After 5 years the pump gave out, but much cheaper to replace than buy new ice maker

ApplianceGeneral Electric Ice Maker

ModelZDIS15

Level of DifficultyA Bit Difficult

Time to do repair30 - 60 mins

Age of Appliance5 - 10 years

Tools Pliers
Socket set

Drew From Birmingham, AL

Dec 11, 2013

1 Turn off ice maker and drain water reseviour (cap at bottom of reseviour) 2. Remove internal ice storage door to give you more working room 3. Remove water resevious (two screws on either side of reseviour) and disconnect plastic tubing in reseviour 4. Remove cover shield at top that covers the ice cutting mechanism (two screws at bottom of cover 3. Remove cover shield covering pump (1 screw) 4. Remove small plastic tubing on side of pump (this part is a little tricky) 5. Remove the three screws holding pump to unit (one at back and two on the side (one in front of pump and one in back of pump) 6. Disconnect power supply to pump 7. Remove pump and replace

Help other customers find the most helpful instructions.

Were these instructions helpful?

Diagrams and Parts List for this repair

Part PhotoPart DescriptionPriceAvailability

Circulation Pump with Motor

Part Number: PS332830

$198.79
In Stock