Part Location Diagram of WR51X10031 GE Defrost Heater with Thermostat
See part 230 in the diagram
( Grid squares measure 1x1 inch )
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

customerservice@partselect.com

Defrost Heater with Thermostat WR51X10031

★★★★★
★★★★★
3 Reviews

Rated by 6 customers 

Really Easy 

1- 2 hours 

Ratings submitted by customers like you who bought this part.

$ 131.08
  On Order
PartSelect Number PS303762
Manufacturer Part Number WR51X10031
Manufactured by GE
Product Description

Defrost Heater with Thermostat Specifications

This part assembly has 2 functions: The defrost heater keeps the cooling coils from frosting over and the thermostat senses that the heat near the cooling coils has reached the desired temperature.
How Buying OEM Parts Can Save You Time and Money

How Buying OEM Parts Can Save You Time and Money

Troubleshooting
This part fixes the following symptoms:
Fridge too warm | Freezer section too warm | Freezer not defrosting
This part works with the following products:
Refrigerator.
This part works with the following products:
General Electric, Kenmore, Hotpoint.
Part# WR51X10031 replaces these:
AP2071523, 773802, WR51X10031
Back to Top
Customer Reviews
Average Rating:
★★★★★
★★★★★
3 Reviews
5.0
Filter By Rating:
  • 5 Stars
    3
  • 4 Stars
    0
  • 3 Stars
    0
  • 2 Stars
    0
  • 1 Star
    0
Sort by:
  • 1
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
  • 1
Customer Repair Stories
 Average Repair Rating: 3.2 / 5.0, 6 reviews. What's this?
Sort by:
  • 1
Sorry, we couldn't find any existing installation instruction that matched.
Automatic Defroster was not working and it caused the unit to not stay cool.
After removing the 4 screws from the inside back panel of the freezer and setting a small heater with fan, on a small metal step ladder for about twenty minutes to defrost the freezer coils, it was a snap to remove the two small screws holding the burned out heater harness defrost assembly, and unplugging the wire harnesses to replace the burnt unit with a new one. Actual hands on time was about 5 minutes. Difficulty level, well... my wife did it and she is not mechanically inclined.
  • Daniel from CRIDERSVILLE, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old wires wouldn't come out.
First of all I'm 76 years old. The same thing happened 5 years before and I had a service man out to fix it. I did what he did. Unplug the heater from the harness and plug in the new heated.
  • Richard from Shannon, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not defrost
Removed the internal cover and used a hair drier to defrost the evaporator. Unpluged the conectorto the harnes. Placed new part in and pluged it in, replaced cover and tested.
  • William from Raytown, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Fridge Was Not Defrosting
The repair stories for this part are helpfull. The only problem I came accross was figuring out which part I needed to order. The parts diagram only showed one part labled 230, but when I used the drop down box to order the part there were 2 parts labled 230 for 2 diffrent prices. I called ge customer care and found out the less expencive part listed as 230 does not come with the wires etc. . The more expensive piece has the wire harness and every thing needed. I went with the more expensive part and it was a snap to install. . . .
  • John from north Bellmore, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Heater coil in frost-free freeze side fail (second time)
Remove freezer contents, shelves, and interior back-panel. Melt all ice on freezer coolang coil with hair dryer. Be careful not to touch to coling fins on the coils with the hair dryeer since they damage easily. Unplug the old heater coil wire harness at the top of the coils. Gently remove the thermocouple clipped to the top coil. Gently remove the wires leading down to the heater coil at the bottom-back of the freezer. Remove the old heater by removing the two mounting screws. Install new heater by reversing the steps above.
Good luck.
Ps. When the heater coil fails the result is, both the freezer and refridgerator sides get warm and food spoils. A good indicator to watch for is frost building up in the freezer on the interior back-panel. I taped cheap thermometers in both side to help mointor the temperature in case it happens again.
  • Keith from Osceola, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
29 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the defrost heater went out cause my freezer to freeze up I changed out the heater and it was simple and repaired
I had to defrost the freezer again before I could even start the replacement We unplub the old wiring harness took out two screws removed the old heater put in the new one replaced the srews and reconnected the harness we were done.
  • DARWIN from HECTOR, AR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
  • 1
Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

1 question answered by our experts.
Sort by:
  • 1
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
JR
May 2, 2018
I am trying to fix this refrigerator what should the temp be in side the freezer and in the frig. Right now it is 32 in both? I am going to replace the defrost timer and see if that helps..
For model number TFX20JRBKWW
PartSelect logo
Hi Jr, Thank you for the question. The refrigerator temperature at or below 40° F (4° C). The freezer temperature should be 0° F (-18° C). Hope this helps!

Was this helpful?
Thank you for voting!
  • 1
Model Cross Reference
This part works with the following models:
PartSelect Number: PS303762
Manufacturer Part Number: WR51X10031
Brand
Model Number
Description
Kenmore
36348042894
Refrigerator
Kenmore
36348042896
Refrigerator
Kenmore
36348042897
Refrigerator
Kenmore
36348047894
Refrigerator
Kenmore
36348047896
Refrigerator
Kenmore
36348047897
Refrigerator
Kenmore
36348252894
Refrigerator
Kenmore
36348252896
Refrigerator
Kenmore
36348252897
Refrigerator
Kenmore
36348257894
Refrigerator
Kenmore
36348257896
Refrigerator
Kenmore
36348257897
Refrigerator
Kenmore
36350221000
Refrigerator
Kenmore
36350222000
Refrigerator
Kenmore
36350227000
Refrigerator
Kenmore
36350232000
Refrigerator
Kenmore
36350237000
Refrigerator
Kenmore
36350242000
Refrigerator
Kenmore
36350247000
Refrigerator
Kenmore
36358042894
Refrigerator
Kenmore
36358042896
Refrigerator
Kenmore
36358042897
Refrigerator
Kenmore
36358047894
Refrigerator
Kenmore
36358047896
Refrigerator
Kenmore
36358047897
Refrigerator
Kenmore
36358062894
Refrigerator
Kenmore
36358062896
Refrigerator
Kenmore
36358062897
Refrigerator
Kenmore
36358067894
Refrigerator
Kenmore
36358067897
Refrigerator
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

Contact Customer Service