Would sometimes heat initially and then no heat at all.

ApplianceGeneral Electric Dryer

ModelDBVH512GF1WW

Level of DifficultyEasy

Time to do repair30 - 60 mins

Age of Appliance1 - 4 years

Tools Nutdriver
Screw drivers

Jamie From Mission Viejo, CA

Oct 17, 2012

First, removed pedistal base (4 hex screws), removed top panel (3 screws, plus 2 screws), removed right side panel (several screws in multiple locations (bottom, top, rear and front), removed coil strap (2 screws), unplugged wire harnesses and replaced coils, reinstalled coil strap, right side panel, top panel and pedistal. Dryer is now working great.