge
12. At top of frige, reinstall 3 screws
13. Reinstall plastic cover.
14. Voila, you're done

Thanks PartSelect !
Parts Used:
Lower Door Closing Cam Door Cam - Black
  • T.w. from Batesville, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
140 of 153 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker stopped working
With socket wrench un-screwed the 3 screws and pulled out the ice maker assembly.

Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)

However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part.

Unscrewed the motor assembly (3 screws) with phillips head screw driver.

Screwed in the new unit.

Placed ice maker back into location and tightend the bacing srews.

1 hour later ice was falling!
Parts Used:
Icemaker Control Assembly
  • Robert from Port Washington, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
135 of 154 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
where ic e dispencer spring is held to door broke at mold
after ordering ice dispencer repair kit, and removing the outer parts found out that the problem was the ice dispencer door shell . this part is no longer available.It seems to me that if whirlpool wants to have return customers they have to stand behind the product. Well I made a L bracket and drilled a hole to to recieve the spring keeper and glued this to the housing and used a 3 1/12"finishing nail as the pin all works fine
Parts Used:
Ice Door Kit
  • helen j from murrells inlet, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
123 of 142 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Warm Air Getting Into Freezer
Patience is a virtue. The kit really works. 1st, lift the front plate of the ice dispencer by placing a flat head screw driver into the two slots at the bottom of the panel. When the panel is lifted up slightly at the bottom, push up on the panel to remove it. Careful not to break panel and the wires attached. Next, remove the wiring panel by removing the two screws on left and right sides. Then, unplug the old black ice cover from the wiring panel (this is the heating plug that you will nolonger need). Next, remove the parts and replace them with the parts in the kit, noting where each part comes from, etc. All parts in the kit are necessary and should be used. Some of the replacements need trial and error. Patience will be important. Also needed is a person that loves to solve problems, especially because the kit does not come with instructions. But the kit definitely works!
Parts Used:
Ice Door Kit
  • David from Chesterfield, MO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Socket set
109 of 132 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water slowly leaking from fill tube- overflowing ice tray
unplugged fridge, turned off water supply, disconnected water supply line (towel to catch drainage). remove cardboard lower panel from back of fridge. remove 2 bolts holding existing water inlet valve assy to fridge. Disconnect 2 electric plugs from assy. water lines disconnect using push/pull method (mark where they go). If any water tube line has any surface imperfections trim off a small length of line using a razor knife (cut tubing perpendicular (or "square" )on the end. I had to remove small unused part from the new water inlet valve assy. Insert the 3 water lines to the correct spots: push them on,fully, give a tug to make sure they are connected fully. Reattach the 2 electrical plugs.Bolt the unit back in place. I connected the water & plugged it in, filled about 10 glasses of water and made sure an ice cycle ran, to check for leaks (none found). I cleaned off some of the dust on the back of the fridge, reattached the cardboard lower piece. and listened to the sweet sound of Ice filling, and not my wallet emptying to the service man!!
Parts Used:
Water Inlet Valve
  • Michael from Franksville, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
101 of 109 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!