Refrigerator was getting warm

  • Customer: Mack from Los Banos CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 0 of 0 people found this instruction helpful
Unplugged it for a day listened to the ice melting on the inside and plug it in again. Decreased the temperature settings and it now seems to work fine. I will save the part in case I ever need it in the future.

Solid ice on Evaporator coil

  • Customer: PRAKASH from PISCATAWAY NJ
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 0 of 0 people found this instruction helpful
With service sheet, Enter service dagnostic mode, NO-6 is Desrost heater / Bi-metal Component status indicator shows 02 , it means Bi-metal is open, It should read 01,It's cover with Ice ( bellow 32 Dig. F )Mostly it open at 50 dig. F, To replace remove lamp cover and lamp + six hex screw with 1/4" nut driver, pull back cover ( with commen requirement to turn of power and deice the evaporator coil )out, bi-metal element is top at enterance of coil,cut both wire near bi-metal, join new bi-metal with wire nut or Insulated wire Jointer, Tape jonts proper,do neat work no hanging wire, Replace back removed parts back,Turn power back

The refrigerator would not defrost and would freeze up and no longer cool.

  • Customer: Mike from Frankfort IL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 0 of 0 people found this instruction helpful
Turn off power to the frig. Remove the shelves and back brackets from the freezer, then with a 1/4" nut driver remove the nuts holding the rear metal panel in place. Once removed the defrost thermostat is right in front of you. You will have to clip the wires from the old t-stat because they are in a harness. Once clipped, strip the wires back, wire in the new t-stat, add wire nuts and put it all back together. Very easy job to do, works great. Thanks Parts Select, Mike.

fridge too warm

  • Customer: mike from ROSCOE IL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 0 of 0 people found this instruction helpful
remoove all the food and shelves out from the freezer section, remoove the light bulb lens ( 1 phillips screw) remoove light bulb, take out 6 srews on the back panel then slide out through the top with a slight bending curve motion, the bimetal thermostat will be clamped to the evaporator inlet, ( just after the cap tube) snap it off, then cut the wires about 2 inches from the stat, strip the ends about a quarter inch with wire strippers, same on the new stat, then use 16 or 18 gauge butt splices and crimp them , then reassemble in reverse order.

Freezer OK. Refrigerator Not Cooling.

  • Customer: Donald from Kissimmee FL
  • Difficulty: Easy
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 0 of 0 people found this instruction helpful
Followed recommendations from others but went with most likely by percentage = Defrost Timer Kit. Did not solve issue. Then went with Bi-Metal Thermostat and that did not fix the problem. Tested the thermostat as recommended on line and old part was bad, new part OK. Then I saw on line that I should have listened for Fan operation. I checked and found the fan Motor to be defective. Replaced the motor and Refrigerator worked fine. Both the Motor and Bi-Metal Thermostat were required. Should have checked fan operation first.

refrigerator and freezer would stay frozen.

  • Customer: Jack from Poplarville MS
  • Difficulty: Really easy
  • Time to Complete: More than 2 hours
  • Tools Required:
  • 0 of 0 people found this instruction helpful
I shut the unit off for about ten hours and when I turned it back on and set the temperatures for the freezer and refrigerator it has been working great.I will keep the part in case it happens again.

I feel like McGyver!

  • Customer: David from Los Angeles CA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Socket set
  • 0 of 0 people found this instruction helpful
Hi, this was an easy repair job. And, after I was done I felt like McGyver. It took me about 1 hour. The hardest part was getting ice maker's power source disconnected. That was tricky; you have to remove the housing that covers the power connector.

ice maker dump tray was broken

  • Customer: Donald from White Lake MI
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set, Wrench set
  • 0 of 0 people found this instruction helpful
removed ice maker took motor assembly off the end of ice maker, and installed the new part. this was pretty easy because I have taken it apart before. But this is not a hard job for a novice.

ice maker would not dispense ice, worn shaft

  • Customer: William from Rosenberg TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Pliers
  • 0 of 0 people found this instruction helpful
removed the ice container, remove the two screws that hold in the shaft and seal. use pliers to remove worn out shaft, drop in the new shaft and seal reinstall the cover with the two screws and your done. took maybe 5 minutes start to finish.

Ice dispenser would not spin, shaft worn down

  • Customer: Jon from Coppell TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Socket set
  • 0 of 0 people found this instruction helpful
The hexagonal shaft had been worn down so that the edges no longer could be gripped by the teeth on the ice dispenser bucket. Remove the the two screws underneath the bucket. Use pliers (if needed) to pull out ht sold shaft. Slide in the new shaft, and twist until it drops into place. Replace the two screws and you're all set!

Ice maker would not send ice through the dispenser

  • Customer: jonathan from austin TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 0 of 0 people found this instruction helpful
Opened the freezer door. Removed the ice bin from the freezer compartment. Removed with a nutdriver the two screws holding down the shaft holder (the triangular white plastic piece). Removed the shaft holder and the circular seal underneath. Pulled the hexagonal metal shaft up and out of the dispenser motor. Installed new circular seal and reinstalled the plastic shaft holder, etc..

Refrigerator stopped working

  • Customer: Howard from El Sobrante CA
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 0 of 0 people found this instruction helpful
The refrigerator stopped working and temperatures were rising. After inspection, noticed that the compressor is not running and condenser fan not running. I ordered the inverter box and replaced the old one. Compressor started to run but condenser fan still not running. Compressor was getting hot while freezer temperature reduced to some degree. Cleaned condenser with compressed air, connected condenser fan directly to 110VAC. Refrigerator runs normally. Burning of the inverter box may be preventable. We did notice that the freezer portion of the door frame getting hot for over 3 months. This is an indication that the condenser does not provide sufficient heat dissipation. This in turn made the compressor hot and melted away some components in the inverter box which is located next to the compressor. A thorough cleaning of the condenser made the freezer door frame stay slightly warm but not hot. This condition keeps the compressor running at normal temperature. I still need the main controller which is discontinued to automatically control the condenser fan. So far the fan runs all the time and uses a bit more electricity than necessary.

icemaker stopped working

  • Customer: Thornton from Highlands NC
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 0 of 0 people found this instruction helpful
I did not have voltmeter to test for problem. Internet sites suggested the most common problem is the circuit boards--a sender and a receiver which detect when the ice bucket is full. I could only buy as a pair (about $94). I removed two screws of cover of receiving unit, detached the coupler, replaced the circuit board. Icemaker now works. The sender was obviously still good.

Power Surge fried the ice maker control boards.

  • Customer: Dennis from Powell OH
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 0 of 0 people found this instruction helpful
I was ready to spend the $$$ on a repair person when my wife (smart woman) suggested I go on line to see if we can fix it ourselves. I (luckly) found your company and your website made it easy to find the right part plus as an extra bonus you had a video that showed how to switch out both control boards. To top it off, the package came so fast ( the next day - even with standard shipping ) I did not think it was the parts. 10 or so minutes with a Phillips screwdriver and we were back in business. THANK YOU ! ! ! !

Ice Maker sensor did not see full ice bin.

  • Customer: Mark from Woodstock IL
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 0 of 0 people found this instruction helpful
Unplug the Unit first! Unscrewed the sensor covers on both sides. Snap off the old, snap on the new. Replace the covers and screws.