Clicking from underneath the fridge, and compressor engaging only intermittently

  • Customer: Michael from Manvel TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 160 of 195 people found this instruction helpful
I diagnosed the problem as a bad relay. I detached the two sets of wires leading to the relay and compressor, then pulled the relay off the compressor. It rattled and small bits of detritus fell out from inside of the relay. The new relay came the next day. It did not rattle. It was identical and I simply did the reverse to reinstall.

inconsistent compressor and condensor fan operation

  • Customer: Steve earney from Brooks GA
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 121 of 124 people found this instruction helpful
Compressor start relay would cycle several times before compressor would come on. Replaced start relay and defrost timer assy. Operated more consistently however not completely reliable. Ice would begin to melt. Noticed that if you would cycle the temperature control the compressor would start again and operate for several hours then not cycle again. Jumpered temp control and operation was continuous and reliable. Replaced cold control thermostat. Operation now normal. Suspect high resistance in switch caused start relay and timer contacts to arc. Small amount of carbon noticed under temp control...

Refigerator door was not closing all the way if not pushed shut.

  • Customer: Norbert from Sugar Land TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 113 of 116 people found this instruction helpful
Remove the top hinge cover. Removed the top hinge support. Lifted the door from the bottom support. Old door cams were worn completly flat. Replaced the lower door cam and closing cam use a little vasalene for lubricant on the cam surfaces. Placed the door back on the lower hinge support. Replaced the top hinge support. Door is closing great now.
Thanks for the quick part deliver.

Both freezer and refrigerator stopped cooling

  • Customer: Laune from Front Worth TX
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 108 of 129 people found this instruction helpful
Compressor Start Divice kit, I took off back lower panel with the 1/4 inch nut driver, on the compressor their was a wire hook that held the starter in place used my plyers to unhook, pulled the unit off plug the new unit in reappled the clip it was so easy I had to exame it severl to time to make sure that was all their was to it. put the cover back on and turn the refrigerator on and it has work great, I did not install the Bi-Metal Defrost Thermostat it was not needed.

My refrigerator stopped cooling and the freezer section stopped freezing

  • Customer: garth from forest lake MN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 101 of 109 people found this instruction helpful
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!

Seven year old condenser fan was making noise when it was running.

  • Customer: Josue from Jacksonville NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 93 of 98 people found this instruction helpful
The process to repair was very simple, I removed the back of the refrigerator to expose the motor area. I then removed three screws that held the condenser motor in place. once it was loose I detactched the electrical harness and removed the old motor. I then placed the new motor in place and secured it with the screws and reattached the new electrical harness that came with the new part. Once completed I reviewed it to make sure I didn't miss anything. I then replaced the cover over the motor area and enjoyed my success in repairing my own appliance with no added cost for labor, which would have been expensive I'm sure. The part purchased came with clear and consice instructions very easy to follow.

Fridge was getting too warm, ice buildup on coils.

  • Customer: Cathy from Winter Park FL
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 76 of 84 people found this instruction helpful
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.

The compressor would shut down and not restart unless you tapped the temperature knob which i did for about 3 weeks before ordering this part

  • Customer: michael from clarksville TN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 57 of 61 people found this instruction helpful
Was pretty simple just take the knobs off pull off the face plate remove a few screws and drop the whole shelf down. then a few more screws down the side to the back of the fridge. Pull the sensor wire out of some styrofoam and pull off the plastic coating and slide it over the new one and install it in reverse order from taking it out. Works great now and i have ice everyday :)

Refrigerator Door quit closing on it's own......

  • Customer: T.w. from Batesville AR
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Socket set
  • 36 of 38 people found this instruction helpful
Door quit closing on it's own......

** Order the following from www.partselect.com

Lower Door Closing Cam -- Part Number: PS323495

Upper Door Closing Cam -- Part Number: PS327641




1. 1/4 drive socket and standard socket
2. On top of door .... remove black plastic bracket cover on top of hinge
3. Have someone hold the frige door in place
4. On top of door .... remove 3 screws that hold the hinge onto the frige..... at this time, door will be loose
5. Lift door up and off the bottom hinge.
6. sit door on the ground. Tilt door at an angle for access to the "cam"
7. On frige, at the bottom, use socket to remove one screw that holds the old "bottom" cam in place..... then replace with new one.
8. While door is tilted, use socket to remove one screw that holds the "top" cam in place.
9. You will need to gently pull this cam out.... shouldn't take too much effort though.
10. Replace with new cam.
11. put door back on hinge
12. At top of frige, reinstall 3 screws
13. Reinstall plastic cover.
14. Voila, you're done

Thanks PartSelect !

Refrigerator was not cooling properly.

  • Customer: Eddie from Gretna LA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers, Socket set
  • 34 of 36 people found this instruction helpful
I removed both plastic knobs from assembly faceplate. Then I loosened the screws holding thermostat housing to upper cabinet of fridge. Following this step, I loosened the screws of the thermostat to remove it. Next was the removal of the plate and vent pieces holding the thermostat wire sleeve in place. After removal of thermostat from sleeve; all steps were reversed and unit was up and running normal (cooling) with no problems. "Ahh, it's nice to have cool again "

Lights inside refrigerator not working

  • Customer: Clint from Rayville MO
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 36 of 43 people found this instruction helpful
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.

No Cooling

  • Customer: Gregory from Portland OR
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 33 of 36 people found this instruction helpful
I noticed the fan was running but not the compressor, they are wired in series meaning the compressor should also have power and you should hear the compressor. Could not hear compressor coming on, removed the white relay attached to the side of the compressor and could hear loose pieces shaking in relay. Ordered new relay and plugged it in, took less than five minutes. Very Easy. Thank you Partsselect

woke up to very harshburnt wire smell cominf from the back of the refrigerator

  • Customer: Don from New Port Richey FL
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 30 of 35 people found this instruction helpful
I found many helpful tips and pdf instructions online, removed the back of the refrigerator can remove the compressor relay. I ordered a new compressor relay or start relay kit, followed the instructions and put the new compressor relay in. Refrigerator is working great...

REFRIGERATOR WASN'T COOLING,EVAPORATER COIL FREEZING UP

  • Customer: Robert from Doral FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 28 of 35 people found this instruction helpful
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment.
The bi-metal switch was right there in plain view. There are two colored wires that come out of the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good

refrigerator stopped cooling, otherwise fine

  • Customer: Roger from Bethesda MD
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 27 of 33 people found this instruction helpful
Well first of all, I was afraid that the compressor was shot and I'd need a whole new refrigerator (ack $1000!!!). After googling/reading, I figured out that the starter relay mounted on the compressor was burned out. (loud click as thermal cutout shuts down compressor.) So, I ordered a replacement part, overnight shipping. Unfortunately, this was on a Friday night, so I had to figure out how to keep the fridge cold all weekend (til Tuesday). I'd already moved frozen stuff to a chest freezer, but the inside of the fridge compartment was now nearly warm at this point, so I got 10 lb of dry ice. That got things cooled down initially. Well, turns out that with a short piece of wire, you can momentarily jump across the terminals of the relay and kick start the compressor. It then runs until either the defrost cycle stops it or the thermostat kicks it off. Anyway, all weekend, every six hours or so, I turned off the fridge for a minute to cool down the overheated, stalled compressor, then turned it on and jumped the terminals to start it up. Kind of a pain, but saved lots of food. Overall, the $30+$30 (shipping) for the part saved me from having to get a new refrigerator, so I'm quite pleased. I've used Part Select many times now. Very fast service and shipping, great website/database. I shop around and every time end up buying from them again.