freezer would freeze then thaw

ApplianceGeneral Electric Refrigerator

Model

Level of DifficultyReally easy

Time to do repairLess than 15 mins

Age of Appliance1 - 4 years

Tools Pliers
Nutdriver

scott From washington, NC

May 02, 2008

1 out of 1 people found this instruction helpful

diagnosis, fan would run more than normal, compressor would only come on sometimes, check line voltage to the mother board (yes !!! a mother board with a relay for the compressor built onto it )! check the switched voltage out to the compressor. If a/c 115 in but no a/c 115 out while the fan is on replace the mother board. Remember this is a LIVE VOLTAGE TEST, BE CAREFUL HOW AND WHAT YOU TOUCH YOUR LIFE IS NOT WORTH SAVING A REPAIR BILL !!!
I suppose if if went long enough in this condition the result would be fan runs a lot but it does not get cold.
Hope this helps
God Bless
Captain Scott Cousins