Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID

  • Customer: James from Ringoes NJ
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 16 of 20 people found this instruction helpful
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat. Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.
-James

broken meat and vegatable draw

  • Customer: douglas g. from roanoke VA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 15 of 17 people found this instruction helpful
a simple replacement

refrigerator would not stay cold

  • Customer: Allan from Allen TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 16 of 20 people found this instruction helpful
The wife found if we tapped the knob for the cold control the appliance would turn on. Upon further inspection I found what looked to be carbon particles under the part. I found the part easily with partselect.com, ordered it, installed it and its like we have a new appliance.

greezer started to thaw and would not refreeze

  • Customer: Christopher from Redmond WA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 16 of 20 people found this instruction helpful
tested thermostat and defrost time but both tested as working...called a repairman who came in and said they were both working...got annnoyed for not trusting myself. Repairman did say that he had seen defrost timers simply slow down, allwoing them to tesat as good but not actually working correctly. I ordered both the thermostat and the timer to cover all bases...actual replacement was simple.

Smelled Electrical Burning / Smoke

  • Customer: Stephen from Holt MI
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 21 of 36 people found this instruction helpful
Removed cardboard back from refrig. Found source of smell/burn. Removed part. Ordered several replacement parts as the diagram was not clear as to which part would be needed. New parts arrived, matched with old. Cleaned carbon from contacts, installed new part. Cleaned dust from refrigeration coils, installed back. Returned unused parts.

The light switch on the refridgerator broke - no light.

  • Customer: David from Albany OR
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 18 of 27 people found this instruction helpful
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!

refrigerator door wouldn't remain closed

  • Customer: Thomas from Fairfax VA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 15 of 19 people found this instruction helpful
The plastic lower door closing cam was worn down. Replacing it was very simple: remove the top door hinge by unscrewing three nuts; lift the door off the lower hinge; unscrew and remove the lower door hinge; screw the new plastic lower door closing cam on to the new door hinge; screw the new lower door hinge; lift the door back on to the lower door hinge; screw the top door hinge.

Fridge side freezing everything.

  • Customer: David from Murfreesboro TN
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 13 of 14 people found this instruction helpful
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control box to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.

drawer broke from kids overloading it.

  • Customer: jonathan from sugar hill GA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 13 of 15 people found this instruction helpful
Pulled out the old drawer and put in the new.

Refrigerator door failing to close without being pushed shut

  • Customer: Kenneth from Greeley CO
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Pliers
  • 13 of 15 people found this instruction helpful
Replaced upper cam piece on bottom hinge and also replaced pivot thimble on upper hinge.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.

compressor not running

  • Customer: james from islamorada FL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 14 of 18 people found this instruction helpful
found power up to current relay but not to compressor. removed the old current relay and installed the new relay and the compressor started running and the refrigerator works fine now.

The fan wasvery noisy.

  • Customer: Tracy from Coppers City Bottom WV
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 12 of 13 people found this instruction helpful
Removed six screws from cover in the back of the freezer. Removed old fan . Removed power wires from old motor. Unclipped old motor from the mounting bracket. Replaced old motor and reversed the rest of the parts. Done

compressor clicking on and off, not cooling

  • Customer: Frank from lincoln CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 12 of 14 people found this instruction helpful
After unplugging the appliance I removed acess cover on back of fridge with a screwdriver, pulled the overload start device straight off the compressor, unplugged the red/ white factory pre-terminated conductors and replaced the bad start device. Took about 2 minutes. You must remove as much of the dust and lint from condenser element to keep this from happening again since heat will build up and fry the overload again.

Noise coming from defrost timer

  • Customer: Thomas from Pottstown PA
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 11 of 13 people found this instruction helpful
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.

Refrigerator quit refrigerating

  • Customer: William from Hudson FL
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Screw drivers
  • 13 of 19 people found this instruction helpful
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
All Instructions for the 10641519100