The cold water valve was not closing completely and the tub would fill will water after several hours.

ApplianceFrigidaire Washer

Modelatf6000fs1

Level of DifficultyEasy

Time to do repair1- 2 hours

Age of Appliance1 - 4 years

Tools Pliers
Screw drivers

Eugene From Crestwood, MO

Mar 19, 2013

out of people found this instruction helpful

I shut off the water supply and started a cycle to release the pressure on the valves. Unplugged the power. Removed the top by unscrewing two screws on the back. Unscrewed the water lines and snapped off the plastic retainer for the water lines and overflow tube. Disconnected the wires to the red, green and blue valves, as well as the small black sensor on the side of the valve assembly. I had to unlock and partially disconnect the overflow tube to allow me access to one of the mounting screws. Removed the other mounting screw and separated the valve assembly by pulling it firmly. I put a little silicone grease on the two rubber mounting grommets and inserted the new valve assembly and re-assembled screws, wire harnesses. Replaced the top and screwed it down.

Help other customers find the most helpful instructions.

Were these instructions helpful?

Diagrams and Parts List for this repair

Part PhotoPart DescriptionPriceAvailability

Water Inlet and Dispenser Valve

Part Number: PS1145692

$49.57
In Stock