ApplianceGeneral Electric Refrigerator
Model
Level of DifficultyReally easy
Time to do repair15 - 30 mins
Age of Appliance1 - 4 years
Tools Screw drivers
0 out of 1 people found this instruction helpful
1. Remove back cover from frig2. Remove Double Outlet Water valve from frame3. Place towel under valve, remove supply line to filter4. Cut black and clear lines next to valve, ensure a smooth cut5. Slide new connectors onto lines, press lines into valve firmly, make sure they slide in all the way6. Slide connectors into valve locking into place7. Re-connect filter supply line and re-connect valve to frame making sure lines are in the proper place8. Replace back cover of frig, do not over tighten screws